Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
199
8400 motec | Software Manual
Diagnostics & error management
Monitoring
9.5
Monitoring
The controller is provided with various monitoring functions which protect the drive
against impermissible operating conditions.
If a monitoring function responds,
– an entry will be made into the
of the controller,
– the response (Trouble, Fault, etc.) set for this monitoring function will be triggered,
– the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRIVE ERROR" LED on the top of the controller goes
on:
Related topics:
Device state machine and device states
Device overload monitoring (Ixt)
Motor temperature monitoring (PTC)
Brake resistor monitoring (I2xt)
Mains phase failure monitoring
Response
Entry in the
logbook
Display in
Pulse inhibit
Controller
inhibit
Acknowledge
ment
required
LED red
"DRIVE ERROR"
None
Off
Fault
;
;
;
;
;
Trouble
;
;
;
;
(after 0.5 s)
WarningLocked
;
;
;
Содержание 8400 motec Series