Device control (DCTRL)
Device state machine and device states
48
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
4.2.7
Trouble
In the "Trouble" device state
is the controller if monitoring has caused a "Trouble" error response.
the motor has no torque (is coasting) due to the inhibit of the inverter.
Depending on certain conditions a state change takes place based on the "Trouble" device
state.
Related topics:
Basics on error handling in the controller
Error messages of the operating system
LED DRIVE READY
LED DRIVE ERROR
Display in
Display in status word 1 (
)
Bit 11
Bit 10
Bit 9
Bit 8
Off
Trouble
0
1
1
1
Note!
The "Trouble" device state is automatically abandoned if the error cause has
been removed.
If in
the
"Inhibit at trouble" auto-start option has been activated, an
explicit deactivation of the controller inhibit is required for leaving the state.
Change condition
Changeover to the device state
The error cause is no longer active.
Control bit "EnableOperation" in control word
wDriveControl
= "1"
AND
terminal RFR = HIGH level (controller enable)
AND
the message has been cancelled.
Control bit "EnableOperation" in control word
wDriveControl
= "0"
OR
terminal RFR = LOW level (controller inhibit)
AND
the message has been cancelled.