
8400 motec | Software Manual
Function library
L_MPot_1
314
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
12.1
L_MPot_1
This FB replaces a hardware motor potentiometer and can be used as an alternative
setpoint source which is controlled via two inputs.
The signal is output via a ramp function generator with linear ramps.
The acceleration and deceleration times are set via parameters.
Constant ramping even with speed limit values changed online.
The motor potentiometer function can be switched on/off online via parameters or a
process signal.
Inputs
Identifier
Data type
Information/possible settings
bEnable
BOOL
Switch over motor potentiometer function
bEnable
code are ORed.
TRUE Motor potentiometer function is active, setpoint can be changed via
bUp
and
bDown
.
• With switching to TRUE, the value applied to
nIn_a
is
automatically transferred to the motor potentiometer.
FALSE The value applied to
nIn_a
is output at
nOut_a
.
nln_a
INT
When bEnable = FALSE, the analog input signal nIn_ is switched to the nOut_a
output.
bUp
BOOL
Approaching of the upper speed limit value set in
TRUE The
nOut_a
output signal runs to its upper limit value (
nHighLimit
).
• If the
bDown
input is simultaneously set to TRUE, the
nOut_a
output signal is not changed.
bDown
BOOL
Approaching of the lower speed limit value set in
.
TRUE The
nOut_a
output signal runs to its lower limit value (
nLowLimit
).
• If the
bUp
input is simultaneously set to TRUE, the
nOut_a
output
signal is not changed.
bInAct
BOOL
Deactivate motor potentiometer function
• This input has the highest priority.
• When the motor potentiometer is deactivated, the
nOut_a
output signal follows
the function set with code
TRUE Motor potentiometer function is deactivated.
/B03RWB
E(QDEOH
Q2XWBD
Q,QBD
E8S
E,Q$FW
E'RZQ
,QLWLDOL]DWLRQIXQFWLRQ
&
/RZHUOLPLW
&
&
&
8SSHUOLPLW
$FFWLPH
& 'HFWLPH
'HDFWLYDWLRQIXQFWLRQ
&
&
&
&
&
&
&
Содержание 8400 motec Series
Страница 375: ...L 375 ...