µSDM-1RD / µSDM-1 / µSDM-1E IOM
Mechanical Installation
426006-2304-013-B1
Lightscape Networks Ltd. Proprietary
4-21
4.4.5 Connecting the Optional Power Charger Unit
An optional power charger unit can be connected to the
µ
SDM-1 in cabinet-mounted
installations. The power charger unit provides continuous service via backup
batteries during power failures.
4.4.6 Connecting the DC Power Charger
Positive (+) wire
(Step 2a) from main power charger
Red wire (Step 3a)
to muxmain power in
Negative (-) wire (Step 2b)
from main power charger (DC1)
Negative (-) wire
from alternative power charger (DC2)
Red wire (Step 3a)
to muxalt power in
Positive (+) wire
(Step 2a) from alt power
charger
Black wire (Step 3b)
to muxmain power in
Black wire (Step 3b)
to muxalt power in
DC-1 Main Supply
DC-2 Alternative Supply
Figure
4-18: Circuit breaker box with DC power charger option
4-18 illustrates the circuit breaker and terminal block wiring for the DC
power charger option.
To connect the circuit breaker and terminal block:
1. Remove the protective cover of the circuit breaker box, located inside the
cabinet, after removing the appropriate screws.
2. Route the power charger's power cable through the appropriate opening of
the integral cabinet strain relief.
a) Connect the positive voltage wire (+) to the left terminal block on the
top side (labeled DC Source 1 on the protective cover).
Содержание mSDM-1
Страница 16: ...Introduction SDM 1RD SDM 1 SDM 1E IOM 1 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 26: ...Product Description SDM 1RD SDM 1 SDM 1E IOM 2 10 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 100: ...Acceptance and Commissioning SDM 1RD SDM 1 SDM 1E IOM 7 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 109: ...426006 2304 013 B1 Lightscape Networks Ltd Proprietary B 1 Packing List A typical SDM 1 packing list...
Страница 110: ...Packing List SDM 1RD SDM 1 SDM 1E IOM B 2 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 122: ...Connector Pin Outs SDM 1RD SDM 1 SDM 1E IOM C 12 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 132: ...Rack Installation Guidelines SDM 1RD SDM 1 SDM 1E IOM E 4 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...