Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
261
8400 motec | Software Manual
Parameter reference
Parameter list | C00177
C00177
C00178
C00179
C00182
C00200
C00201
Parameter | Name:
C00177 | Switching cycles
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
Counter of different switching cycles and stressful situations
Display range
(min. value | unit | max. value)
0
2147483647
Subcodes
Info
C00177/1
Number of mains switching cycles
C00177/2
Number of switching cycles of the output relay
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00178 | Elapsed-hour meter
Data type: UNSIGNED_32
Index: 24397
d
= 5F4D
h
Display of the operating hours in "seconds" unit
Display range
(min. value | unit | max. value)
0
s
2147483647
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00179 | Power-on time meter
Data type: UNSIGNED_32
Index: 24396
d
= 5F4C
h
Display of the power-on time in "seconds" unit
Display range
(min. value | unit | max. value)
0
s
2147483647
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00182 | S-ramp time PT1
Data type: INTEGER_16
Index: 24393
d
= 5F49
h
FB
: PT1 S-ramp time for the main setpoint ramp function generator
• Only effective with activated ramp smoothing (
= "1").
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
s
50.00
20.00 s
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Display of the firmware product type
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C00201 | Firmware compile date
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Display of the firmware compilation date
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Содержание 8400 motec Series
Страница 375: ...L 375 ...