C00820
C00821
C00830
Parameter | Name:
C00820 | L_DigitalLogic_1: Function
Data type: UNSIGNED_8
Index: 23755
d
= 5CCB
h
From version 02.00.00
FB
: Selection of the internal logic interconnection
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND bIn2
AND operation
3 bOut = bIn1 OR bIn2
OR operation
4 bOut = f(truth table)
The truth table parameterised in
is used.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00821 | L_DigitalLogic_1: Truth table
Data type: UNSIGNED_8
Index: 23754
d
= 5CCA
h
From version 02.00.00
FB
: Parameter setting of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00821/1
0: FALSE
bIn1=0/bIn2=0
C00821/2
0: FALSE
bIn1=1/bIn2=0
C00821/3
0: FALSE
bIn1=0/bIn2=1
C00821/4
0: FALSE
bIn1=1/bIn2=1
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00830 | 16-bit analogue input
Data type: INTEGER_16
Index: 23745
d
= 5CC1
h
Display in percent of 16-bit input values of different blocks
Display range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Info
C00830/1
: nNSet_a
C00830/2
: nOut_a
C00830/3
LS_MCTRL: nSpeedSetValue_a
C00830/4
LS_MCTRL: nTorqueMotLimit_a
C00830/5
LS_MCTRL: nTorqueGenLimit_a
C00830/6
: nAct_a
C00830/7
: nAdapt_a
C00830/8
: nSet_a
C00830/9
: nInflu_a
C00830/10
: nNSet_a
C00830/11
: nIn_a
C00830/12
Reserved
C00830/13
: nIn1_a
C00830/14
: nIn2_a
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100