6 - 14
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v. 4.0
9. Solution-Level Control System
Use procedures in chapters
"Installation,"
"Advanced Operations: Process-Control,"
or
"Maintenance"
to correct a problem after you have diagnosed it.
Or, refer to your vendor-supplied manuals or cut sheets for instructions on correcting
problems.
This section contains tables on the following problems:
·
Water not filling reservoir
·
Water overflowing reservoir
·
System not heating
Problem:
Water not filling reservoir
Water overflowing reservoir
System not heating
Check This:
Probable Cause(s)
Float rod
Binding
Limit switches
Not connected
Dislocated
Torpedo cam
Slipped
Float
Dirty or jammed (clean)
Missing ball
7-day clock
Incorrect setting
Clock override
Not
ON
Fig. 6 - 16: Troubleshooting: Water Not Filling Reservoir, or Water Overflowing
Reservoir, or System Not Heating
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...