Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
271
8400 motec | Software Manual
Parameter reference
Parameter list | C00480
C00480
C00481
C00482
C00495
Parameter | Name:
C00480 | LS_DisFree_b
Data type: UNSIGNED_8
Index: 24095
d
= 5E1F
h
SB
: Display of the input values
Display area
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 bDis1
Signal level input
bDis1
...
bDis8
... ...
Bit 7 bDis8
;
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00481 | LS_DisFree
Data type: UNSIGNED_16
Index: 24094
d
= 5E1E
h
SB
: Display of the input values
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Bit0
... ...
Bit 15 Bit15
Subcodes
Info
C00481/1
Input values
wDis1
...
wDis4
C00481/...
C00481/4
;
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00482 | LS_DisFree_a
Data type: INTEGER_16
Index: 24093
d
= 5E1D
h
SB
: Display of the input values
Display range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Info
C00482/1
Input values
nDis1_a
...
nDis4_a
C00482/...
C00482/4
;
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00495 | Speed encoder selection
Data type: UNSIGNED_8
Index: 24080
d
= 5E10
h
From version 02.00.00
Selection of the feedback system for the actual speed for motor control and display
Selection list
(Lenze setting printed in bold)
Info
0 No encoder
No encoder available for actual speed detection
1 Encoder signal FreqIn12
Speed encoder signal is fed in via the digital inputs DI1
and DI2
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Содержание 8400 motec Series
Страница 375: ...L 375 ...