Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
47
8400 motec | Software Manual
Device control (DCTRL)
Device state machine and device states
4.2.6
OperationEnabled
In the "OperationEnabled" state
is the controller if the controller inhibit is deactivated and no trouble ("Trouble") and
fault ("Fault") are existent.
the operation is enabled and the motor follows the setpoint defined by the active
application (with sensorless vector control only after magnetisation has been
completed).
Depending on certain conditions, a state change takes place based on the
"OperationEnabled" device state.
Related topics:
LED DRIVE READY
LED DRIVE ERROR
Display in
Display in status word 1 (
)
Bit 11
Bit 10
Bit 9
Bit 8
Off
OperationEnabled
0
1
0
1
Change condition
Changeover to the device state
Control bit "EnableOperation" in control word
wDriveControl
= "0"
OR
terminal RFR = LOW level (controller inhibit).
Control bit "SwitchOn" = "0".
Undervoltage in the DC bus.
(depending on
)
Error with error response "Trouble" occurs.
Содержание 8400 motec Series
Страница 375: ...L 375 ...