8400 motec | Software Manual
Drive application
Interface description
154
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
7.2
Interface description
Tip!
You can change the preconfigured assignment of the respective input via the
configuration parameters given in the first column.
User-defined terminal assignment
Inputs
Identifier
Data type
Configuration parameters
Information/possible settings
nMainSetValue_a
INT
Main speed setpoint
• Scaling: 16384
≡
100 % rated speed (
• The main setpoint is transformed to a speed setpoint in the setpoint encoder via
a ramp function generator with linear or S-shaped ramps.
• Upstream to the ramp function generator, a blocking speed masking function
and a setpoint MinMax limitation are effective.
• For a detailed functional description see FB
nTorqueMotLim_a
nTorqueGenLim_a
INT
Torque limitation in motor mode and in generator mode
• These input signals are directly transferred to the motor control to limit the
controller's maximum torque in motor and generator mode.
• The drive cannot output a higher torque in motor/generator mode than set here.
• The applied values (any polarity) are internally interpreted as absolute values.
• If sensorless vector control (SLVC) is selected, the limitation has a direct effect on
the torque-producing current component.
• Scaling: 16384
≡
100 % M
max
(
)
Torque limits in motor and generator mode:
Device control
wDriveControl
WORD
Control word via communication interface
• In the control mode "40: Network (MCI/CAN)", the controller controlled by a
master control (e.g. IPC) receives its control word via the communication
interface (MCI/CAN). The process data word is provided at this input by the
upstream port block
• See the "
" subchapter for a detailed description of the
individual control bits.
n
N
M
N
M
-M
N
-n
N
n
TorqueMotLim
TorqueGenLim
TorqueMotLim
TorqueMotLim
TorqueGenLim