Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
251
8400 motec | Software Manual
Parameter reference
Parameter list | C00130
C00130
C00131
C00133
C00134
Parameter | Name:
C00130 | Rated power brake resistor
Data type: UNSIGNED_16
Index: 24445
d
= 5F7D
h
Rated power of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Settings for internal brake resistor E84DZEWxxxx
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
65535
15 W
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00131 | Heat capacity brake resistor
Data type: UNSIGNED_16
Index: 24444
d
= 5F7C
h
Thermal capacity of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Settings for internal brake resistor E84DZEWxxxx
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
kWs
6553.5
0.3 kWs
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 10
Parameter | Name:
C00133 | Load brake resistor
Data type: UNSIGNED_16
Index: 24442
d
= 5F7A
h
Display of the utilisation of the connected brake resistor
Display range
(min. value | unit | max. value)
0
%
65535
;
Read access
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00134 | Ramp smoothing, main setpoint
Data type: UNSIGNED_8
Index: 24441
d
= 5F79
h
FB
: Configuration of the ramp smoothing for the main setpoint
Selection list
(Lenze setting printed in bold)
Info
0 Off
Ramp rounding deactivated
1 PT1 behaviour
Ramp rounding with PT1 behaviour
• The corresponding S-ramp time must be set in
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1