Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
39
8400 motec | Software Manual
Device control (DCTRL)
Device commands (C00002/x)
4.1.6
Activate/Deactivate quick stop
The
= "1: On / start" device command activates the quick stop function, i.e. the
motor control is separated from the setpoint selection, and within the deceleration time
parameterised in
the motor is brought to a standstill (n
ist
= 0).
The motor is kept at a standstill during closed-loop operation.
A pulse inhibit (CINH) is set if the auto-DCB function has been activated via
The
= "0: Off / ready" device command deactivates the quick stop again,
provided that no other source of a quick stop is active.
Tip!
displays a bit code of active sources/causes for the quick stop.
4.1.7
Reset error
The
= "1: On / start" device command acknowledges an existing error message
if the error cause has been eliminated and thus the error is not pending anymore.
After resetting the current error, further errors may be pending which must be reset as
well.
The status-determining error is displayed in
The current error is displayed in
Tip!
An error message can also be acknowledged by activating the
Reset error
button in
the
Diagnostics
tab.
In the Lenze setting, switching RFR causes also causes an error acknowledgement
(see configuration parameter
Detailed information on error messages can be found in the chapter entitled
Diagnostics & error management
Parameter
Info
Lenze setting
Value Unit
Deceleration time - quick stop
2.000 s