Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
259
8400 motec | Software Manual
Parameter reference
Parameter list | C00166
C00166
C00167
C00168
C00169
C00170
Parameter | Name:
C00166 | Error information text
Data type: VISIBLE_STRING
Index: 24409
d
= 5F59
h
Display of details of the currently pending error
Subcodes
Info
C00166/1
Resp. - current error
• Response of the currently pending error
C00166/2
Subj.area curr. error
• Subject area of the currently pending error
C00166/3
Mess.curr.error
• Textual message of the currently pending error
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C00167 | Logbook data
Data type: OCTET_STRING
Index: 24408
d
= 5F58
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00168 | Error number
Data type: UNSIGNED_32
Index: 24407
d
= 5F57
h
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C00168/1
Display of the internal error number for the last 8
occurred errors
C00168/...
C00168/8
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00169 | Time of error
Data type: UNSIGNED_32
Index: 24406
d
= 5F56
h
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C00169/1
Display of the time of error for the last 8 occurred errors
C00169/...
C00169/8
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00170 | Error counter
Data type: UNSIGNED_8
Index: 24405
d
= 5F55
h
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00170/1
Display of the error counter for the last 8 occurred errors
C00170/...
C00170/8
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1