Installation
2 - 37
Standard Turntable Power Washer v. 4.0
The MART Corporation
6.3. Power-up Procedure
NOTE
: If you need to stop the power-up procedure at any point,
press the
stop button
on the washer's control panel, or
turn off the
main power supply
.
Follow this procedure:
Preliminary Checks:
1. Is the cabinet
door closed
?
2. Is the
clock-override switch set OFF
?
3. Is the
wash timer
set to
"0"?
Supply Voltage
:
CAUTION
: This procedure exposes personnel to dangerous
voltages and the risk of electrocution. Be sure the people
performing this task are qualified and trained for the task.
1. Verify that the electrical panel door is closed and latched.
2. Turn on the building main power supply to the Power Washer.
3. Turn electrical disconnect located on the MART Washer Control Enclosure
door to the “OFF” position.
4. Open electrical enclosure door.
3. Measure and record incoming voltage available to the washer. Perform this
test at the
supply side
of the
main disconnect.
Water-Fill
:
1.
Set the
temperature controller
adjustment to "0."
This will prevent the
burner or heating elements from activating when the washer is empty of
water, should damage to the washer have occurred in shipping. Refer to
chapter
"Advanced Operations: Process-Control"
for more information.
2. Close electrical panel door.
3. Turn the electrical disconnect located on the MART Washer Control
Enclosure door to the “ON” position. If the pump/s come on, turn the
disconnect “OFF” and
immediately
contact the MART Corp. for additional
instructions.
4. Turn the 7-day clock control switch to
Bypass
.
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...