Explanation:
Severity
Error
User Response
Complete the following steps:
1. If a DIMM connector error LED is lit, resolve the failure.
2. Make sure that the DIMM connectors are correctly populated for mirroring mode.
•
W.580A2 Invalid memory configuration for Sparing Mode. Please correct memory configuration.
Unsupported DIMM Population for Spare Mode
Explanation:
Severity
Error
User Response
Complete the following steps:
1. If a DIMM connector error LED is lit, resolve the failure.
2. Make sure that the DIMM connectors are correctly populated for sparing mode, according to
the service information for this product.
•
W.68002 A CMOS battery error has been detected CMOS Battery Fault
Explanation:
Severity
Error
User Response
Complete the following steps:
1. If the system was recently installed, moved, or serviced, make sure the battery is properly
seated.
2. Check the Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
3.
Replace the CMOS battery.
4. (Trained technician only)Replace the system board
Appendix B. UEFI (POST) error codes
1039
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......