Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
243
8400 motec | Software Manual
Parameter reference
Parameter list | C00054
C00054
C00056
C00057
C00058
C00059
C00061
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_16
Index: 24521
d
= 5FC9
h
Display of the current motor current/output current of the inverter
Display range
(min. value | unit | max. value)
0.00
A
300.00
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00056 | Torque
Data type: INTEGER_32
Index: 24519
d
= 5FC7
h
Display of the current torque
Display range
(min. value | unit | max. value)
-99.00
Nm
99.00
Subcodes
Info
C00056/1
Torque setpoint
• Only with sensorless vector control (
).
C00056/2
Actual torque
• Estimated actual torque for all motor control modes.
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00057 | Maximum torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display of the maximum torque to be generated by the motor
• The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode
) and the motor type used.
Display range
(min. value | unit | max. value)
0.0
Nm
999.9
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00058 | Output frequency
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Display of the current output frequency
Display range
(min. value | unit | max. value)
-655.0
Hz
655.0
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in
.
Display range
(min. value | unit | max. value)
0.0
Hz
999.9
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range
(min. value | unit | max. value)
-50
°C
150
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1