8400 motec | Software Manual
Parameter reference
Parameter list | C00090
246
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
C00090
C00091
C00092
C00093
C00094
Parameter | Name:
C00090 | Rated motor voltage
Data type: UNSIGNED_16
Index: 24485
d
= 5FA5
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0
V
1000
400 V
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00091 | Motor cosine phi
Data type: UNSIGNED_8
Index: 24484
d
= 5FA4
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.40
1.00
0.85
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00092 | Motor magnetising inductance
Data type: UNSIGNED_16
Index: 24483
d
= 5FA3
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
mH
6500.0
0.0 mH
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 10
Parameter | Name:
C00093 | Power section identification
Data type: UNSIGNED_16
Index: 24482
d
= 5FA2
h
Display of the identification of the detected power section of the controller
Display range
(min. value | unit | max. value)
0
65535
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00094 | Password
Data type: INTEGER_32
Index: 24481
d
= 5FA1
h
The controller provides the opportunity to prevent the unauthorised access to the menu level of the keypad by
assigning a password.
When the password protection is activated, the correct password must be entered in the keypad to activate the
access to the menu level. If you enter the wrong password, the keypad can only access the parameters of the user
menu.
• Activating the password protection: Set the desired password (1 ...9999) and save parameter set.
• When "0" is set, the password protection is deactivated.
Setting range
(min. value | unit | max. value)
Lenze setting
0
9999
0
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1