Installation
2 - 41
Standard Turntable Power Washer v. 4.0
The MART Corporation
5. Turn power on to the washer and test the new level by allowing the washer to
fill to the new set point.
NOTE:
It will be necessary to remove water from the washer if the new level
is lower than the old set point.
Verify that the set-point level is correct. If necessary, repeat the above steps
until the set-point level is at the indicator, plus or minus 1/8" inch.
6. Replace the cover on the float box and tighten the four screws.
NOTE: If your washer has a rinse system, once operations
have started water levels in the washer can be higher than the
set-point water level. This happens whenever the washer
automatically uses the rinse-bank for longer rinses.
To verify the correct set-point water level after operations have
started, you must allow the washer to fill to the set point. You
can check this by observing the position of the float cam
relative to the limit switches in the float box. (Refer to Fig. 1-3:
Float-Level Mechanics) If the cam is higher than the set point,
you will have to remove solution from the washer and allow
the washer to fill to the set point to check set-point water level.
Control Voltage
:
CAUTION
: This procedure exposes personnel to dangerous
voltages and the risk of electrocution. Be sure the people
performing this task are qualified and trained for the task.
1. Measure and record the control voltage to establish a baseline reading by
taking readings from #
10 wire on fuse #3
to any
neutral terminal
(on the
terminal strip at the top of the electrical control panel). Refer to Fig. 2-9 for
terminal-strip location.
2. Verify that voltage readings at each additional #10 terminal are 120 volts,
±
10%.
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...