Step 6.
Install the server in the rack cabinet (see the
Tower to Rack Installation Instructions
that come with
the server for instructions).
Step 7.
Slide the server back into the rack, if necessary.
Step 8.
Start the server. Confirm that it starts correctly and recognizes the newly installed devices, and
make sure that no error LEDs are lit.
Step 9.
( Business Partners only) Complete the additional steps in “Instructions for Business Partners”
on page 23.
Replacing the fan cage assembly
Use this information to replace the fan cage assembly.
Attention:
Make sure that all wires and cables inside the server are routed correctly before you install
the fan cage assembly. Wiring that is not properly routed might be damaged or might prevent the fan
cage assembly from seating properly in the server.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
To replace the fan cage assembly, complete the following steps.
Step 1.
Align the guides on the fan cage with the release latch to the open position on each side.
Step 2.
Push the fan cage assembly into the server.
Note:
Make sure that the fan cage is fully seated.
Step 3.
Rotate the fan cage release latch to the close position. The fan cage will be fully seated when it
is secured.
00
00
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
00
0
0
00
00
00
00
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
0000000000000
1
2
Fan cage assembly
Figure 89. Rotate the fan cage release latch
Step 4.
Connect the fan cage assembly power cable to the system board (see “Internal cable routing and
connectors” on page 33).
98
System x3500 M5 Installation and Service Guide
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......