Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4.
Reseat the fans.
5. Replace the fans. (n = fan number)
•
800b050c-2581xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050c2581xxxx or 0x800b050c2581xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix:
PLAT
ID:
0810
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
420
System x3500 M5 Installation and Service Guide
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......