Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
157
8400 motec | Software Manual
Drive application
Interface description
Process controller
• In the Lenze setting, the process controller is deactivated.
• The activation is executed by selecting the operating mode in
• For a detailed functional description see FB
.
bPIDEnableInfluenceRamp
BOOL
Activate ramp for influencing factor
FALSE Influencing factor of the PID controller is ramped down to "0".
TRUE Influencing factor of the PID controller is ramped up to the value
nPIDInfluence_a
.
bPIDOff
BOOL
Switch off I-component of process controller
• In conjunction with the operating mode set in
(Lenze setting: "Off").
TRUE I-component of the process controller is switched off.
nPIDVpAdapt_a
INT
Adaptation of gain Vp set in
in percent
• Scaling: 16384
≡
100 %
• Internal limitation to ± 199.99 %
• Changes can be done online.
nPIDActValue_a
INT
Speed or actual sensor value (actual process value)
• Scaling: 16384
≡
100 %
• Internal limitation to ± 199.99 %
nPIDInfluence_a
INT
Limitation of the influencing factor in percent
• The influence factor of the PID controller can be limited to a certain value (-
199.99% ... + 199.99%) via
nPIDInfluence_a
.
• Scaling: 16384
≡
100 %
• Internal limitation to ± 199.99 %
nPIDSetValue_a
INT
Sensor setpoint or process setpoint for operating mode 2
• Scaling: 16384
≡
100 %
• Internal limitation to ± 199.99 %
Holding brake control
• In the Lenze setting, the holding brake control is deactivated.
• The activation is executed by selecting the operating mode in
• For a detailed function description see chapter entitled "
".
bBrkRelease
BOOL
Manual release of the brake in connection with the selected operating mode.
• In the Lenze setting, this input is connected to the digital input DI5.
FALSE Do not release the brake manually.
TRUE Release brake manually (forced release).
•
Note!
The brake can also be released if the controller is inhibited!
• During automatic operation, the internal brake logic is
deactivated and the brake is released (supervisor operation). If a
controller inhibit has been set by the brake control, it will be
deactivated.
• In semi-automatic operation, the brake is released after
feedforward control.
nBrkTorqueAdd_a
INT
In preparation - without function at the moment!
Additive torque value in [%] for torque precontrol on starting
• Only effective with sensorless vector control.
• 100 %
≡
maximum torque (
)
Feedforward control of the motor before release
Identifier
Data type
Configuration parameters
Information/possible settings