Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
295
8400 motec | Software Manual
Parameter reference
Parameter list | C01087
C01087
C01100
C01101
C01206
Parameter | Name:
C01087 | LS_WriteParamList: WriteValue_2
Data type: INTEGER_32
Index: 23488
d
= 5BC0
h
: Parameter values - value set 2
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01087/1
0
Parameter values - value set 2
• Parameter values for the parameters defined in
/1 ... 16.
C01087/...
C01087/16
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01100 | L_Counter_1: Function
Data type: UNSIGNED_8
Index: 23475
d
= 5BB3
h
Selection of reset function
Selection list
0 Normal counting
1 Auto reset
2 Manual reset
Subcodes
Lenze setting
Info
C01100/1
0: Normal counting
: Function
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01101 | L_Counter_1: Comparison
Data type: UNSIGNED_8
Index: 23474
d
= 5BB2
h
Selection of comparison operation
Selection list
0 Greater than or equal to
1 Less than or equal to
2 equal to
Subcodes
Lenze setting
Info
C01101/1
0: Greater than or equal to
: Comparison
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01206 | Axis data: Mounting direction
Data type: UNSIGNED_8
Index: 23369
d
= 5B49
h
From version 02.00.00
Inversion with mirrored mounting of motor and encoder
Selection list
0 Not inverted
1 Inverted
Subcodes
Lenze setting
Info
C01206/1
0: Not inverted
Motor mounting direction
• Setting of the motor mounting rotated 180°.
C01206/2
0: Not inverted
Position encoder mounting direction
• Setting of the mounting of a position encoder system
rotated 180°.
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Содержание 8400 motec Series
Страница 375: ...L 375 ...