Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
283
8400 motec | Software Manual
Parameter reference
Parameter list | C00701
C00701
C00720
Parameter | Name:
C00701 | LA_NCtrl: digital connection list
Data type: UNSIGNED_16
Index: 23874
d
= 5D42
h
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00701/1
0: Not connected
: bCInh
C00701/2
10: DigIn_CInh
: bFailReset
C00701/3
0: Not connected
: bSetQuickstop
C00701/4
13: DigIn_bIn3
: bSetDCBrake
C00701/5
14: DigIn_bIn4
: bSetSpeedCcw
C00701/6
11: DigIn_bIn1
C00701/7
12: DigIn_bIn2
C00701/8
0: Not connected
: bMPOTUp
C00701/9
0: Not connected
: bMPOTDown
C00701/10
0: Not connected
: bMPOTInAct
C00701/11
0: Not connected
: bMPotEnable
C00701/12
0: Not connected
: bRFG_0
C00701/13
0: Not connected
: bSetError1
C00701/14
0: Not connected
: bSetError2
C00701/15
1: C_bTrue
: bPIDInfluenceRamp
C00701/16
0: Not connected
: bPIDIOff
C00701/17
1: C_bTrue
: bRLQCw
C00701/18
0: Not connected
: bRLQCcw
C00701/19
15: DigIn_bIn5
: bBrkRelease
C00701/20
0: Not connected
: bClkUp
C00701/21
0: Not connected
: bClkDown
C00701/22
0: Not connected
: bLoad
C00701/23
0: Not connected
: bIn
C00701/24
0: Not connected
: bIn
C00701/25
0: Not connected
: bExecute
C00701/26
0: Not connected
: bSelectWriteValue_1
C00701/27
0: Not connected
Reserved
C00701/28
0: Not connected
:bIn1
C00701/29
0: Not connected
:bIn2
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00720 | L_DigitalDelay_1 delay
Data type: UNSIGNED_32
Index: 23855
d
= 5D2F
h
Switch-on/off delay time
Setting range
(min. value | unit | max. value)
0.0
s
3600.0
Subcodes
Lenze setting
Info
C00720/1
0.0 s
: On delay
C00720/2
0.0 s
: Off delay
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Содержание 8400 motec Series
Страница 375: ...L 375 ...