Device overload monitoring (Ixt)
displays the device utilisation (ixt) in [%] in different time intervals:
If the device utilisation reaches the warning threshold set in
(Lenze setting:
100 %):
– The error response set in
will be carried out (Lenze setting: "Warning").
– The "
" error message will be entered into the logbook.
= "0: No Reaction" deactivates the monitoring.
If the device utilisation reaches the permanent shutdown limit 110 %:
– The error response "Fault" will be carried out.
– The "
OC9: Ixt overload shutdown limit
" error message will be entered into the
logbook.
Parameter
Info
Device utilisation (Ixt)
• Maximum value of pulse utilisation (
and permanent utilisation (
Device utilisation (Ixt) 15s
• Pulse utilisation over the last 15 seconds (only for loads >160 %).
Device utilisation (Ixt) 3 min
• Permanent utilisation over the last 3 minutes.
Highlighted in grey = display parameter