background image

 

 

Moog Inc., Components Group, Halifax Operations  
Focal Technologies Corporation 

77 Frazee Avenue 
Dartmouth, Nova Scotia, Canada B3B 1Z4 
Tel: 902-468-2263 •  Fax: 902-468-2249 
[email protected] •  

www.moogpowerdata.com

 

Application Note

 

 

 

This document is the property of Focal Technologies Corporation, and may not be neither copied, reproduced or otherwise dealt with nor its 
contents communicated to others except in accordance with written instructions received from Focal Technologies Corporation.   

 
700-0290-00 Rev. 1 

Page 1 of 6 

 

  

INITIAL CHECKS 

 

• 

Ensure cards installed and configured as per installation drawing. (Note: in a 16HP medium speed, high density 
system, the FMB is furthest right and the HDB-TX card must be installed in the slot adjacent to the FMB).

 

• 

Ensure correct input power is supplied and verify the primary fuse is not open.

 

• 

Fuses: each module and card have fuse protection.  Ensure there are no input power supply issues or incorrect 
connector wiring before replacing fuses. Several spare kits are available for fuses, e.g. 903-8022-18. 

 

• 

Verify the proper fuse type and value and location per the User's Guide appendices.

 

• 

Ensure voltage rail levels are acceptable using either the diagnostics software or a voltmeter.

 

• 

Ensure external fibers and bushings are clean and have low optical loss. (May be verified with diagnostic 
software or an optical power meter.)

 

• 

Ensure optical output power levels are sufficient at the FMB front panels with an optical power meter:

 

• 

Typically Console FMB 1550nm downlink output power should be -6 dBm or better and Remote FMB 1310nm 
uplink output power should be -6 dBm or better.  Refer to your Model 903 User's Guide for more details on 
output power specifications. 

• 

Ensure receiver power at the FMB front panel is acceptable, typically between -8 dBm and -26 dBm.  Excessive 
receive power will cause errors or possibly even damage the receiver and low receive power will cause errors or 
link faults.  In general, bench testing should be conducted with a 5-10 dB optical attenuator. 

 

 
 

REVIEW SETTINGS 

 

• 

Cards should be shipped from Focal in the default configuration for the specific system. Shunt terminals are 2-
pin or 3-pin; pin 1 is typically designated with a square pad or silk-screened ‘1’.

 

• 

DIP switches are set either on (1) or off (0).  Circuit 1 is the leftmost switch when reading the text on the switch. 

• 

Mode settings should generally match on remote and console cards, except AIB-MS900, AIB-ARCNET, and 
AIB-HYDRO. 

• 

FMB DIP switch settings should not normally be changed.  When troubleshooting an older card with a DIP 
switch, switch the DIP switch back and forth a few times to ensure there is a good, stable contact. 

 
 

USING DIAGNOSTIC SOFTWARE

 

• 

Check for acceptable voltage levels (screen LEDs).

 

• 

Check acceptable temperature, remote and console  (both should be less than +70C). 

• 

Check for uplink/downlink errors (<= 1 error per hour typical). 

• 

Verify expected optical levels (transmitted and received) with fiber optic power meter. 

• 

Verify flux budget with VOAT (Variable Optical Attenuator), per user's guide. 

• 

Observe strip chart for unusual power fluctuations in the optical link. 

• 

Verify losses of video sync. 

• 

Log diagnostics files for long term monitoring. 

• 

When new FMBs are installed, the software may need to be recalibrated for optical readings. (OK if within 2 dB). 

 
 

MODEL 903 EVALUATING AND TROUBLE-SHOOTING GUIDE

 

 
Doc. No. 

 
700-0290-00 

 
Revision: 

 

 
Date: 

 
2006 March 01 

 
 

 
 

Содержание 903

Страница 1: ...should be 6 dBm or better Refer to your Model 903 User s Guide for more details on output power specifications Ensure receiver power at the FMB front panel is acceptable typically between 8 dBm and 26 dBm Excessive receive power will cause errors or possibly even damage the receiver and low receive power will cause errors or link faults In general bench testing should be conducted with a 5 10 dB o...

Страница 2: ...RS 422 Cross over Pins 1 2 Mux Rx and 3 4 Mux Tx are the same at both ends Hence RS 422 coming into the mux on pins 1 2 at one end will exit the mux at the other end on pins 3 4 for the corresponding channel MS900 AIB settings Jumper on AIB must be set one way for the remote and the opposite way for the console ARCNET AIB settings Mux and sonar settings must match per manual MOST COMMON OPTICAL PR...

Страница 3: ...oard not connected at the remote end 903 HD only Install ribbon cable at J5 of both HDB TX and DATA IO boards No data and or no data LEDs Non working data daughtercard Replace daughtercard No Video Improper channel configuration see also no link lights Reference appropriate manual section for video and high density board configuration No video sync lights at console No video source at remote end P...

Страница 4: ...reen LED T ON data being transmitted out of card front panel Red LED R ON data being received into card front panel Non digital i o cards e g AIB MS900 or blank sockets force both LEDs on Remote Module Data I O 903 HD Only Two LEDs for each channel indicate the presence of a signal transmitted or received Green LED T ON data being transmitted out of i o box Red LED R ON data being received into i ...

Страница 5: ...GUIDELINES Use ESD protection as appropriate Ensure unit is powered down when removing or installing cards as the system is not hot swappable Unscrew both captured front panel screws but leave a few threads on upper screw to prevent popping out Pull on card until backplane connector unmates Undo the upper screw completely and withdraw the card slowly especially if it is an optical card or adjacent...

Страница 6: ...tallation or well after successful installation i e did the problem occur with no changes to a previously working system Log a diagnostics file if relevant and email it to Focal Diagnositcs files include all optical measurements temperature voltage levels video syncs and errors detected Ensure the log file is configured properly per the software users manual The various log fields may be enabled d...