4.5. Troubleshooting
This section contains tables on the following problems:
·
Peristaltic pump does not pump
·
Concentration cannot be maintained
Problem:
Peristaltic pump does not pump
Check This:
Probable Cause(s)
Pump tubing
Cracked (move or replace)
Barrel
Empty of concentrate (replace)
Power
Not
ON
Fuses
Not intact (remove and measure continuity)
Overloads
Not all of them are re-set
Probe
Dirty (clean)
Set point
Too high (set below readout level)
Pump motor
Defective (replace)
Fig. 7 - 13: Troubleshooting: Peristaltic Pump Does Not Pump
Problem:
Conductivity cannot be maintained
Check This:
Probable Cause(s)
Peristaltic pump tubing
Cracked (move or replace)
Barrel
Empty of concentrate (replace)
Conductivity controller
Set point incorrectly set
Defective
Chemical Concentration:
Wrong type of chemical
Wrong concentration recommended or developed
Concentration not proportional to conductivity
Fig. 7 - 14: Troubleshooting: Conductivity Cannot Be Maintained
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...