Advanced Operations: Process-Control
4 - 21
Standard Turntable Power Washer v. 4.0
The MART Corporation
5. Steam-Exhaust Timer
The steam-exhaust timer controls the length of time that the automatic steam exhaust
(ASE) operates after the end of the wash or rinse cycle. The timer is located inside the
electrical control panel. Refer to Fig. 4-2.
How the ASE cycle actually works depends on your washer's configuration:
ARC (optional)
If your washer is equipped with the optional automatic rinse cycle
(ARC) the automatic steam exhaust (ASE) cycle removes steam
from the washer cabinet:
·
During the wash cycle
·
During the optional automatic rinse cycle (ARC)
·
For the ASE timer-set period of time
after
the automatic
rinse cycle (ARC) cycle has completed
No ARC
If your washer is
not
equipped with the optional automatic rinse
cycle (ARC), the automatic steam exhaust (ASE) cycle removes
steam from the washer cabinet:
·
For the ASE timer-set period of time
after
the wash cycle
has completed
5.1. Setting the ASE Timer
The steam exhaust timer is an adjustable 0-10 minute timer.
Fig. 4 - 9: Automatic Steam Exhaust (ASE) Cycle Timer Increments
Wash Delay
Timer (0-1min)
Rinse
Timer (0-10min)
Ase Timer (0-10min)
Temperature
Controller
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...