µSDM-1RD / µSDM-1 / µSDM-1E IOM
Before You Start
426006-2304-013-B1
Lightscape Networks Ltd. Proprietary
3-5
3.3.1 Site Preparation
Perform a preliminary survey of the installation site to consider:
♦
System environmental requirements.
♦
Physical location of the
µ
SDM-1 cabinet.
♦
Location of the power sources.
♦
Types of interfaces used at the site (optical connectors, tributaries, etc).
3.3.2 Environmental Requirements
The following environmental conditions are applicable to the
µ
SDM-1 system and to
the site of its installation:
Condition
Compliance Reference
Electromagnetic
Interference
Complies with EN 55022/94, EN 50082-1/92 standards.
Temperature (Indoor)
ETSI ETS 300-19-2-3 Test Spec. T3.1.
Temperature (Outdoor)
ETSI ETS 300-19-2-3 Test Spec. T3.2,T3.3.
3.3.3 Physical Location
Choose the physical location of the
µ
SDM-1 cabinet, taking the following aspects
into consideration:
1. There are three types of
µ
SDM-1 multiplexers:
♦
µ
SDM-1RD supporting 8 E1 interfaces.
♦
µ
SDM-1 supporting 21 E1 interfaces.
♦
µ
SDM-1E supporting 21 E1 interfaces; upgradable to 63 E1 interfaces via
TEX expansion card.
2. The
µ
SDM-1 can be wall mounted, installed in a rack, in an indoor cabinet or
in a street cabinet.
3. Rack mounted equipment must be installed in a rack which complies with
the fire enclosure requirements of EN60950.
4. The recommended distance of the rack from the Optical Fiber Distribution
Frame (ODF) is up to 10 m.
Содержание mSDM-1
Страница 16: ...Introduction SDM 1RD SDM 1 SDM 1E IOM 1 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 26: ...Product Description SDM 1RD SDM 1 SDM 1E IOM 2 10 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 100: ...Acceptance and Commissioning SDM 1RD SDM 1 SDM 1E IOM 7 6 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 109: ...426006 2304 013 B1 Lightscape Networks Ltd Proprietary B 1 Packing List A typical SDM 1 packing list...
Страница 110: ...Packing List SDM 1RD SDM 1 SDM 1E IOM B 2 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 122: ...Connector Pin Outs SDM 1RD SDM 1 SDM 1E IOM C 12 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...
Страница 132: ...Rack Installation Guidelines SDM 1RD SDM 1 SDM 1E IOM E 4 Lightscape Networks Ltd Proprietary 426006 2304 013 B1...