Attention:
To maintain proper system cooling, do not operate the server for more than 10 minutes without
either a drive or a filler panel installed in each drive bay.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove a 3.5-inch simple-swap hard disk drive, complete the following steps.
Step 1.
Turn off the server and peripheral devices and disconnect all power cords.
Step 2.
Unlock the left-side cover.
Note:
You must unlock the left-side cover to open or remove the bezel. When you lock the left-side
cover, it locks both the cover and the bezel.
Step 3.
Open the bezel (see “Removing the bezel” on page 184).
Step 4.
Press the release latch to open the drive handle. Then, to grasp the drive handle and pull the
hard disk drive out of the drive bay.
0
000
00
000
00
00
0
000000000
0
0
Handle
Latch
3.5-inch simple-swap
hard disk drive
3.5-inch filler panel
Figure 124. Simple-swap hard disk drive removal
If you are instructed to return the server component or optional device, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing a 3.5-inch simple-swap hard disk drive
Use this information to install a 3.5-inch simple-swap hard disk drive.
Before installing a 3.5-inch simple-swap hard disk drive, read the following information:
• Inspect the drive tray for signs of damage.
Removing and replacing components
205
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......