1. Check the Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
2. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move
affected Processor to another Processor socket and retry. If problem follows the affected
Processor, or this is a single Processor system, replace the Processor.
3. (Trained Service technician only) Inspect Processor socket on each Processor removal and
replace system board first if damaged or mis-aligned pins are found. Replace the system board.
•
S.2011001 An Uncorrected PCIe Error has Occurred at Bus [arg1] Device [arg2] Function [arg3].
The Vendor ID for the device is [arg4] and the Device ID is [arg5]. PCI SERR Detected
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ToolsCenter Suite CLI Utility.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. (Trained Service technician only) Replace the system board.
5. (Trained Service technician only) Replace the processor.
•
S.2018001 An Uncorrected PCIe Error has Occurred at Bus [arg1] Device [arg2] Function [arg3].
The Vendor ID for the device is [arg4] and the Device ID is [arg5]. PCIe Uncorrected Error Detected
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ToolsCenter Suite CLI Utility.
Appendix B. UEFI (POST) error codes
1025
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......