Installation
2 - 27
Standard Turntable Power Washer v. 4.0
The MART Corporation
The steam-exhaust pipe may exit your building either vertically or horizontally, as shown
in the following figure. This figure does not show you how to install the ASE blower unit
in the piping (see ASE Assembly Figure 2-13) rather, it represents a general view of the
two possible configurations (vertical or horizontal). You will select one of these
configurations when you install the piping and blower. Note: Install venturi such that fan
motor shaft is horizontal. Use a twist transition supplied from MART if required.
Fig. 2 - 11: Auto Steam Exhaust (ASE) Piping and Blower Installation
Configurations
Note
: Any horizontal section of steam exhaust pipe must rise by
1/2-inch (13 mm) per foot (30.5 cm) of pipe. This is necessary for
proper condensation drainage back to the washer.
Steam-Exhaust Fan
The auto steam exhaust (ASE) Venturi blower assembly is provided by MART. It comes
unassembled and must be mounted in the steam-exhaust piping. Mount blower and fan
as shown in diagrams. Do not mount fan housing below venturi blower inlet,
condensation may collect in blower housing.
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...