8400 motec | Software Manual
Commissioning
Commissioning with the »Engineer«
28
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
4. Adapt parameters of the application:
Tip!
• Via the
Signal flow
button, you get one dialog level lower to the signal flow of
the application with further parameterisation opportunities. See chapter
• The preconfigured I/O connection in the selected control mode can be changed
via configuration parameters. See chapter entitled "
More detailed informaton on the technology application:
Setting parameters (short overview)
Parameter
Lenze setting
Info
Value Unit
Accel. time - main setpoint
(
2.0 s
The setpoint is led via a ramp function generator with
linear characteristic. The ramp function generator
converts setpoint step-changes at the input into a ramp.
Decel. time - main setpoint
(
)
2.0 s
Reference speed
(
)
1500 rpm
All speed setpoint selections are provided in % and
always refer to the reference speed set in
The motor reference speed is given on the motor
nameplate.
Deceleration time - quick
stop
(
)
5.0 s
When "quick stop" is requested, the motor control is
decoupled from the setpoint selection and, within the
deceleration time parameterised in
, the motor
is brought to a standstill (n
act
= 0).
Activate/Deactivate quick stop (
Fixed setpoint 1
(
)
40.0 %
A fixed setpoint for the setpoint generator can be
activated instead of the main setpoint via the selection
inputs
bJogSpeed1
and
bJogSpeed2
.
• The fixed setpoints are selected in [%] based on the
reference speed (
Fixed setpoint 2
(
)
60.0 %
Fixed setpoint 3
(
)
80.0 %