3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. (Trained Service technician only) Replace the system board.
5. (Trained Service technician only) Replace the processor.
•
S.3020007 A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
2.
Update the UEFI image.
3. (Trained service technician only) Replace the system board.
•
S.3028002 Boot permission timeout detected. Boot Permission Negotiation Timeout
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check CMM/IMM logs for communication errors and resolve.
2.
Reseat the system
3. If problem persists contact support
•
S.3030007 A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2.
Update the UEFI image.
3.
Replace the system board.
1026
System x3500 M5 Installation and Service Guide
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......