background image

816f050d-0422xxxx : Critical Array [ComputerSystemElementName] has deasserted. (SDRAID

Drive 3)

This message is for the use case when an implementation has detected that an Critical Array has
deasserted.

May also be shown as 816f050d0422xxxx or 0x816f050d0422xxxx

Severity

Info

Serviceable

No

Automatically notify support

No

Alert Category

Critical - Hard Disk drive

SNMP Trap ID

5

CIM Information

Prefix:

PLAT

ID:

0175

User Response

No action; information only.

816f050d-0423xxxx : Critical Array [ComputerSystemElementName] has deasserted. (SDRAID

Drive 4)

This message is for the use case when an implementation has detected that an Critical Array has
deasserted.

May also be shown as 816f050d0423xxxx or 0x816f050d0423xxxx

Severity

Info

Serviceable

No

Automatically notify support

No

Alert Category

Critical - Hard Disk drive

SNMP Trap ID

5

CIM Information

Prefix:

PLAT

ID:

0175

User Response

No action; information only.

Appendix A. Integrated Management Module II (IMM2) error messages

919

Содержание System x3500 M5 Type 5464

Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...

Страница 2: ...ty information warranties and licenses information on the Lenovo Web site at https support lenovo com documents LNVO DOCS Eleventh Edition May 2017 Copyright Lenovo 2015 2017 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Страница 3: ...ing a DVD drive 54 Installing an optional tape drive 58 Hard disk drive installation 61 Installing a 2 5 inch hot swap hard disk drive 68 Installing a 3 5 inch hot swap hard disk drive 70 Installing a 3 5 inch simple swap hard disk drive 72 Memory module installation 73 DIMM installation sequence 76 Memory mirrored channel 76 Memory rank sparing 78 Installing a DIMM 79 Installing an adapter 81 Ins...

Страница 4: ...roblem determination tips 159 Recovering the server firmware UEFI update failure 160 In band manual recovery method 160 In band automated boot recovery method 161 Out of band method 161 Automated boot recovery ABR 161 Nx boot failure 162 Chapter 5 Parts listing Lenovo System x3500 M5 Type 5464 163 Replaceable server components 163 Structural parts 174 Power cords 176 Chapter 6 Removing and replaci...

Страница 5: ...documentation 1200 Getting help and information from the World Wide Web 1200 How to send DSA data 1200 Creating a personalized support web page 1200 Software service and support 1201 Hardware service and support 1201 Taiwan product service 1201 Appendix E Notices 1203 Trademarks 1204 Important notes 1204 Recycling information 1204 Particulate contamination 1205 Telecommunication regulatory stateme...

Страница 6: ...iv System x3500 M5 Installation and Service Guide ...

Страница 7: ...en Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet Antes de instalar este produto le...

Страница 8: ...t determine how serious the hazard is and whether you must correct the problem before you work on the product Consider the following conditions and the safety hazards that they present Electrical hazards especially primary power Primary voltage on the frame can cause serious or fatal electrical shock Explosive hazards such as a damaged CRT face or a bulging capacitor Mechanical hazards such as loo...

Страница 9: ...wer off EPO switch disconnecting switch or electrical outlet so that you can turn off the power quickly in the event of an electrical accident Disconnect all power before you perform a mechanical inspection work near power supplies or remove or install main units Before you work on the equipment disconnect the power cord If you cannot disconnect the power cord have the customer power off the wall ...

Страница 10: ...ny cables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded electrical outlet Connect to properly wired outlets any equipment that will be attached to this product When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire w...

Страница 11: ...h as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure...

Страница 12: ...evice The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 Statement 6 CAUTION If you install a strain relief bracket option over the end of the power cord that is connected to the device you must connect the other end of the power cord to an easily accessible power source Stateme...

Страница 13: ...blem with one of these parts contact a service technician DO NOT open up the chassis or any other parts of any UPS unit This will void the unit warranty Only replace parts for which a serviceable part exists that is servicing any UPS unit is limited to FRU CRU replacement parts Statement 11 CAUTION The following label indicates sharp edges corners or joints nearby Statement 12 CAUTION The followin...

Страница 14: ...e information that is provided with your device for electrical specifications Statement 15 CAUTION Make sure that the rack is secured properly to avoid tipping when the server unit is extended Statement 17 CAUTION The following label indicates moving parts nearby Statement 26 CAUTION Do not place any object on top of rack mounted devices Statement 27 CAUTION Hazardous moving parts are nearby xii S...

Страница 15: ...e battery as instructed by local regulations In the United States Lenovo has a process for the collection of this battery For information call 1 800 426 4333 Have the Lenovo part number for the battery unit available when you call DO NOT mix old and new batteries in an Uninterruptible Power Supply unit DO NOT open up any battery pack retrieved from an Uninterruptible Power Supply unit Wear safety ...

Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...

Страница 17: ...chnologies which help increase performance and reliability For more information see What your server offers on page 9 and Reliability availability and serviceability on page 13 You can obtain up to date information about the server and other Lenovo server products at http shop lenovo com us en systems At http www lenovo com support you can create a personalized support page by identifying Lenovo p...

Страница 18: ...might differ slightly from your hardware 000 000 000 000 Model type serial number Figure 1 ID label on the front of the server The MAC address label is on the top side of the user information tag Note The illustrations in this document might differ slightly from your hardware Figure 2 MAC address label You can download the Lenovo ServerGuide Setup and Installation CD to help you configure the hard...

Страница 19: ...documentation These updates are available from the Lenovo website To check for updates go to http www lenovo com support Notices and statements in this document The caution and danger statements in this document are also in the multilingual Safety Information document which is available at https support lenovo com documents LNVO DOCS Each statement is numbered for reference to the corresponding st...

Страница 20: ...the model 4 GB 8 GB and 16 GB registered DIMMs 32 GB and 64 GB load reduction DIMM Drives SATA DVD ROM Multi burner Note Maximum of two devices can be installed Supported hard disk drives Serial Attached SCSI SAS Serial ATA SATA Note External SAS support depends on SPP Card Expansion bays depending on the model Up to thirty two 2 5 inch HDD bays Up to twelve 3 5 inch HDD bays Attention As a genera...

Страница 21: ...s 2 LRDIMM not supported 900 watt ac 1 No limitation Two microprocessors installed 550 watt ac 1 Support up to 90 watt processor 2 Support up to eight 2 5 inch HDDs 3 LRDIMM not supported 4 GPU not supported 750 watt ac 1 Support up to sixteen 2 5 inch HDDs 2 LRDIMM not supported 3 GPU not supported 900 watt ac No GPU installed 1 Support up to sixteen 2 5 inch HDDs 2 Support up to eight LRDIMM 3 G...

Страница 22: ...urator MUST be used Table 3 Power Supply Information for 900W Power Supply 900W 900W 900W 900W 900W CPU Q ty 1 1 2 2 2 CPU Limit max W per CPU 145W 145W 145W 120W 90W DIMM Q ty R 12 12 24 12 12 DIMM Q ty LR 12 12 24 12 0 Max 3 5 HDD Q ty 12 12 12 12 6 Max 2 5 HDD Q ty 32 32 32 16 8 3 5 and 2 5 Intermix 6 16 6 16 6 16 6 8 0 PCIe Q ty GPU incl 4 2 1 GPU 7 4 1 GPU 2 2 GPU GPU Q ty 0 1 0 1 2 Remark Po...

Страница 23: ...ystems management network This system management connector is dedicated to the IMM2 1 functions Light path diagnostics Six Universal Serial Bus ports on the front of server Two USB 2 0 on front of server Two USB 2 0 on rear of server Two USB 3 0 on rear of server One internal USB port for optional USB flash device with embedded hypervisor One internal USB tape connector Video controller integrated...

Страница 24: ...ltitude 3 050 m 10 000 ft 5 C to 33 C 41 F to 91 4 F Maximum rate of temperature change Tape drives 5 C hr 41 F hr Hard disk drives 20 C hr 68 F hr Server off Temperature 5 C to 45 C 41 F to 113 F Relative humidity 8 to 85 Maximum dew point 27 C 80 6 F Storage non operating Temperature 1 C to 60 C 33 8 F to 140 F Altitude 3 050 m 10 000 ft Relative humidity 5 to 80 Maximum dew point 29 C 84 2 F Sh...

Страница 25: ... optional features installed and the power management optional features in use 2 The noise emission level stated is the declared upper limit sound power level in bels for a random sample of machines All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296 Actual sound pressure levels in a given location might exceed the average values stated because of room r...

Страница 26: ...e Setup and Installation CD which you can download from the web provides programs to help you set up the server and install a Windows operating system The ServerGuide program detects installed optional hardware devices and provides the correct configuration programs and device drivers For more information about the ServerGuide Setup and Installation CD see Using the ServerGuide Setup and Installat...

Страница 27: ...odel CIM Web browser For additional information see Using the Integrated Management Module II IMM2 on page 112 and the Integrated Management Module II User s Guide at http publib boulder ibm com infocenter systemx documentation topic com lenovo sysx imm2 doc printable_doc html Integrated network support The server comes with an integrated dual port Intel Gigabit Ethernet controller which supports ...

Страница 28: ... core processors The server supports up to two Intel Xeon E5 2600 series multi core microprocessors The server comes with only one microprocessor installed PCI adapter capabilities The server has seven PCI interface slots See Installing an adapter on page 216 for detailed information Redundant connection The addition of the optional Ethernet daughter card provides failover capability to a redundan...

Страница 29: ... by physically separating the management network traffic from the production network You can use the Setup utility to configure the server to use a dedicated systems management network or a shared network UEFI compliant server firmware The UEFI firmware offers several features including Unified Extensible Firmware Interface UEFI version 2 1 compliance Active Energy Management AEM technology enhanc...

Страница 30: ...lly maps out the memory with the uncorrectable error and the server restarts with the remaining installed memory Menu driven setup system configuration and redundant array of independent disks RAID configuration programs Microprocessor built in self test BIST internal error signal monitoring internal thermal trip signal monitoring configuration checking and microprocessor and voltage regulator mod...

Страница 31: ...ks include discovery inventory configuration system health monitoring updates event notification automation for managed systems hardware log power and light path The Systems Director web and command line interfaces provide a consistent interface that is focused on driving these common tasks and capabilities Discovering navigating and visualizing systems on the network with the detailed inventory a...

Страница 32: ...stalled in the server when this LED is flashing slowly one flash per second it indicates that the drive is being rebuilt When the LED is flashing rapidly three flashes per second it indicates that the controller is identifying the drive DVD drive activity LED When this LED is lit it indicates that the DVD drive is in use DVD eject button Press this button to release a DVD or CD from the DVD drive ...

Страница 33: ...ivity LEDs When any of these LEDs is flashing they indicate that the server is transmitting to or receiving signals from the Ethernet LAN that is connected to the Ethernet port that corresponds to that LED System locator LED Use this blue LED to visually locate the server among other servers You can use Systems Director to light this LED remotely This LED is controlled by the IMM2 1 When you light...

Страница 34: ...on about the error 3 Save the log if necessary and clear the log afterwards Light path diagnostics panel The following illustration shows the front LEDs on the light path diagnostics panel The light path diagnostic panel can be seen from the front bezel Note The light path diagnostics LEDs remain lit only while the server is connected to power For more information about the LEDs on the light path ...

Страница 35: ...ss adapter into this slot PCI slot 5 Insert a half length full height PCI Express adapter into this slot PCI slot 6 Insert a full length full height PCI Express adapter into this slot PCI slot 7 Insert a full length full height PCI Express adapter into this slot Power connector Connect the power cord to this connector Note Power supply 1 is the default primary power supply If power supply 1 fails ...

Страница 36: ...er Green Figure 7 The LEDs on the rear of the server Ethernet activity LEDs When these LEDs are lit they indicate that the server is transmitting to or receiving signals from the Ethernet LAN that is connected to the Ethernet port Ethernet link LEDs When these LEDs are lit they indicate that there is an active link connection on the Ethernet port AC power LED Each hot swap power supply has an ac p...

Страница 37: ... LAN feature can turn on the server What to do next 1 When 4 GB or more of memory physical or logical is installed some memory is reserved for various system resources and is unavailable to the operating system The amount of memory that is reserved for system resources depends on the operating system the configuration of the server and the configured PCI options 2 When you turn on the server with ...

Страница 38: ... system and turn off the server if your operating system supports this feature If the operating system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the server The server can be turned off by Wake on LAN feature with the following limitation Note When you install any PCI adapter the power cords must be disconnected from the power source befor...

Страница 39: ...installed or that a 19990305 error code is displayed indicating that an operating system was not found but the server is otherwise working correctly If the server is not working correctly see Running DSA Preboot diagnostic programs on page 143 for information about how to run diagnostics Step 4 Follow the installation procedures in this chapter and use the correct tools Incorrectly installed devic...

Страница 40: ...send diagnostic data to Lenovo Standard upload http www ibm com de support ecurep send_http html Standard upload with the system serial number http www ecurep ibm com app upload_hw Secure upload http www ibm com de support ecurep send_http html secure Secure upload with the system serial number https www ecurep ibm com app upload_hw Server components The following illustration shows the major comp...

Страница 41: ...C filler 2 5 inch HDD EMC filler 2 5 inch HDD partition cage 3 5 inch filler panel 3 5 inch simple swap HDD 3 5 inch hot swap HDD 2 5 inch hot swap HDD 2 5 inch filler panel DVD drive Tower bezel 5 25 inch bezel 5 25 inch EMC filler Front USB assembly Operator information panel assembly Light path diagnostics assembly Figure 8 Server components System board internal connectors The following illust...

Страница 42: ... 2 DIMM 13 18 connectors DIMM 19 24 connectors SD adapter connector PCI slot 7 PCI slot 6 PCI slot 5 DIMM 7 12 connectors NMI button PCI slot 3 Com port card connector PCI slot 4 DIMM 1 6 connectors Fan power connector PCI slot 2 PCI slot 1 Figure 9 Internal connectors on system board System board external connectors The following illustration shows the external connectors on the system board USB ...

Страница 43: ...itch name Default position Description 1 UEFI boot recovery Off When this switch is off the primary firmware ROM page is loaded When this switch is on the secondary backup firmware ROM page is loaded Note Changing the position of the UEFI boot back switch before the server is turned on alters which flash ROM page is loaded Do not move the switch after the server is turned on This can cause an unpr...

Страница 44: ...page 21 2 Any system board switch or jumper block that is not shown in the illustrations in this document are reserved System board LEDs and controls The following illustration shows the light emitting diodes LEDs on the system board Any error LED can be lit after ac power has been removed from the system board tray so that you can isolate a problem After ac power has been removed from the system ...

Страница 45: ...evice Before you install optional devices read the following information Read the safety information in Safety on page v and the guidelines in Working inside the server with the power on on page 31 and Handling static sensitive devices on page 31 This information will help you work safely Make sure that the devices that you are installing are supported For a list of supported optional devices for ...

Страница 46: ...urn off the server before you perform any steps that involve removing or installing adapter cables and you must disconnect the power source from the server before you perform any steps that involve removing or installing a riser card Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Orange on a ...

Страница 47: ...the server do not wear cuff links while you are working inside the server Do not allow your necktie or scarf to hang inside the server Remove jewelry such as bracelets necklaces rings and loose fitting wrist watches Remove items from your shirt pocket such as pens and pencils that could fall into the server as you lean over it Avoid dropping any metallic objects such as paper clips hairpins and sc...

Страница 48: ...dity and increases static electricity Hard disk drive backplane connectors The following illustrations show the connectors on the 2 5 inch and 3 5 inch hard disk drive backplanes and the backplate assembly Status LED yellow Activity LED green Power configuration connector SAS signal connectors Hard disk drive connectors Figure 13 Connectors on the 3 5 inch hot swap hard disk drive backplane Hard d...

Страница 49: ...pander Internal cable routing and connectors The server uses cables to connect SATA attached hot swap SATA hot swap SAS and DVD drive devices to the power supply and to the system board Review the following information before connecting power and signal cables to internal drives The drives that are preinstalled in the server come with power and signal cables attached If you replace any drives reme...

Страница 50: ... the system board and the microprocessor 2 expansion board Operator information panel cable connection The following illustration shows the internal cable routing and connectors from the operator information panel and the light path diagnostics panel to the system board ODD power cable 4pin ODD signal cable 13pin Operation panel cable Lightpath cable Front USB cable Figure 18 Internal cable routin...

Страница 51: ...under the system board in this system 1 For server models with eight 2 5 inch hot swap hard disk drives System board Power paddle card HDD power cable Y cable SAS signal cable SAS signal cable Cable clip Backplane zoom out Figure 19 Server models with eight 2 5 inch hot swap hard disk drives 2 For server models with sixteen 2 5 inch hot swap hard disk drives and one single ServeRAID adapter Chapte...

Страница 52: ...Backplane zoom out SAS signal cable SAS signal cable Figure 20 Server models with sixteen 2 5 inch hot swap hard disk drives and one single ServeRAID adapter 3 For server models with sixteen 2 5 inch hot swap hard disk drives and two ServeRAID adapters 36 System x3500 M5 Installation and Service Guide ...

Страница 53: ...t HDD mini SAS cable HDD mini SAS cable HDD mini SAS cable Figure 21 Server models with sixteen 2 5 inch hot swap hard disk drives and two ServeRAID adapters 4 For server models with twenty four 2 5 inch hot swap hard disk drives and one single ServeRAID adapter Chapter 2 Installing optional devices 37 ...

Страница 54: ...t SAS signal cable SAS signal cable HDD power cable Y cable Figure 22 Server models with twenty four 2 5 inch hot swap hard disk drives and one single ServeRAID adapter 5 For server models with twenty four 2 5 inch hot swap hard disk drives and two ServeRAID adapaters 38 System x3500 M5 Installation and Service Guide ...

Страница 55: ...l cable SAS signal cable HDD power cable Y cable SAS signal cable SAS signal cable Figure 23 Server models with twenty four 2 5 inch hot swap hard disk drives and two ServeRAID adapters 6 For server models with thirty two 2 5 inch hot swap hard disk drives and one single ServeRAID adapter Chapter 2 Installing optional devices 39 ...

Страница 56: ...ble SAS signal cable HDD power cable Y cable SAS signal cable SAS signal cable Figure 24 Server models with thirty two 2 5 inch hot swap hard disk drives and one single ServeRAID adapter 7 For server models with thirty two 2 5 inch hot swap hard disk drives and two ServeRAID adapters 40 System x3500 M5 Installation and Service Guide ...

Страница 57: ...l cable SAS signal cable HDD power cable Y cable SAS signal cable SAS signal cable SAS signal cable SAS signal cable Figure 25 Server models with thirty two 2 5 inch hot swap hard disk drives and two ServeRAID adapters 8 For server models with six 3 5 inch simple swap hard disk drives 6G Chapter 2 Installing optional devices 41 ...

Страница 58: ...ver models with six 3 5 inch simple swap hard disk drives 12G System board Power paddle card HDD power cable SATA signal cable Cable clip Figure 27 Server models with six 3 5 inch simple swap hard disk drives 12G 10 For server models with six 3 5 inch hot swap hard disk drives and one single ServeRAID adapter 42 System x3500 M5 Installation and Service Guide ...

Страница 59: ...ignal cable Cable clip Backplane zoom out Figure 28 Server models with six 3 5 inch hot swap hard disk drives and one single ServeRAID adapter 11 For server models with twelve 3 5 inch hot swap hard disk drives and two ServeRAID adapters Chapter 2 Installing optional devices 43 ...

Страница 60: ...nal cable SAS signal cable Figure 29 Server models with twelve 3 5 inch hot swap hard disk drives and two ServeRAID adapters 12 For server models with six 3 5 inch hot swap hard disk drives at bottom and eight 2 5 inch hot swap hard disk drives on top and two ServeRAID adapters 44 System x3500 M5 Installation and Service Guide ...

Страница 61: ...in system board power cable Figure 30 Server models with six 3 5 inch hot swap hard disk drives at bottom and eight 2 5 inch hot swap hard disk drives on top and two ServeRAID adapters 13 For server models with six 3 5 inch hot swap hard disk drives at bottom and sixteen 2 5 inch hot swap hard disk drives on top and two ServeRAID adapters Chapter 2 Installing optional devices 45 ...

Страница 62: ...al cable SAS signal cable Figure 31 Server models with six 3 5 inch hot swap hard disk drives at bottom and sixteen 2 5 inch hot swap hard disk drives on top and two ServeRAID adapters 14 Server models with sixteen 2 5 inch hot swap hard disk drives at bottom and six 3 5 inch hot swap hard disk drives on top and two ServeRAID adapters 46 System x3500 M5 Installation and Service Guide ...

Страница 63: ...the bezel Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To open the bezel door follow the steps below Step 1 Unlock the left side cover Note You must unlock the left side cover to open or remove ...

Страница 64: ...tep 3 Open the bezel door by pressing the button on the left edge of the bezel door and rotate the left side of the bezel door away from the server 00 00 00 Release button Figure 34 Open the bezel door 48 System x3500 M5 Installation and Service Guide ...

Страница 65: ...layed indicating that an operating system was not found but the server is otherwise working correctly If the server is not working correctly see Running DSA Preboot diagnostic programs on page 143 for information about how to run diagnostics Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn ...

Страница 66: ...000 0000000000 0000000000 0000000000 0000000000 0000000000 0 0 0 0 0 0 0 0 0 0 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 Cover release latch Left side cover Figure 37 Left side cover removal Removing the air baffle Use this information to remove the air baffle from the ser...

Страница 67: ...tches and set it aside 0 00 00 0 0 0 0 00 00 Release latch Release latch Air baffle Figure 38 Air baffle removal Removing the fan cage assembly Use this information to remove the fan cage assembly from the server Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral...

Страница 68: ...ully open 0 00 00 0 0 0 0 0 00 00 00 1 2 Fan cage assembly Figure 39 Fan cage removal Step 7 Grasp the fan cage assembly and lift it out of the server Installing a hot swap fan Use this information to install a hot swap fan in the server Attention To avoid unexpected system shutdown ensure that you lay the server on its side with the cover facing up before you start The server comes with two 92 mm...

Страница 69: ...the server with the power on If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a hot swap fan complete the following steps Step 1 Carefully turn the server on its side so that it is lying flat with the cover facing up Step 2 Touch the static protective package that contains ...

Страница 70: ...e new drive You have checked the instructions that come with the new drive to determine whether you must set any switches or jumpers in the drive You have removed the optical drive rail from the side of the old drive and have them available for installation on the new drive Notes If you are installing a new DVD drive on the optical drive bay 2 an EMC shield should be removed firstly to continue th...

Страница 71: ... guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install the DVD drive complete the following steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 49 Step 2 Open the bezel see Opening the bezel door on page 47 Step 3 Rem...

Страница 72: ...retainer clip Note If the 1st drive retainer clip has been used slide out the 2nd drive retainer clip for use If you need an additional drive retainer clip you can purchase it from Lenovo For the part number of the drive retainer clip see Structural parts on page 174 2nd Drive retainer clip Figure 43 Slide out the 2nd drive retainer clip 56 System x3500 M5 Installation and Service Guide ...

Страница 73: ...e from the front and then attach the cables Step 9 Align the rail on the DVD drive with the guides in the drive bay then slide the DVD drive into the drive bay until it clicks into place 0 0 00 00 00 0 0 DVD drive Drive retainer clip Figure 45 Slide the DVD drive into the drive bay Step 10 Connect power and signal cables to the drive and the connectors on the system board see Internal cable routin...

Страница 74: ...r and peripheral devices and disconnect the power cords and all external cables To install an optional full height tape drive complete the following steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 49 Step 2 Open the bezel see Removing the bezel on page 184 Step 3 Remove the EMC shields from the drive bay if installed Step 4 Touch the static protective pa...

Страница 75: ...rive retainer clip Note If the 1st drive retainer clip has been used slide out the 2nd drive retainer clip for use If you need an additional drive retainer clip you can purchase it from Lenovo For the part number of the drive retainer clip see Structural parts on page 174 2nd Drive retainer clip Figure 47 Slide out the 2nd drive retainer clip Chapter 2 Installing optional devices 59 ...

Страница 76: ... drive from the front and then attach the cables Step 8 Align the tape drive with the drive bay then slide the tape drive into the drive bay until it clicks into place 0 0 00 00 00 0 0 Tape drive Drive retainer clip Figure 49 Slide the tape drive into the drive bay Step 9 Connect the power and signal cables to the drive and the connectors on the system board see Internal cable routing and connecto...

Страница 77: ... server model the server might come with a SATA attached DVD ROM drive in bay 1 Note If the server is configured for RAID operation using a ServeRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter The following illustrati...

Страница 78: ...n 2 5 inch hot swap hard disk drives 0 0 0 0 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 SATA SAS hard disk drive bays Figure 52 Server with twenty four 2 5 inch hot swap hard disk drives 62 System x3500 M5 Installatio...

Страница 79: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 SATA SAS hard disk drive bays Figure 53 Server with thirty two 2 5 inch hot swap hard disk drives The following illustrations show the location of the drive bays in the 3 5 inch simple swap or hot swap hard disk drive server models Chapter 2 Installing optional devices 63 ...

Страница 80: ...0 00 0 0 0 0 00 00 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 SATA SAS hard disk drive bays Figure 54 Server with six 3 5 inch hot swap hard disk drives 64 System x3500 M5 Installation and Service Guide ...

Страница 81: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 8 9 10 13 12 11 SATA SAS hard disk drive bays Figure 55 Server with twelve 3 5 inch hot swap hard disk drives Chapter 2 Installing optional devices 65 ...

Страница 82: ...ive bays Figure 56 Server with eight 3 5 inch simple swap hard disk drives The following illustrations show the location of the drive bays in the 2 5 inch and 3 5 inch hot swap or hot swap hard disk drive server models 66 System x3500 M5 Installation and Service Guide ...

Страница 83: ... 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 9 10 11 12 13 14 15 2 1 0 3 4 5 0 0 SATA SAS hard disk drive bays Figure 57 Server with six 3 5 inch hot swap and eight 2 5 inch hot swap hard disk drives Chapter 2 Installing optional devices 67 ...

Страница 84: ...ATA device be sure to set the SAS or SATA ID for that device Optional external tape drives and DVD ROM drives are examples of removable media drives You can install removable media drives only in bays 1 and 2 on models with six twelve 3 5 inch eight sixteen twenty four and thirty two 2 5 inch hard disk drives The electromagnetic interference EMI integrity and cooling of the server are protected by...

Страница 85: ...e wrist strap or other grounding system when you work inside the server with the power on Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a 2 5 inch hot swap hard disk drive complete the...

Страница 86: ... information about RAID operation and complete instructions for using ServeRAID manager Step 7 Close the bezel see Installing the bezel on page 186 Step 8 Lock the left side cover Installing a 3 5 inch hot swap hard disk drive Use this information to install a 3 5 inch hot swap SAS SATA hard disk drive Before installing a 3 5 inch hot swap hard disk drive read the following information Inspect the...

Страница 87: ...ot swap hard disk drive 3 5 inch filler panel Figure 60 Hot swap hard disk drive installation Step 7 Rotate the drive tray handle to the closed position Step 8 Check the hard disk drive status indicator to make sure that the hard disk drive is operating correctly After you replace a failed hard disk drive the green activity LED flashes as the disk spins up The yellow LED turns off after approximat...

Страница 88: ...power cords and all external cables To install a 3 5 inch simple swap hard disk drive complete the following steps Step 1 Turn off the server Step 2 Unlock the left side cover Note You must unlock the left side cover to open or remove the bezel When you lock the left side cover it locks both the cover and the bezel Step 3 Open the bezel see Opening the bezel door on page 47 Step 4 Remove the fille...

Страница 89: ...e DIMMs the server configuration information changes When you restart the server the system displays a message that indicates that the memory configuration has changed The server supports only industry standard double data rate 4 DDR4 1600 1866 or 2133 MHz PC4 12800 PC4 14900 or PC4 17000 registered or load deduction synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs w...

Страница 90: ...ng rules apply to DDR4 RDIMM speed as it relates to the number of RDIMMs in a channel When you install 1 RDIMM per channel the memory runs at 2133 MHz When you install 2 RDIMMs per channel the memory runs at 1866 MHz When you install 3 RDIMMs per channel the memory runs at 1600 MHz All channels in a server run at the fastest common frequency Do not install registered and load reduction DIMMs in th...

Страница 91: ...n the Setup utility For additional information see Configuring the server on page 104 A minimum of one DIMM must be installed for each microprocessor For example you must install a minimum of two DIMMs if the server has two microprocessors installed However to improve system performance install a minimum of four DIMMs for each microprocessor DIMMs in the server must be the same type RDIMM or LRDIM...

Страница 92: ...cy 1600 MHz Please refer to the Understanding and Optimizing Memory Performance for Intel Xeon Processor E5 2600 v3 Series in IBM Flex System System x and BladeCenter Platforms white paper for the detail Memory mirrored channel Memory mirrored channel mode replicates and stores data on two pairs of DIMMs within two channels simultaneously If a failure occurs the memory controller switches from the...

Страница 93: ...1 are filled The following table shows the installation sequence for memory mirrored mode Table 8 Memory mirrored channel mode DIMM population sequence Number of DIMMs Number of installed microprocessor DIMM connector First pair of DIMMs 1 1 4 Second pair of DIMMs 1 9 12 Third pair of DIMMs 1 2 5 Fourth pair of DIMMs 1 8 11 Fifth pair of DIMMs 1 7 10 Sixth pair of DIMMs 1 3 6 First pair of DIMMs 2...

Страница 94: ...etup utility on page 107 The memory rank sparing mode requires an even number of DIMMs If your server has an odd number of DIMMs installed ensure that you disable the memory rank sparing mode from the Memory menu in Setup Utility See Using the Setup utility on page 107 Note After disabling the memory rank sparing mode if a message prompts that the memory configuration is not valid restart the IMM2...

Страница 95: ...IMMs 2 23 24 Ninth pair of DIMMs 2 7 10 Tenth pair of DIMMs 2 19 22 Eleventh pair of DIMMs 2 3 6 Twelfth pair of DIMMs 2 15 18 Note Rank Sparing is only supported when there is more than 1DPC or if a single QRDIMM is installed Installing a DIMM Use this information to install a DIMM Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server...

Страница 96: ... the DIMM so that the alignment slot align correctly with the alignment tab Step 6 Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector see System board internal connectors on page 25 for the locations of the DIMM connectors Retaining clip DIMM Alignment slot Alignment tab Figure 66 Insert DIMM into connector 80 System x3500 M5 Insta...

Страница 97: ...haring of PCI interrupts Attention Static electricity that is released to internal server components when the server is powered on might cause the server to stop which might result in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when working inside the server with the power on Read the safety information in Safety on p...

Страница 98: ...ackets to the open position Step 9 Remove the PCIe slot filler if installed Keep the filler in a safe place for potential future use Step 10 Press the adapter firmly into the expansion slot 00 00 00 0 0 0 0 0 0 0 0 Expansion slot cover Adapter Bracket Back View Figure 68 Press adapter into expansion slot Attention Incomplete insertion might cause damage to the system board or the adapter Step 11 C...

Страница 99: ...cover on page 49 Step 2 Remove the air baffle see Removing the air baffle on page 188 Step 3 Locate the ServeRAID adapter which you will install the memory module Remove the ServeRAID adapter if necessary Step 4 Touch the static protective package that contains the memory card to any unpainted metal surface on the server then remove the memory card from the package Step 5 Align the memory module w...

Страница 100: ...he battery flash power module a Align the battery flash power module cable connector with the slot on the battery flash power module holder Place the battery flash power module into the battery flash power module holder and make sure that the battery flash power module holder engages the battery flash power module securely 1 2 Battery flash power module Battery holder Retention clip Figure 70 Alig...

Страница 101: ...frequency core frequency power segment internal cache size and type Mixing microprocessors of different stepping levels within the same server model is supported When mixing microprocessors with different stepping levels within the same server model you do not have to install the microprocessor with lowest stepping level and features in microprocessor socket 1 Both microprocessor voltage regulator...

Страница 102: ...vices on page 31 To replace a microprocessor and heat sink complete the following steps Step 1 Turn off the server and peripheral devices and disconnect the power cords and all external cables Step 2 Remove the left side cover see Removing the left side cover on page 49 Step 3 Remove the air baffle see Removing the air baffle on page 50 Step 4 If you are replacing microprocessor 1 remove the memor...

Страница 103: ...nd open it b Open the second release lever on the microprocessor socket c Open the microprocessor retainer Attention Do not touch the connectors on the microprocessor and the microprocessor socket Step 7 Install the microprocessor on the microprocessor socket a Touch the static protective package that contains the new microprocessor to any unpainted on the chassis or any unpainted metal surface on...

Страница 104: ...d Installation tool Microprocessor Alignment pins Figure 74 Installation tool alignment c Install the microprocessor using the following instructions for your installation tool Twist the handle of the installation tool assembly counterclockwise to the unlocked position until you can not twist the handle any further then lift the installation tool out of the socket Figure 75 Installation tool handl...

Страница 105: ... the socket Make sure that the microprocessor is oriented and aligned correctly in the socket before you try to close the microprocessor retainer Do not touch the thermal material on the bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it Step 8 Remove the cover from the retainer bracket if one is present Store the cover in a safe place Chapter...

Страница 106: ...cessor socket release levers and retainer 1 3 2 Microprocessor release lever Microprocessor release lever Figure 79 Microprocessor socket levers and retainer engagement a Close the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket Step 10 Insta...

Страница 107: ...grease Figure 80 Thermal grease a Remove the plastic protective cover from the bottom of the heat sink b Grasp the heat sink firmly to avoid possible damage to the heat sink c Position the heat sink over the microprocessor The heat sink is keyed to assist with proper alignment Heat sink Lock tab Retainer bracket tabs Heat sink release lever Figure 81 Heat sink installation d Align and insert the f...

Страница 108: ...vices and the server Thermal grease The thermal grease must be replaced whenever the heat sink has been removed from the top of the microprocessor and is going to be reused or when debris is found in the grease Use this information to replace damaged or contaminated thermal grease on the microprocessor and heat sink When you are installing the heat sink on the same microprocessor that it was remov...

Страница 109: ...roximately 5 mm of the edge of the microprocessor This is to ensure uniform distribution of the grease Figure 84 Thermal grease syringe Note 0 01 mL is one tick mark on the syringe If the grease is properly applied approximately half 0 22 mL of the grease will remain in the syringe Step 6 Install the heat sink onto the microprocessor as described in Installing a microprocessor and heat sink on pag...

Страница 110: ...iately You can order an optional power supply for redundancy These power supplies are designed for parallel operation In the event of a power supply failure the redundant power supply continues to power the system The server supports a maximum of two power supplies Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical cur...

Страница 111: ...and place it on a static protective surface Step 2 Remove the power supply filler panel from the power bay if one is installed 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Hot swap power supply filler panel Release latch Power supply 2 Power supply 1 Figure 85 Power supply filler panel removal Step 3 Install the power supply and push it in until it locks into place Notes 1 If only one hot swap power supply is in...

Страница 112: ...0 0000 0000 0000 0000 0000 0000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 00 000 000 000 000 Figure 86 Power supply replacement Installing a USB embedded hypervisor flash device Use this information to install a USB embedded hypervisor flash device Read the safety information in Safety on ...

Страница 113: ... installation Use this information to complete the installation To complete the installation complete the following steps Step 1 If you removed the fan cage assembly reinstall it see Replacing the fan cage assembly on page 98 Step 2 If you removed the air baffle reinstall it see Replacing the air baffle on page 99 Step 3 If you removed the left side cover replace it see Replacing the left side cov...

Страница 114: ... information in Safety on page v and Installation guidelines on page 29 To replace the fan cage assembly complete the following steps Step 1 Align the guides on the fan cage with the release latch to the open position on each side Step 2 Push the fan cage assembly into the server Note Make sure that the fan cage is fully seated Step 3 Rotate the fan cage release latch to the close position The fan...

Страница 115: ...000 0000000000000 0000000000000 0000000000000 0000000000000 0000000000000 0000000000000 Guide pins Air baffle Release latch Release latch Figure 90 Air baffle installation Replacing the left side cover Use this information to replace the left side cover Make sure that all cables adapters and other components are installed and seated correctly and that you have not left loose tools or parts inside ...

Страница 116: ...000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 Figure 91 Set the bottom edge of the left side cover Step 4 Lock the cover using the key that comes with the server Connecting the cables Use this information to connect the cables The following illustration shows the locations of the input...

Страница 117: ... tab DVD drive activity LED DVD drive eject button Hard disk drive activity LED green Hard disk drive status LED yellow System TPM physical presence button Figure 92 Front of server The following illustration shows the locations of the input and output connectors on the rear of the server Chapter 2 Installing optional devices 101 ...

Страница 118: ...formation to update the server configuration When you start the server for the first time after you add or remove a device you might receive a message that the configuration has changed The Setup utility starts automatically so that you can save the new configuration settings Some optional devices have device drivers that you must install For information about installing device drivers see the doc...

Страница 119: ...staller to acquire and apply UpdateXpress System Packs and individual firmware and device driver updates For additional information and to download the UpdateXpress System Pack Installer go to the ToolsCenter for System x and BladeCenter at https support lenovo com us en documents LNVO CENTER and click UpdateXpress System Pack Installer When you click an update an information page is displayed inc...

Страница 120: ...d the Integrated Management Module II User s Guide at http publib boulder ibm com infocenter systemx documentation topic com lenovo sysx imm2 doc printable_doc html VMware ESXi embedded hypervisor An optional USB flash device or SD card with VMware ESXi embedded hypervisor software is available for purchase Hypervisor is virtualization software that enables multiple operating systems to run on a h...

Страница 121: ...ation and applications for configuring and managing the RAID arrays Server configuration RAID array configuration before operating system is installed RAID array management after operating system is installed ServeRAID M5210 adapter MegaRAID BIOS HII MegaRAID Storage Manager MSM MegaCLI and Systems Director Notes 1 For more information about the Human Interface Infrastructure HII and SAS2IRCU go t...

Страница 122: ...program Typical operating system installation This section details the ServerGuide typical operating system installation The ServerGuide program can reduce the time it takes to install an operating system It provides the device drivers that are required for your hardware and for the operating system that you are installing This section describes a typical ServerGuide operating system installation ...

Страница 123: ...le Step 3 Select settings to view or change Setup utility menu choices Use the Setup utility main menu to view and configure server configuration data and settings The following choices are on the Setup utility main menu for the UEFI Depending on the version of the firmware some menu choices might differ slightly from these descriptions System Information Select this choice to view information abo...

Страница 124: ...nd power utilization Legacy Support Select this choice to view or set legacy support Note In the legacy mode this system has limited ROM space for installed options At most four network interface cards NICs are supported for legacy PXE boot If more than four NICs are installed legacy PXE boot will not be attempted on some of the NICs To enable legacy PXE boot on the desired NIC connectors prioriti...

Страница 125: ...is choice to view or change the system recovery parameters POST Attempts Select this choice to view or change the number of attempts to POST POST Attempts Limit Select this choice to view or change the Nx boot failure parameters System Recovery Select this choice to view or change system recovery settings POST Watchdog Timer Select this choice to view or enable the POST watchdog timer POST Watchdo...

Страница 126: ...e system event log contains POST and system management interrupt SMI events and all events that are generated by the baseboard management controller that is embedded in the Integrated Management Module II IMM2 Important If the system error LED on the front of the server is lit but there are no other error indications clear the system event log Also after you complete a repair or correct an error c...

Страница 127: ...up utility Starting the backup server firmware Use this information to start the backup server firmware The system board contains a backup copy area for the server firmware This is a secondary copy of the server firmware that you update only during the process of updating the server firmware If the primary copy of the server firmware becomes damaged use this backup copy To force the server to star...

Страница 128: ...n in a single chip The IMM2 1 supports the following basic systems management features Active Energy Manager Alerts in band and out of band alerting PET traps IPMI style SNMP e mail Auto Boot Failure Recovery ABR Automatic microprocessor disable on failure and restart in a two microprocessor configuration when one microprocessor signals an internal error When one of the microprocessors fail the se...

Страница 129: ... can also save one or more commands as a text file and run the file as a script Serial over LAN Establish a Serial over LAN SOL connection to manage servers from a remote location You can remotely view and change the UEFI settings restart the server identify the server and perform other management functions Any standard Telnet client application can access the SOL connection For more information a...

Страница 130: ...le of the 12 characters for example 5C F3 FC FF FE 5E AA D0 Step 5 Convert the first pair of hexadecimal characters to binary for example 5 0101 C 1100 which results in 01011100 F3 FC FF FE 5E AA D0 Step 6 Flip the 7th binary character from left 0 to 1 or 1 to 0 which results in 01011110 F3 FF FE 5E AA D0 Step 7 Convert the binary back to hexadecimal for example 5E F3FCFFFE5EAAD0 Obtaining the IP ...

Страница 131: ...ystem Status System State disable Windows 2008 or 2012 firewall or type the following command in the Windows 2008 or 2012 console This might also affect blue screen capture features netsh firewall set icmpsetting type 8 mode ENABLE By default the icmp packet is blocked by Windows firewall The IMM2 1 GUI will then change to OS booted status after you change the setting as indicated above in both th...

Страница 132: ...iation the controllers detect the data transfer rate 10BASE T 100BASE TX or 1000BASE T and duplex mode full duplex or half duplex of the network and automatically operate at that rate and mode You do not have to set any jumpers or configure the controllers However you must install a device driver to enable the operating system to address the controllers To find device drivers and information about...

Страница 133: ...wer version To locate and install a newer version of Systems Director complete the following steps Step 1 Check for the latest version of Systems Director a Go to http www ibm com systems software director resources html b If a newer version of Systems Director than what comes with the server is shown in the drop down list follow the instructions on the web page to download the latest version Step...

Страница 134: ... interface configuration and issuing setup commands through the command line interface Scripting environments through a batch processing mode Saving any of the settings as a file and running the file as a script For more information and to download the program go to https support lenovo com us en documents LNVO CENTER Using Lenovo XClarity Administrator The initial setup of Lenovo XClarity Adminis...

Страница 135: ...e link and download the correct version for your operating system Step 2 Lenovo ToolsCenter Suite CLI sets the UUID in the IMM2 1 Select one of the following methods to access the IMM2 1 to set the UUID Online from the target system such as LAN or keyboard console style KCS access Remote access to the target system LAN based Bootable medium containing Lenovo ToolsCenter Suite CLI LAN or KCS depend...

Страница 136: ... layer For more details see the Lenovo ToolsCenter Suite CLI Users Guide To access this guide do the following 1 Go to http www lenovo com support 2 Click the Downloads tab at the top of the panel 3 Under ToolsCenter select View ToolsCenter downloads 4 Select Lenovo ToolsCenter Suite CLI 5 Scroll down and click the link and download the correct version for your operating system Scroll down and loo...

Страница 137: ...t system such as LAN or keyboard console style KCS access Remote access to the target system LAN based Bootable medium containing Lenovo ToolsCenter Suite CLI LAN or KCS depending upon the bootable media Step 3 Copy and unpack the Lenovo ToolsCenter Suite CLI package which also includes other required files to the server Make sure that you unpack the Lenovo ToolsCenter Suite CLI and the required f...

Страница 138: ...use this access method The KCS access method uses the IPMI KCS interface This method requires that the IPMI driver be installed Some operating systems have the IPMI driver installed by default Lenovo ToolsCenter Suite CLI provides the corresponding mapping layer To download the Lenovo ToolsCenter Suite CLI Users Guide do the following 1 Go to http www lenovo com support 2 Click Downloads tab at th...

Страница 139: ...rodName m t_model host imm_ip onecli config set SYSTEM_PROD_DATA SysInfoSerialNum s n host imm_ip onecli config set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip Bootable media You can also build a bootable medium using the applications available through the ToolsCenter Web site at https support lenovo com us en documents LNVO CENTER From the ToolsCenter page scroll down for the availa...

Страница 140: ...124 System x3500 M5 Installation and Service Guide ...

Страница 141: ...rred If any hardware software or firmware was changed before the problem occurred if possible reverse those changes This might include any of the following items Hardware components Device drivers and firmware System software UEFI firmware System input power or network connections Step 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis of hardware an...

Страница 142: ...and running preboot diagnostics For more information about UpdateXpress System Packs see http www ibm com support entry portal docdisplay lndocid SERV XPRESS and Updating the firmware on page 103 For more information about the Bootable Media Creator see https support lenovo com us en documents LNVO BOMC Be sure to separately install any listed critical updates that have release dates that are late...

Страница 143: ... http www lenovo com support Step 8 Use the troubleshooting tables See Troubleshooting by symptom on page 145 to find a solution to a problem that has identifiable symptoms A single problem might cause multiple symptoms Follow the troubleshooting procedure for the most obvious symptom If that procedure does not diagnose the problem use the procedure for another symptom if possible If the problem r...

Страница 144: ...ed hard disk drive cluster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones that test the storage unit that is a hard disk drive in the storage unit or the storage adapter that is attached to the storage unit The failing server might be part of a cluster if any of the following conditions is true You have identified...

Страница 145: ...s an error follow the instructions in Appendix C DSA diagnostic test results on page 1041 If DSA does not report an error but you still suspect a problem see Solving undetermined problems on page 158 Diagnostic tools The following tools are available to help you diagnose and solve hardware related problems Light path diagnostics Use light path diagnostics to diagnose system errors quickly See Ligh...

Страница 146: ...es Kernel modules Light path diagnostics status Microprocessor input out hub and UEFI error logs Network interfaces and settings Option card driver and firmware information RAID controller configuration Service processor Integrated Management Module II IMM2 status and configuration System configuration Vital product data firmware and UEFI configuration DSA Portable creates a DSA log which is a chr...

Страница 147: ...mory modules 5 Microprocessors 6 Optical devices CD or DVD 7 SAS or SATA drives 8 LSI controller 9 Broadcom network adapter 10 FusionIO storage 11 Intel GPU 12 Nvidia GPU See Running DSA Preboot diagnostic programs on page 143 for more information on running the DSA Preboot program on the server Troubleshooting by symptom These tables list problem symptoms and actions to correct the problems See T...

Страница 148: ... the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a Trained technician Go to the IBM support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Table 1...

Страница 149: ...technician only that step must be performed only by a Trained technician Go to the IBM support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Table 12 Light path diagnostics panel LEDs LED Description Action Hard disk drive RAID A hard disk drive has failed or is missing A SAS controller or a ServeR...

Страница 150: ...led correctly See Installing a microprocessor and heat sink on page 276 for information about installation and requirements 2 Trained technician only Replace the failing microprocessor see Installing a microprocessor and heat sink on page 276 3 If the failure remains go to http www lenovo com support Microprocessor Microprocessor Configuration When both the Microprocessor and Configuration LEDs ar...

Страница 151: ... configuration error has occurred If the Configuration LED and the Power supply LED are lit the system issues an invalid power configuration error Make sure that both power supplies installed in the server are of the same rating or wattage When only the Memory LED is lit a memory error has occurred Note Each time you install or remove a DIMM you must disconnect the server from the power source the...

Страница 152: ...the following steps in order until the problem is solved 1 Add a second power supply 2 Replace the failed power supply 3 Remove the optional devices PCI An error has occurred on a PCI card or a PCI bus 1 Check if any PCI slot error LED is lit to identify the component that caused the error 2 Check the system error log for information about the error see Event logs on page 139 3 If you cannot isola...

Страница 153: ...ics panel This information can often provide enough information to diagnose the error Power supply LEDs This section describes the power supply LEDs on the rear of the server and the suggested actions to correct the detected problems The following illustration shows the power supply LEDs on the rear of the server Figure 95 Power supply LEDs on the rear of the server 00 00 00 00 00 00 00 000 000 00...

Страница 154: ...er supply Off On On Faulty power supply Replace the power supply On Off Off Power supply not fully seated faulty system board or faulty power supply 1 Reseat the power supply 2 If the system board error LED is not lit replace the power supply 3 Trained technician only If the system board error LED is lit replace the system board Typically indicates that a power supply is not fully seated On Off or...

Страница 155: ...Module II IMM2 You can view the contents of the system event log through the Setup utility and through the Dynamic System Analysis DSA program as IPMI event log The system event log is limited in size When it is full new entries will not overwrite existing entries therefore you must periodically clear the system event log through the Setup utility When you are troubleshooting an error you might ha...

Страница 156: ...nalysis DSA Portable you can use it to view the system event log as the IPMI event log or the IMM2 1 event log as the ASM event log the operating system event logs or the merged DSA log You can also use DSA Preboot to view these logs although you must restart the server to use DSA Preboot To install DSA Portable or check for and download a later version of DSA Preboot CD image go to https support ...

Страница 157: ...grams on page 143 for more information Alternatively you can restart the server and press F1 to start the Setup utility and view the POST event log or system event log For more information see Viewing event logs through the Setup utility on page 140 Clearing the event logs Use this information to clear the event logs To clear the event logs complete the following steps Note The POST error log is a...

Страница 158: ...boot might appear to be unresponsive when you start the program This is normal operation while the program loads Make sure that the server has the latest version of the DSA code To obtain DSA code and the Dynamic System Analysis Installation and User s Guide go to https support lenovo com us en documents LNVO DSA DSA editions Two editions of Dynamic System Analysis are available DSA Portable DSA P...

Страница 159: ...urn off the server and all attached devices Step 2 Turn on all attached devices then turn on the server Step 3 When the prompt F2 Diagnostics is displayed press F2 Note The DSA Preboot diagnostic program might appear to be unresponsive for an unusual length of time when you start the program This is normal operation while the program loads The loading process may take up to 10 minutes Step 4 Optio...

Страница 160: ...ections to an external USB device type the copy command in the DSA interactive menu If you are running the DSA graphical user interface GUI click the Success link in the Status column If you are running the DSA interactive menu CLI type x to exit the Execute Tests menu then select completed tests to view the results You can also send the DSA error log to Lenovo support to aid in diagnosing the ser...

Страница 161: ...g correctly for information about using DSA see Appendix C DSA diagnostic test results on page 1041 Step 4 Reinstall the new software or new device CD DVD drive problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a Trained technician ...

Страница 162: ...ined technician The server is hung while the screen is on Cannot start the Setup utility by pressing F1 1 See Nx boot failure on page 162 for more information 2 See Recovering the server firmware UEFI update failure on page 160 for more information GPU VGA adapter problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an acti...

Страница 163: ...ograms on page 143 Note This test is not available on servers that have RAID arrays or servers that have SATA hard disk drives Hypervisor problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a Trained technician Go to the IBM support w...

Страница 164: ...ptom Action All or some keys on the keyboard do not work 1 Make sure that The keyboard cable is securely connected The server and the monitor are turned on 2 If you are using a USB keyboard run the Setup utility and enable keyboardless operation 3 If you are using a USB keyboard and it is connected to a USB hub disconnect the keyboard from the hub and connect it directly to the server 4 Replace th...

Страница 165: ...rse the DIMMs between the channels of the same microprocessor and then restart the server If the problem is related to a DIMM replace the failing DIMM 6 Re enable all DIMMs using the Setup utility and then restart the server 7 Trained technician only Install the failing DIMM into a DIMM connector for microprocessor 2 if installed to verify that the problem is not the microprocessor or the DIMM con...

Страница 166: ...ation System Summary Processor Details 3 Trained technician only Reseat microprocessor 1 4 Trained technician only If there is no indication of which microprocessor has failed isolate the error by testing with one microprocessor at a time 5 Replace the following components one at a time in the order shown restarting the server each time a Trained technician only Microprocessor 2 b Trained technici...

Страница 167: ...t the screen goes blank when you start some application programs 1 Make sure that The application program is not setting a display mode that is higher than the capability of the monitor You installed the necessary device drivers for the application 2 Run video diagnostics see Running DSA Preboot diagnostic programs on page 143 If the server passes the video diagnostics the video is good see Solvin...

Страница 168: ...Log in failed by using LDAP account with SSL enabled 1 Make sure the license key is valid 2 Generate a new license key and log in again Optional device problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a Trained technician Go to the...

Страница 169: ...d actions Symptom Action The power control button does not work and the reset button does not work the server does not start Note The power control button will not function until approximately 5 to 10 seconds after the server has been connected to power 1 Make sure that the power control button is working correctly a Disconnect the server power cords b Reconnect the power cords c Trained technicia...

Страница 170: ...m remains or if you are using an ACPI aware operating system suspect the system board The server unexpectedly shuts down and the LEDs on the operator information panel are not lit See Solving undetermined problems on page 158 Serial port problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trai...

Страница 171: ...ned technician only that step must be performed only by a Trained technician Go to the IBM support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Table 30 ServerGuide problems and actions Symptom Action The ServerGuide Setup and Installation CD will not start 1 Make sure that the server supports the...

Страница 172: ...tion hints tips and new device drivers or to submit a request for information Table 31 Software problems and actions Symptom Action You suspect a software problem 1 To determine whether the problem is caused by the software make sure that The server has the minimum memory that is needed to use the software For memory requirements see the information that comes with the software If you have just in...

Страница 173: ...onnect the cables and power cords to all internal and external devices until the server is at the minimum configuration that is required for the server to start see Solving undetermined problems on page 158 Step 5 Reconnect all ac power cords and turn on the server If the server starts successfully reseat the adapters and devices one at a time until the problem is isolated If the server does not s...

Страница 174: ...rver are using the same protocol If the Ethernet controller still cannot connect to the network but the hardware appears to be working the network administrator must investigate other possible causes of the error Solving undetermined problems If Dynamic System Analysis DSA cannot diagnose the failure or if the server is inoperative use the information in this section to solve the undetermined prob...

Страница 175: ...t occurs When Where Does the failure occur on a single server or on multiple servers Is the failure repeatable Has this configuration ever worked What changes if any were made before the configuration failed Is this the original reported failure Diagnostic program type and version level Hardware configuration print screen of the system summary UEFI firmware level IMM firmware level Operating syste...

Страница 176: ... bank and a backup bank You must maintain a bootable UEFI firmware image in the backup bank If the server firmware in the primary bank becomes corrupted you can either manually boot the backup bank with the UEFI boot backup jumper JP2 or in the case of image corruption this will occur automatically with the Automated Boot Recovery function In band manual recovery method This section details the in...

Страница 177: ...n details the in band automated boot recovery method Note Use this method if the System board LED on the light path diagnostics panel is lit and there is a log entry or Booting Backup Image is displayed on the firmware splash screen otherwise use the in band manual recovery method Step 1 Boot the server to an operating system that is supported by the firmware update package that you downloaded Ste...

Страница 178: ...server to attempt POST again After a specified number of consecutive attempts automatic or manual the Nx boot failure feature causes the server to revert to the default UEFI configuration and start the Setup utility so that you can make the necessary corrections to the configuration and restart the server If the server is unable to successfully complete POST with the default configuration there mi...

Страница 179: ... page 174 for the list of structural parts Tier 1 customer replaceable unit CRU Replacement of Tier 1 CRUs is your responsibility If Lenovo installs a Tier 1 CRU at your request you will be charged for the installation Tier 2 customer replaceable unit You may install a Tier 2 CRU yourself or request Lenovo to install it at no additional charge under the type of warranty service that is designated ...

Страница 180: ...bers for the server replaceable components Index Description CRU part number Tier 1 CRU part number Tier 2 1 System x3500 M5 Lightpath Upgrade Kit 81Y7098 2 Operator information panel assembly 81Y7083 3 Front USB assembly cable 94Y6367 7 Half High SATA DVD ROM 43W8466 7 HH Multi burner DVD 43W8467 25 System board IBM 00AL597 25 System board Lenovo 00MW076 25 System board Lenovo 01KN185 26 Heat Sin...

Страница 181: ...30MB 2133MHz 105W 00KJ034 E5 2683 v3 14C 2 0GHz 35MB Cache 2133MHz 120W Addl E5 2683 v3 14C 2 0GHz 35MB 2133MHz 120W 00KG110 E5 2685 v3 12C 2 6GHz 30MB Cache 2133MHz 120W Addl E5 2685 v3 12C 2 6GHz 30MB 2133MHz 120W 00KJ036 E5 2697 v3 14C 2 6GHz 35MB Cache 2133MHz 145W 00AE680 E5 2695 v3 14C 2 3GHZ 35MB Cache 2133MHz 120W Addl E5 2695 v3 14C 2 3GHZ 35MB 2133MHz 120W 00AE681 E5 2698 v3 16C 2 3GHz 4...

Страница 182: ... Power Cord Taiwan AC plug 15A 125V 2 8M 39M5463 2 8m 13A 125 10A 250V C13 to IEC 320 C14 Rack Power Cable 39M5509 2 8m 13A 120V C13 to NEMA 5 15P US Line Cord 39M5512 M5200 Series 1GB Flash RAID 5 Upgrade PRADA 47C8661 M5200 Series 1GB Flash RAID 5 Upgrade RAYBAN 47C8665 21 FAN cage Assembly 81Y7086 Kill Switch Assembly 00YL759 Slide cover Assembly 00YL760 Rubber kit 00YL761 22 Hot swap Fan 92x38...

Страница 183: ...upply 00YL557 34 750W Artesyn Titanium Power Supply 00YL559 34 750W Acbel Titanium Power Supply 00YL561 34 750W Emerson Titanium Power Supply 94Y8283 34 750W Emerson Platinum Power Supply 94Y8284 34 750W Acbel Titanium Power Supply 94Y8292 34 750W Delta Platinum Power Supply 94Y8297 34 750W Platinum AC Power Supply Artesyn 00YL565 34 750W Titanium AC Power Supply Artesyn 00YL569 34 750W High Effic...

Страница 184: ...3HS HDD 00NA527 S3700 200GB SATA 2 5 MLC G3HS Enterprise SSD 00AJ157 S3700 200GB SATA 3 5 MLC HS Enterprise SSD 00AJ481 S3700 400GB SATA 2 5 MLC G3HS Enterprise SSD 00AJ162 S3700 400GB SATA 3 5 MLC HS Enterprise SSD 00AJ486 S3700 800GB SATA 2 5 MLC G3HS Enterprise SSD 00AJ167 S3700 800GB SATA 3 5 MLC HS Enterprise SSD 00AJ491 200GB 12G SAS 2 5 MLC G3HS Enterprise SSD 00FN380 400GB 12G SAS 2 5 MLC ...

Страница 185: ...ise Entry SSD 00WG636 S3710 200GB SATA 2 5 G3HS Enterprise Performance SSD 00YC321 S3710 400GB SATA 2 5 G3HS Enterprise Performance SSD 00YC326 S3710 800GB SATA 2 5 G3HS Enterprise Performance SSD 00YC331 S3510 120GB SATA 3 5 HS Enterprise Entry SSD 00WG771 S3510 240GB SATA 3 5 HS Enterprise Entry SSD 00WG776 S3510 480GB SATA 3 5 HS Enterprise Entry SSD 00WG781 S3710 200GB SATA 3 5 HS Enterprise P...

Страница 186: ... port HBA Adapter 00JY847 Emulex 8Gb FC Dual port HBA Adapter 00JY848 Emulex 16Gb FC Dual port HBA Adapter 00JY849 Mellanox ConnectX 3 40GbE FDR IB VPI Adapter 00D9552 Mellanox ConnectX 3 10 GbE Adapter 00D9692 Broadcom NetXtreme 2x10GbE BaseT Adapter 00E2714 VFA5 2x10 GbE SFP PCIe Adapter 00JY823 VFA5 2x10 GbE SFP Adapter and FCoE iSCSI SW 00JY833 SAS HD 250mm Cable 00FK817 Keyboard US Eng 103P 0...

Страница 187: ...2K 12Gbps NL SAS 3 5 G2HS 512e HDD 00FN189 10 11 4TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e HDD 00FN209 10 11 6TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e HDD 00FN229 10 11 8TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e HDD 00WH122 10 11 2TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 00FN239 10 11 4TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 00FN249 10 11 6TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e SED 00FN259 10 11 10TB SAS 3 5 G2HS 512...

Страница 188: ...9M5392 4 3m 13A 125 10A 250V C13 to IEC 320 C14 Rack Power Cable 39M5510 Int HH LTO Gen 6 SAS Tape Drive 35P1049 HH LTO Gen 6 Internal SAS Tape Drive 00MW716 12Gb SAS Cable for LTO Tape Drive 00MW108 Blk 350mm CAT5 Cable 41Y9299 QLogic 10Gb SFP SR Optical Transceiver 42C1816 Emulex 16Gb FC Single port HBA 01CV833 Emulex 16Gb FC Dual port HBA 01CV843 SAS cable 43W8496 1M USB DDS6 Cable 44E8893 HD S...

Страница 189: ...mory 2Rx8 1 2V PC4 17000 CL15 2133MHz LP RDIMM 46W0794 28 32GB TruDDR4 Memory 4Rx4 1 2V PC417000 CL15 2133MHz LP LRDIMM 46W0802 28 64GB TruDDR4 Memory 4Rx4 1 2V PC4 17000 CL15 2133MHz LP LRDIMM 95Y4814 M5200 Series 1GB Cache RAID 5 Upgrade 47C8657 M5200 Series 4GB Flash RAID 5 Upgrade 47C8669 N2215 SAS SATA HBA 47C8676 N2225 SAS SATA HBA 00AE914 N2226 SAS SATA HBA 00KH483 Solarflare SFN7122F 2x10G...

Страница 190: ...xGbE BaseT Adapter 00AG522 Intel I350 F1 1xGbE Fiber Adapter 00AG502 Broadcom NetXtreme Dual Port 10GbE SFP Adapter 94Y5182 UltraNav Keyboard USB 94Y6108 Keyboard USB US ENG 103P 00MW364 Pref Pro Keyboard USB US English 103P RoHS v2 00AL883 Optim 200 G3HS 00AJ208 Optim 400 G3HS 00AJ213 Alcohol Wipe 00MP352 59P4739 Structural parts Structural parts are not covered by the Lenovo Statement of Limited...

Страница 191: ...7084 Fixed Side Cover 81Y7085 24 Air Duct Asm 81Y7088 6 Bezel Asm 81Y7089 Top Cover Asm 81Y7090 6 Auxiliary Hex Hole 81Y7091 EIA Bracket Assembly Kit 81Y7103 32 CFF PSU Filler 94Y7610 Top Pull Handle 00MU211 M3x3 screws 42C3934 Cable management arm 68Y7213 12 3 5 Simple Swap Filler 69Y5368 33 Fixed PBD Filler 81Y7099 PCI Bracket Top 00YL736 PCI Bracket Bottom 00YL737 To order a structural part com...

Страница 192: ...a Algeria Andorra Angola Armenia Austria Azerbaijan Belarus Belgium Benin Bosnia and Herzegovina Bulgaria Burkina Faso Burundi Cambodia Cameroon Cape Verde Central African Republic Chad Comoros Congo Democratic Republic of Congo Republic of Cote D Ivoire Ivory Coast Croatia Republic of Czech Republic Dahomey Djibouti Egypt Equatorial Guinea Eritrea Estonia Ethiopia Finland France French Guyana Fre...

Страница 193: ...la 39M5081 110 120 V Antigua and Barbuda Aruba Bahamas Barbados Belize Bermuda Bolivia Caicos Islands Canada Cayman Islands Colombia Costa Rica Cuba Dominican Republic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Mexico Micronesia Federal States of Netherlands Antilles Nicaragua Panama Peru Philippines Saudi Arabia Thailand Taiwan United States of America Venezuela 39M5076 39M5512 Uni...

Страница 194: ...178 System x3500 M5 Installation and Service Guide ...

Страница 195: ...ranty and getting service and assistance see the Warranty Information document that comes with the server For more information about getting service and assistance see Appendix D Getting help and technical assistance on page 1199 Returning a device or component If you are instructed to return a device or component follow all packaging instructions and use any packaging materials for shipping that ...

Страница 196: ...ep 3 Open the bezel door by pressing the button on the left edge of the bezel door and rotate the left side of the bezel door away from the server 00 00 00 Release button Figure 98 Open the bezel door 180 System x3500 M5 Installation and Service Guide ...

Страница 197: ...d Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To close the bezel door complete the following steps Step 1 Swing the bezel door to close it Step 2 From the left top section of the bezel door use the key to turn the tab down to lock the left side ...

Страница 198: ...ll optional hardware devices make sure that the server is working correctly Start the server and make sure that the operating system starts if an operating system is installed or that a 19990305 error code is displayed indicating that an operating system was not found but the server is otherwise working correctly If the server is not working correctly see Running DSA Preboot diagnostic programs on...

Страница 199: ...000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 Cover release latch Left side cover Figure 102 Left side cover removal Installing the left side cover Use this information to install the left side cover Read the safety information in Safety on page v and Installation guidelines o...

Страница 200: ...000000 000000000000 000000000000 000000000000 Figure 103 Set the bottom edge of the left side cover Step 4 Lock the cover using the key that comes with the server Removing the bezel Use this information to remove the bezel Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and ...

Страница 201: ...ase button Figure 105 Open the bezel Step 4 Pull the hinge assemblies hardly to release the bezel out of the server chassis Note The bezel hinge needs to remove at a specific angle around sixty degree Without doing so the hinge or even the bezel will get damaged You may find a white line on hinge as an indicator To remove bezel needs to align the white line first Chapter 6 Removing and replacing c...

Страница 202: ...nent in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install the bezel complete the following steps Step 1 Unlock the left side cover using the key that comes with the server Note You must unlock the left side cover to open or remove the bezel When you lock the left side cover it locks both the cover and the bezel Step ...

Страница 203: ...s and all external cables To replace the stabilizing feet complete the following steps Step 1 Turn off the server and peripheral devices and disconnect the power cords and all external cables Step 2 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to fall over Step 3 Carefully position the server on a flat surface with the fe...

Страница 204: ...ices and disconnect the power cords and all external cables Attention The server automatically powers off when the air baffle is removed To remove the air baffle complete the following steps Step 1 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to fall over Step 2 Unlock and remove the left side cover see Removing the left ...

Страница 205: ...cing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables Attention The server automatically powers off when the air baffle is removed To replace the air baffle complete the following steps Step 1 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow th...

Страница 206: ...attery or flash power module holder Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To remove a RAID adapter battery or flash power module holder complete the following steps Step 1 Carefully turn ...

Страница 207: ...tall a RAID adapter battery or flash power module holder Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a RAID adapter battery or flash power module holder complete the following steps ...

Страница 208: ...he battery or flash power module holder is secured firmly Step 6 Reinstall the air baffle see Replacing the air baffle on page 189 Step 7 Install and lock the left side cover see Installing the left side cover on page 183 If you have replaced a server component or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and per...

Страница 209: ...ion of the drive bays in the server Your hardware might differ depending on the model Note If the server is configured for RAID operation using a ServeRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter The following illu...

Страница 210: ...th sixteen 2 5 inch hard disk drives 0 0 0 0 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 00 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 SATA SAS hard disk drive bays Figure 114 Server with twenty four 2 5 inch hard disk drives 194 System x3500 M5 Installation and S...

Страница 211: ... 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 SATA SAS hard disk drive bays Figure 115 Server with thirty two 2 5 inch hard disk drives The following illustrations show the location of the drive bays in the 3 5 inch hot swap SAS or hot swap SATA hard disk drive server models Chapter 6 Removing and replacing components 195 ...

Страница 212: ...0 00 00 0 0 0 0 00 00 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 SATA SAS hard disk drive bays Figure 116 Server with six 3 5 inch hard disk drives 196 System x3500 M5 Installation and Service Guide ...

Страница 213: ...3 4 5 8 9 10 13 12 11 SATA SAS hard disk drive bays Figure 117 Server with twelve 3 5 inch hard disk drives The following illustrations show the location of the drive bays with both 2 5 inch and 3 5 inch hot swap SAS or hot swap SATA hard disk drive server models Chapter 6 Removing and replacing components 197 ...

Страница 214: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 9 10 11 12 13 14 15 2 1 0 3 4 5 0 0 SATA SAS hard disk drive bays Figure 118 Server with eight 2 5 inch hard disk drives and six 3 5 inch hard disk drives 198 System x3500 M5 Installation and Service Guide ...

Страница 215: ...t device Optional external tape drives and DVD ROM drives are examples of removable media drives You can install removable media drives only in bays 1 and 2 on models with six 3 5 inch eight sixteen twenty four and thirty two 2 5 inch hard disk drives The electromagnetic interference EMI integrity and cooling of the server are protected by having all bays and PCI slots covered or occupied When you...

Страница 216: ...120 Hot swap hard disk drive removal If you are instructed to return the server component or optional device follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing a 2 5 inch hot swap hard disk drive Use this information to install a 2 5 inch hot swap hard disk drive The following notes describe the types of hard disk drives that the serv...

Страница 217: ...ormation in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a 2 5 inch hot swap hard disk drive complete the following steps Step 1 Unlock the left side cover Note You must unlock the left side cover to open or remove...

Страница 218: ...dditional information about RAID operation and complete instructions for using ServeRAID manager Step 7 Close the bezel see Installing the bezel on page 186 Step 8 Lock the left side cover Removing a 3 5 inch hot swap hard disk drive Use this information to remove a 3 5 inch hot swap SAS SATA hard disk drive Attention To maintain proper system cooling do not operate the server for more than 10 min...

Страница 219: ...5 inch hot swap hard disk drive Use this information to install a 3 5 inch hot swap SAS SATA hard disk drive Before installing a 3 5 inch hot swap hard disk drive read the following information Inspect the drive tray for signs of damage To maintain proper system cooling do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each drive bay You do no...

Страница 220: ...ate the drive handle to the closed position Step 8 Check the hard disk drive status indicator to make sure that the hard disk drive is operating correctly After you replace a failed hard disk drive the green activity LED flashes as the disk spins up The yellow LED turns off after approximately 1 minute If the new drive starts to rebuild the yellow LED flashes slowly and the green activity LED rema...

Страница 221: ...the left side cover it locks both the cover and the bezel Step 3 Open the bezel see Removing the bezel on page 184 Step 4 Press the release latch to open the drive handle Then to grasp the drive handle and pull the hard disk drive out of the drive bay 0 0 00 00 0 0 0 00 00 0 0 0 0 0 0 0 0 0 0 0 0 Handle Latch 3 5 inch simple swap hard disk drive 3 5 inch filler panel Figure 124 Simple swap hard di...

Страница 222: ...e left side cover it locks both the cover and the bezel Step 3 Open the bezel see Removing the bezel on page 184 Step 4 Remove the filler panel if one is present Step 5 Touch the static protective package that contains the disk drive to any unpainted metal surface on the server then remove the disk drive from the package and place it on a static protective surface Step 6 Grasp the black drive hand...

Страница 223: ... DVD drive cables from the back of the DVD drive see Internal cable routing and connectors on page 33 Step 4 Grasp each side of the DVD drive to pull the drive out of the server 0 0 00 00 00 0 0 Release buttons DVD drive Figure 126 Pull the DVD drive out Step 5 Remove the optical drive retainer clip from the DVD drive and save them for future use If you are instructed to return the server componen...

Страница 224: ...Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server compon...

Страница 225: ... retainer clip Note If the 1st drive retainer clip has been used slide out the 2nd drive retainer clip for use If you need an additional drive retainer clip you can purchase it from Lenovo For the part number of the drive retainer clip see Structural parts on page 174 2nd Drive retainer clip Figure 128 Slide out the 2nd drive retainer clip Chapter 6 Removing and replacing components 209 ...

Страница 226: ...the new drive from the front and then attach the cables Step 7 Align the DVD drive to the drive bay then slide the DVD drive into the drive bay until it clicks into place 0 0 00 00 00 0 0 DVD drive Drive retainer clip Figure 130 Slide the DVD drive into the drive bay Step 8 Connect power and signal cables to the drive and the connectors on the system board see Internal cable routing and connectors...

Страница 227: ...e Removing the left side cover on page 182 Step 2 Open the bezel see Removing the bezel on page 184 Step 3 Disconnect the power and signal cables from the back of the tape drive see Internal cable routing and connectors on page 33 Step 4 Grasp both sides of the tape drive to pull the drive out of the drive bay from the server 0 0 00 00 00 0 0 Release buttons Tape drive Figure 131 Slide the tape dr...

Страница 228: ...ing steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 2 Open the bezel see Removing the bezel on page 184 Step 3 Remove the EMC shields from the drive bay if installed Step 4 Touch the static protective package that contains the tape drive to any unpainted metal surface on the server then remove the tape drive from the package 212 System x3500 M5 ...

Страница 229: ... retainer clip Note If the 1st drive retainer clip has been used slide out the 2nd drive retainer clip for use If you need an additional drive retainer clip you can purchase it from Lenovo For the part number of the drive retainer clip see Structural parts on page 174 2nd Drive retainer clip Figure 133 Slide out the 2nd drive retainer clip Chapter 6 Removing and replacing components 213 ...

Страница 230: ... drive from the front and then attach the cables Step 8 Align the tape drive with the drive bay then slide the tape drive into the drive bay until it clicks into place 0 0 00 00 00 0 0 Tape drive Drive retainer clip Figure 135 Slide the tape drive into the drive bay Step 9 Connect the power and signal cables to the drive and the connectors on the system board see Internal cable routing and connect...

Страница 231: ...allow the server to fall over Step 2 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 3 Remove the air baffle see Removing the air baffle on page 188 Step 4 Disconnect the cables from the adapter see Internal cable routing and connectors on page 33 Step 5 Press down the adapter retention brackets to the open position 000000000 000000000 000000000 000000000 00...

Страница 232: ... loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when working inside the server with the power on Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords an...

Страница 233: ...igure 137 Rotate the adapter retention brackets to the open position Step 8 Remove the expansion slot cover if installed Keep the slot cover in a safe place for potential future use Step 9 Press the adapter firmly into the expansion slot Attention Incomplete insertion might cause damage to the system board or the adapter Step 10 Close the adapter retention bracket Step 11 Connect the adapter cable...

Страница 234: ...c electricity that is released to internal server components when the server is powered on might cause the server to stop which might result in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when working inside the server with the power on Read the safety information in Safety on page v and Installation guidelines on pag...

Страница 235: ...video adapter that you install in the server Avoid touching the components and gold edge connectors on the adapter The server uses a rotational interrupt technique to configure PCI adapters so that you can install PCI adapters that do not support sharing of PCI interrupts Attention Static electricity that is released to internal server components when the server is powered on might cause the serve...

Страница 236: ...r on page 183 Step 11 Slide the server into the rack Step 12 See http www ibm com support entry portal docdisplay lndocid MIGR 5096845 for information about how to configure the SD adapter Step 13 Turn on the peripheral devices and the server Removing a remotely installed RAID adapter battery or flash power module Use this information to remove a RAID adapter battery or flash power module remotely...

Страница 237: ...sh power module remotely in the server Use this information to install a RAID adapter battery or flash power module remotely in the server Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables Note When ...

Страница 238: ...Align the battery flash power module cable to slot of the battery holder Place the battery flash power module into the battery holder and make sure that the battery holder engages the battery flash power module securely 1 2 Battery flash power module Battery holder Retention clip Figure 142 Align the battery flash power module cable Note The positioning of the remote battery flash power module dep...

Страница 239: ...external cables To remove an optional ServeRAID adapter memory module complete the following steps Step 1 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to fall over Step 2 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 3 Remove the air baffle see Removing the air baffle on page 188 ...

Страница 240: ...inted metal surface on the server then remove the memory card from the package Step 6 Align the memory module with the connector on the ServeRAID adapter and push it into the connector until it is firmly seated ServeRAID adapter Retention bracket ServeRAID memory module Figure 144 Align the memory module Step 7 Reinstall the ServeRAID adapter see Installing an adapter on page 216 Step 8 Reinstall ...

Страница 241: ...s use an electrostatic discharge wrist strap or other grounding system when you work inside the server with the power on Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To remove a hot swap fan com...

Страница 242: ...ata To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when you work inside the server with the power on Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all ext...

Страница 243: ...t side cover see Replacing the left side cover on page 99 If you have replaced a server component or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices Removing the system battery Use this information to remove the system battery The following illustration shows the location of the system battery Ba...

Страница 244: ...attery cover from the battery connector b Use one finger to tilt the battery horizontally out of its socket pushing it away from the socket Attention Neither tilt nor push the battery by using excessive force c Use your thumb and index finger to lift the battery from the socket Figure 149 System battery removal Attention Do not lift the battery by using excessive force Failing to remove the batter...

Страница 245: ...reset the system date and time To avoid possible danger read and follow the following safety statement Statement 2 CAUTION When replacing the lithium battery use only Lenovo Part Number 33F8354 or an equivalent type battery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery con...

Страница 246: ...eplacing the air baffle on page 189 Step 4 Install and lock the left side cover see Installing the left side cover on page 183 Step 5 Reconnect the external cables and power cords then turn on the attached devices and turn on the server Note You must wait approximately 3 minutes after you connect the server power cord to an electrical outlet before the power control button becomes active Step 6 St...

Страница 247: ...onnectors on page 33 Step 6 Pull the release latch and push backward the light path diagnostics assembly to the rear of the server to release it 0 0 0 1 2 Light path diagnostics assembly Release latch Figure 152 Remove the light path diagnostics assembly Step 7 Stand the server back up in its vertical position If you are instructed to return the server component or optional device follow all packa...

Страница 248: ...ight path diagnostics cable to the system board See System board internal connectors on page 25 and Internal cable routing and connectors on page 33 to locate the light path diagnostics connectors on the system board Step 8 Install the fan cage assembly see Installing the fan cage assembly on page 262 Step 9 Install the air baffle see Replacing the air baffle on page 189 Step 10 Install and lock t...

Страница 249: ... 6 Open the bezel door see Opening the bezel door on page 179 Step 7 Press down on the release latch of the USB assembly then rotate it to be released away from the server 1 2 Front USB assembly Release latch Figure 154 The USB assembly removal If you are instructed to return the server component or optional device follow all packaging instructions and use any packaging materials for shipping that...

Страница 250: ...tallation Step 9 Rotate and insert the USB cable assembly into the mounting bracket Step 10 Connect the USB cable to the system board see System board internal connectors on page 25 and Internal cable routing and connectors on page 33 Step 11 Close the bezel see Installing the bezel on page 186 Step 12 Reinstall the air baffle see Replacing the air baffle on page 189 Step 13 Install and lock the l...

Страница 251: ...e button Figure 156 Open bezel Step 3 Remove the 2 5 inch hot swap hard disk drives see Removing a 2 5 inch hot swap hard disk drive on page 199 Step 4 Remove the air baffle see Removing the air baffle on page 188 Step 5 Remove the fan cage assembly see Removing the fan cage assembly on page 261 Step 6 Note where the power signal and configuration cables are connected to the 2 5 inch hard disk dri...

Страница 252: ...2 5 inch HDD hot swap backplane expander 2 5 inch HDD hot swap backplane Figure 157 The location of 2 5 inch HDD hot swap backplanes Step 8 Lift the release latches that hold the backplane in place then rotate the top edge of the backplane toward the rear of the server and remove it from the server 236 System x3500 M5 Installation and Service Guide ...

Страница 253: ...ed to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a 2 5 inch hard disk drive backplane complete the following steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 2 Remove the air baffle see Removing the air baffle on page 188 Step 3 Remove the fan cage assembly see Removing the fan cag...

Страница 254: ...l cable routing and connectors on page 33 Step 7 If you are replacing another 2 5 inch hard disk drive backplane repeat steps 5 to 6 for installing the additional backplane Step 8 Install the fan cage assembly see Installing the fan cage assembly on page 262 Step 9 Install the air baffle see Replacing the air baffle on page 189 Step 10 Open the bezel door see Opening the bezel door on page 179 238...

Страница 255: ...e server and peripheral devices Removing the 3 5 inch hard disk drive backplane Use this information to remove the 3 5 inch hard disk drive backplane Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables...

Страница 256: ...p 5 Remove the fan cage assembly see Removing the fan cage assembly on page 261 Step 6 Note where the power signal and configuration cables are connected to the 3 5 inch hard disk drive backplane then disconnect them see Internal cable routing and connectors on page 33 Step 7 Press the release latches then rotate and release the 3 5 inch HDD backplane away from the server chassis 240 System x3500 ...

Страница 257: ...hard disk drive backplane Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a 3 5 inch hard disk drive backplane complete the following steps Step 1 Unlock and remove the left side cover s...

Страница 258: ...rd disk drive on page 202 Step 4 Remove the air baffle see Removing the air baffle on page 188 Step 5 Remove the fan cage assembly see Removing the fan cage assembly on page 261 Step 6 Insert the bottom of the 3 5 inch hard disk drive backplane onto the lower lip of the server chassis 242 System x3500 M5 Installation and Service Guide ...

Страница 259: ...89 Step 11 Install the 3 5 inch hot swap hard disk drives that were removed from the hard disk drive cage see Installing a 3 5 inch hot swap hard disk drive on page 203 Step 12 Close the bezel Step 13 Install and lock the left side cover see Installing the left side cover on page 183 If you have replaced a server component or installed an optional device in the server you need to reconnect the pow...

Страница 260: ...e parts inside these components If you suspect a problem with one of these parts contact a service technician Read the safety information in Safety on page v and Installation guidelines on page 29 Attention Static electricity that is released to internal server components when the server is powered on might cause the server to halt which might result in the loss of data To avoid this potential pro...

Страница 261: ... must consider when you install a power supply Make sure that the devices that you are installing are supported For a list of supported optional devices for the server see http www lenovo com serverproven Before you install an additional power supply or replace a power supply with one of a different wattage you may use the Power Configurator utility to determine current system power consumption Fo...

Страница 262: ... that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Read the safety information in Safety on page v and Installation guidelines on page 29 Attention Static electricity that i...

Страница 263: ...d for the new power supply into the connector on the back of the power supply then connect the other end of the power cord to a properly grounded electrical outlet Note If the server has been turned off you must wait approximately 3 minutes after you connect the server power cord to an electrical outlet before the power control button becomes active Step 6 Make sure that the ac power LED and the d...

Страница 264: ...a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To remove the operator information panel assembly complete the following steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 2 Remove the air baffle see Removing the air baffle on page 188 Step 3 Remove the f...

Страница 265: ...component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install the operator information panel assembly complete the following steps Step 1 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 2 Open the bezel see Removing the bezel on page 184 Step 3 Remove the air baffle see Removi...

Страница 266: ...r baffle on page 189 Step 13 Close the bezel see Replacing the air baffle on page 189 Step 14 Close and lock the left side cover see Installing the left side cover on page 183 If you have replaced a server component or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices Removing a memory module Use t...

Страница 267: ...ging materials for shipping that are supplied to you Memory module installation The following notes describe the types of DIMMs that the server supports and other information that you must consider when you install DIMMs When you install or remove DIMMs the server configuration information changes When you restart the server the system displays a message that indicates that the memory configuratio...

Страница 268: ...r quad rank n 4 The following rules apply to DDR4 RDIMM speed as it relates to the number of RDIMMs in a channel When you install 1 RDIMM per channel the memory runs at 2133 MHz When you install 2 RDIMMs per channel the memory runs at 1866 MHz When you install 3 RDIMMs per channel the memory runs at 1600 MHz All channels in a server run at the fastest common frequency Do not install registered and...

Страница 269: ...e Setup utility For additional information see Configuring the server on page 104 A minimum of one DIMM must be installed for each microprocessor For example you must install a minimum of two DIMMs if the server has two microprocessors installed However to improve system performance install a minimum of four DIMMs for each microprocessor DIMMs in the server must be the same type RDIMM or LRDIMM to...

Страница 270: ...cy 1600 MHz Please refer to the Understanding and Optimizing Memory Performance for Intel Xeon Processor E5 2600 v3 Series in IBM Flex System System x and BladeCenter Platforms white paper for the detail Memory mirrored channel Memory mirrored channel mode replicates and stores data on two pairs of DIMMs within two channels simultaneously If a failure occurs the memory controller switches from the...

Страница 271: ...re filled The following table shows the installation sequence for memory mirrored mode Table 37 Memory mirrored channel mode DIMM population sequence Number of DIMMs Number of installed microprocessor DIMM connector First pair of DIMMs 1 1 4 Second pair of DIMMs 1 9 12 Third pair of DIMMs 1 2 5 Fourth pair of DIMMs 1 8 11 Fifth pair of DIMMs 1 7 10 Sixth pair of DIMMs 1 3 6 First pair of DIMMs 2 1...

Страница 272: ...etup utility on page 107 The memory rank sparing mode requires an even number of DIMMs If your server has an odd number of DIMMs installed ensure that you disable the memory rank sparing mode from the Memory menu in Setup Utility See Using the Setup utility on page 107 Note After disabling the memory rank sparing mode if a message prompts that the memory configuration is not valid restart the IMM2...

Страница 273: ...ir of DIMMs 2 15 18 Note Rank Sparing is only supported when there is more than 1DPC or if a single QRDIMM is installed Installing a DIMM Use this information to install a DIMM Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power co...

Страница 274: ...IMM to any unpainted metal surface on the outside of the server Then remove the DIMM from the package Step 7 Turn the DIMM so that the alignment slot align correctly with the alignment tab Step 8 Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector see System board internal connectors on page 25 for the locations of the DIMM connecto...

Страница 275: ...nent or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices Removing a USB embedded hypervisor flash device Use this information to remove a USB embedded hypervisor flash device Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server compon...

Страница 276: ...vice Use this information to install a USB embedded hypervisor flash device Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install a hypervisor flash device complete the following steps Step 1 ...

Страница 277: ... Installing the left side cover on page 183 If you have replaced a server component or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices Removing the fan cage assembly Use this information to remove the fan cage assembly from the server Read the safety information in Safety on page v and Installati...

Страница 278: ...packaging instructions and use any packaging materials for shipping that are supplied to you Installing the fan cage assembly Use this information to install the fan cage assembly from the server Attention Make sure that all wires and cables inside the server are routed correctly before you install the fan cage assembly Wiring that is not properly routed might be damaged or might prevent the fan c...

Страница 279: ...mbly Figure 181 Fan cage installation Step 7 Connect the fan cage assembly power cable to the system board see Internal cable routing and connectors on page 33 Step 8 Install the air baffle see Replacing the air baffle on page 189 Step 9 Install and lock the left side cover see Installing the left side cover on page 183 If you have replaced a server component or installed an optional device in the...

Страница 280: ...er cut off switch assembly Use this information to install the left side cover power cut off switch assembly Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disconnect the power cords and all external cables To install the left side cover power cut...

Страница 281: ...he type of warranty service that is designated for your server The illustrations in this document might differ slightly from your hardware Removing the power paddle card Use this information to remove the power paddle card Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and ...

Страница 282: ... 9 Grasp on the plunger of paddle card cage assembly and pull it toward the front of the server firstly then lift it out of the server 0 0 00 00 0 0 0 0 0 00 00 1 2 Power paddle card cover Plunger Figure 184 Power paddle card cage assembly removal Step 10 Disconnect the cables from the power paddle card see Internal cable routing and connectors on page 33 Step 11 Loosen the 4 screws to release the...

Страница 283: ...ease the redundant power paddle card If you are instructed to return the server component or optional device follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing the power paddle card Use this information to install the power paddle card Read the safety information in Safety on page v and Installation guidelines on page 29 Chapter 6 Rem...

Страница 284: ...rd and disconnect the cables from the power paddle card after removing the cover see Internal cable routing and connectors on page 33 Step 7 Remove the power supplies see Removing a hot swap power supply on page 243 Step 8 Remove the system board see Removing the system board on page 288 Step 9 Grasp on the plunger of paddle card cage assembly and pull it toward the front of the server firstly the...

Страница 285: ...le card 00 00 Power paddle card redundant Figure 189 The redundant power paddle card installation Step 14 Reconnect the cables to the power paddle card see Internal cable routing and connectors on page 33 Step 15 Pull up the plunger of the power paddle card cover and gently put it down Then push it backward to the rear of the chassis until it clicks into place Chapter 6 Removing and replacing comp...

Страница 286: ... the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices Removing a microprocessor and heat sink Use this information to remove a microprocessor and heat sink Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and p...

Страница 287: ...e of microprocessor and supports the following families of microprocessors E5 26xx E5 46xx Installation Tool B has two settings for installing two different sizes of microprocessors The settings that are marked on Tool B are L for smaller low core microprocessors and H for larger high core microprocessors Installation Tool B supports the following families of microprocessors E5 26xx E5 46xx E5 26x...

Страница 288: ...eapply clean thermal grease to the heat sink a Rotate the heat sink release lever to the fully open position Heat sink Heat sink release lever Figure 192 Rotate the heat sink release lever to the open position b Remove the heat sink out of the server After removal place the heat sink with the thermal grease side up on a clean flat surface Heat sink Heat sink release lever Lock tab Figure 193 Remov...

Страница 289: ... contacts and the socket Step 6 Install the microprocessor on the microprocessor installation tool Note If you are replacing a microprocessor use the empty installation tool that comes with the new microprocessor to remove the microprocessor a Select the empty installation tool and ensure that the handle is in the open position If the installation tool handle is not in the open position use the fo...

Страница 290: ... latch The following illustration of the installation tool shows the location of the interlock latch and counterclockwise rotation of the handle before loading the microprocessor H Figure 196 Installation tool B handle adjustment b Align the installation tool with the alignment pins on the microprocessor socket and carefully lower down the tool on the microprocessor The installation tool rests on ...

Страница 291: ...gn the installation tool c Twist the handle on the installation tool clockwise Installation tool Microprocessor Handle Figure 198 Twist the handle clockwise d Lift the microprocessor out of the socket Chapter 6 Removing and replacing components 275 ...

Страница 292: ... use the microprocessor installation tool may damage the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board The server supports certain Intel Xeon scalable multi core microprocessors which are designed for the LGA 2011 socket These microprocessors are 64 bit dual core or quad core microprocessors with an integrated memory cont...

Страница 293: ...e heat sink do not touch the thermal grease on the bottom of the heat sink or set down the heat sink For more information about applying or working with thermal grease see Thermal grease on page 92 Note Removing the heat sink from the microprocessor destroys the even distribution of the thermal grease and requires replacing the thermal grease Do not remove the first microprocessor from the system ...

Страница 294: ...pheral devices and disconnect the power cords and all external cables To install a microprocessor and heat sink complete the following steps Step 1 Carefully turn the server on its side so that it is lying flat with the cover facing up Attention Do not allow the server to fall over Step 2 Unlock and remove the left side cover see Removing the left side cover on page 182 Step 3 Remove the air baffl...

Страница 295: ... Open the second release lever on the microprocessor socket c Open the microprocessor retainer Attention Do not touch the connectors on the microprocessor and the microprocessor socket Step 6 Install the microprocessor on the microprocessor socket a Touch the static protective package that contains the new microprocessor to any unpainted on the chassis or any unpainted metal surface on any other g...

Страница 296: ... and the socket c Align the installation tool with the microprocessor socket The installation tool rests flush on the socket only if properly aligned Installation tool Microprocessor Alignment pins Figure 204 Align the installation tool with the microprocessor socket d Install the microprocessor using the following instructions for your installation tool If using Installation Tool A twist the hand...

Страница 297: ...justment Attention Do not press the microprocessor into the socket Make sure that the microprocessor is oriented and aligned correctly in the socket before you try to close the microprocessor retainer Do not touch the thermal material on the bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it Step 7 Remove the microprocessor socket dust cover t...

Страница 298: ... Close the microprocessor socket release levers and retainer a Close the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket 1 3 2 Microprocessor release lever Microprocessor release lever Figure 208 Close the release lever Step 9 Install the hea...

Страница 299: ...rotective cover from the bottom of the heat sink 2 Position the heat sink over the microprocessor The heat sink is keyed to assist with proper alignment 3 Align the heat sink to the retainer bracket tabs and place the heat sink on top of the microprocessor thermal material side down Heat sink Lock tab Retainer bracket tabs Heat sink release lever Figure 210 Install the heat sink 4 Press firmly on ...

Страница 300: ...mal grease on the microprocessor and heat sink When you are installing the heat sink on the same microprocessor that it was removed from make sure that the following requirements are met The thermal grease on the heat sink and microprocessor is not contaminated Additional thermal grease is not added to the existing thermal grease on the heat sink and microprocessor Notes Read the safety informatio...

Страница 301: ...stall the heat sink onto the microprocessor as described in Installing a microprocessor and heat sink on page 276 Removing a heat sink Use this information to remove a heat sink retention module Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to turn off the server and peripheral devices and disco...

Страница 302: ...ructed to return the server component or optional device follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing a heat sink Use this information to install a heat sink retention module Read the safety information in Safety on page v and Installation guidelines on page 29 If you are replacing a server component in the server you need to tu...

Страница 303: ...heat sink over the microprocessor The heat sink is keyed to assist with proper alignment Step 5 Align the heat sink to the retainer bracket tabs and place the heat sink on top of the microprocessor thermal material side down Heat sink Lock tab Retainer bracket tabs Heat sink release lever Figure 216 Install the heat sink Attention Make sure that you install each heat sink with its paired microproc...

Страница 304: ...mand User s Guide To download the document go to https fod lenovo com lkms log in and click Help 2 When you replace the system board you must either update the server with the latest firmware or restore the pre existing firmware that the customer provides on a diskette or CD image Make sure that you have the latest firmware or a copy of the pre existing firmware before you proceed 3 When you repla...

Страница 305: ...ving the cables will damage the cable sockets on the system board The cable sockets on the system board are fragile Any damage to the cable sockets may require replacing the system board Step 6 Remove any of the following components that are installed on the system board and put them in a safe static protective place Adapters see Removing an adapter on page 215 DIMMs see Removing a memory module o...

Страница 306: ... 8 Slide the system board toward the front of the server then grasp the thumbs screws as the handles to carefully lift the system board out of the server 0 0 00 00 0 0 0 0 0 00 00 1 2 System board Figure 219 System board removal 290 System x3500 M5 Installation and Service Guide ...

Страница 307: ...UID on page 119 and Updating the DMI SMBIOS data on page 121 3 When you replace the system board make sure that you remove the Integrated Management Module II IMM2 Advanced Upgrade and place it on the new system board For information about the Advanced Upgrade see Using the remote presence and blue screen capture features on page 113 4 Reactivate any Features on Demand features after replacing the...

Страница 308: ...ns Guide pins Figure 220 Align guide pins and alignment pins on the server chassis Step 3 Gently insert the system board and slide the system board toward the rear of the server 292 System x3500 M5 Installation and Service Guide ...

Страница 309: ... Hypervisor see Installing a USB embedded hypervisor flash device on page 260 Step 6 Reconnect any cables to the system board that you disconnected during removal see System board internal connectors on page 25 and Internal cable routing and connectors on page 33 Step 7 Install the fan cage assembly see Installing the fan cage assembly on page 262 Step 8 Install the air baffle see Replacing the ai...

Страница 310: ...ate the UUID see Updating the Universal Unique Identifier UUID on page 119 Step 14 Update the DMI SMBIOS see Updating the DMI SMBIOS data on page 121 Step 15 Reactivate any Features on Demand features If you have replaced a server component or installed an optional device in the server you need to reconnect the power cords and all external cables and turn on the server and peripheral devices 294 S...

Страница 311: ...he condition In the system event log severity is abbreviated to the first character The following severities can be displayed Info The event was recorded for audit purposes usually a user action or a change of states that is normal behavior Warning The event is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that r...

Страница 312: ...ify Support You can configure the Integrated Management Module II IMM2 to automatically notify Support also known as call home if certain types of errors are encountered If you have configured this function see the table for a list of events that automatically notify Support Table 39 Events that automatically notify Support Event ID Message String Automatically Notify Support 40000086 00000000 Tes...

Страница 313: ... 806f010c 2009xxxx Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 Yes 806f010c 200axxxx Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 Yes 806f010c 200bxxxx Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 Yes 806f010c 200cxxxx Uncorrectable error de...

Страница 314: ...ementName All DIMMS Yes 806f010d 0400xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 0 Yes 806f010d 0401xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 1 Yes 806f010d 0402xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 2 Yes 806f010d 0403xxxx The Drive StorageVolumeElementName ha...

Страница 315: ...detected fault Drive 20 Yes 806f010d 0415xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 21 Yes 806f010d 0416xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 22 Yes 806f010d 0417xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 23 Yes 806f010d 0418xxxx The Drive StorageVolumeElement...

Страница 316: ...ure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 8 Yes 806f020d 0409xxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 9 Yes 806f020d 040axxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 10 Yes 806f020d 040bxxxx Failure Predicted on drive StorageVolumeElementNa...

Страница 317: ...lumeElementName for array ComputerSystemElementName Drive 28 Yes 806f020d 041dxxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 29 Yes 806f020d 041exxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 30 Yes 806f020d 041fxxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEle...

Страница 318: ...IMM 14 Yes 806f050c 200fxxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 Yes 806f050c 2010xxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 Yes 806f050c 2011xxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 Yes 806f050c 2012xxxx Memory Logg...

Страница 319: ...xx Array ComputerSystemElementName has failed Drive 6 Yes 806f060d 0407xxxx Array ComputerSystemElementName has failed Drive 7 Yes 806f060d 0408xxxx Array ComputerSystemElementName has failed Drive 8 Yes 806f060d 0409xxxx Array ComputerSystemElementName has failed Drive 9 Yes 806f060d 040axxxx Array ComputerSystemElementName has failed Drive 10 Yes 806f060d 040bxxxx Array ComputerSystemElementName...

Страница 320: ...060d 041cxxxx Array ComputerSystemElementName has failed Drive 28 Yes 806f060d 041dxxxx Array ComputerSystemElementName has failed Drive 29 Yes 806f060d 041exxxx Array ComputerSystemElementName has failed Drive 30 Yes 806f060d 041fxxxx Array ComputerSystemElementName has failed Drive 31 Yes 806f0813 2581xxxx An Uncorrectable Bus Error has occurred on system ComputerSystemElementName DIMMs Yes 806f...

Страница 321: ...s 4000000200000000 or 0x4000000200000000 Severity Error Serviceable No Automatically notify support No Alert Category System SSL certification SNMP Trap ID 22 CIM Information Prefix IMM ID 0002 User Response Make sure that the certificate that you are importing is correct and properly generated 40000003 00000000 Ethernet Data Rate modified from arg1 to arg2 by user arg3 This message is for the use...

Страница 322: ...00400000000 or 0x4000000400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0004 User Response Information only no action is required 40000005 00000000 Ethernet MTU setting modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the Ethernet Port MTU setting May also be shown as...

Страница 323: ...r 0x4000000600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0006 User Response Information only no action is required 40000007 00000000 Ethernet interface arg1 by user arg2 This message is for the use case where a user enables or disabled the ethernet interface May also be shown as 4000000700000000 or 0x4000000700...

Страница 324: ...rt No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0008 User Response Information only no action is required 40000009 00000000 IP address of network interface modified from arg1 to arg2 by user arg3 This message is for the use case where user modifies the IP address of a Management Controller May also be shown as 4000000900000000 or 0x4000000900000000 Sever...

Страница 325: ...cally notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0010 User Response Information only no action is required 4000000b 00000000 IP address of default gateway modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the default gateway IP address of a Management Controller May also be shown as 4000000b00000000 or 0x4000000b000...

Страница 326: ...t No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0012 User Response Information only no action is required 4000000d 00000000 DHCP arg1 failure no IP address assigned This message is for the use case where a DHCP server fails to assign an IP address to a Management Controller May also be shown as 4000000d00000000 or 0x4000000d00000000 Severity Warning Serviceable No Automatically...

Страница 327: ...0x4000000e00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0014 User Response Information only no action is required 4000000f 00000000 Attempting to arg1 server arg2 by user arg3 This message is for the use case where a user is using the Management Controller to perform a power function on the sys...

Страница 328: ...rap ID 30 CIM Information Prefix IMM ID 0016 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 40000011 00000000 Security Login ID arg1 had arg2 login failures from CLI at arg3 This message is for the use case where a user has failed to log in to a M...

Страница 329: ... also be shown as 4000001200000000 or 0x4000001200000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0018 User Response Make sure that the correct login ID and password are being used 40000013 00000000 Remote access attempt failed Invalid userid or password received Userid is arg1 from TELNET client a...

Страница 330: ...00001400000000 or 0x4000001400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0020 User Response Information only no action is required 40000015 00000000 Management Controller arg1 reset was initiated by user arg2 This message is for the use case where a Management Controller reset is initiated by a user May also be...

Страница 331: ...00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0022 User Response Information only no action is required 40000017 00000000 ENET arg1 IP Cfg HstName arg2 IP arg3 NetMsk arg4 GW arg5 This message is for the use case where a Management Controller IP address and configuration has been assigned statically using user d...

Страница 332: ...00001800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0024 User Response Information only no action is required 40000019 00000000 LAN Ethernet arg1 interface is now active This message is for the use case where a Management Controller ethernet interface is now active May also be shown as 4000001900000000 or 0x4000...

Страница 333: ...otify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0026 User Response Information only no action is required 4000001b 00000000 Management Controller arg1 Configuration restored from a file by user arg2 This message is for the use case where a user restores a Management Controller configuration from a file May also be shown as 4000001b00000000 or 0x4000001b00000000 Seve...

Страница 334: ... no operating system error complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog If there was an operating system error check the integrity of the installed operating system 4000001d 00...

Страница 335: ...e latest level of code is supported for the cluster solution before you update the code 4000001e 00000000 Running the backup Management Controller arg1 main application This message is for the use case where a Management Controller has resorted to running the backup main application May also be shown as 4000001e00000000 or 0x4000001e00000000 Severity Warning Serviceable No Automatically notify sup...

Страница 336: ...at the server supports Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 40000020 00000000 Management Controller arg1 Reset was caused by restoring default values This message is for the use case where a Management...

Страница 337: ...formation only no action is required 40000022 00000000 SSL data in the Management Controller arg1 configuruation data is invalid Clearing configuration data region and disabling SSL This message is for the use case where a Management Controller has detected invalid SSL data in the configuration data and is clearing the configuration data region and disabling the SSL May also be shown as 4000002200...

Страница 338: ...re Processor from the interface and IP address d May also be shown as 4000002300000000 or 0x4000002300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0035 User Response Information only no action is required 40000024 00000000 Flash of arg1 from arg2 failed for user arg3 This message is for the use case where a user ...

Страница 339: ...ategory System Event Log 75 full SNMP Trap ID 35 CIM Information Prefix IMM ID 0037 User Response Information only no action is required 40000026 00000000 The arg1 on system arg2 is 100 full This message is for the use case where a Management Controller Event Log on a system is 100 full May also be shown as 4000002600000000 or 0x4000002600000000 Severity Info Serviceable No Automatically notify su...

Страница 340: ...ponse Complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog 5 Check the integrity of the installed operating system 40000028 00000000 Management Controller Test Alert Generated by arg1 ...

Страница 341: ...Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0041 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 4000002a 00000000 arg1 firmware mismatch internal to system arg2 Please attempt to flash the arg3 firmware This message is for the use c...

Страница 342: ...0 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0043 User Response Information only no action is required 4000002c 00000000 Domain Source changed to arg1 by user arg2 Domain source changed by user May also be shown as 4000002c00000000 or 0x4000002c00000000 Severity Info Serviceable No Automatically notify support No Aler...

Страница 343: ... No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0045 User Response Information only no action is required 4000002e 00000000 DDNS registration successful The domain name is arg1 DDNS registration and values May also be shown as 4000002e00000000 or 0x4000002e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SN...

Страница 344: ...cally notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0047 User Response Information only no action is required 40000030 00000000 IPv6 disabled by user arg1 IPv6 protocol is disabled by user May also be shown as 4000003000000000 or 0x4000003000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix...

Страница 345: ...ry none SNMP Trap ID CIM Information Prefix IMM ID 0049 User Response Information only no action is required 40000032 00000000 IPv6 DHCP enabled by user arg1 IPv6 DHCP assignment method is enabled by user May also be shown as 4000003200000000 or 0x4000003200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0050 User R...

Страница 346: ...51 User Response Information only no action is required 40000034 00000000 IPv6 static IP configuration disabled by user arg1 IPv6 static assignment method is disabled by user May also be shown as 4000003400000000 or 0x4000003400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0052 User Response Information only no ac...

Страница 347: ...ed by user arg1 IPv6 statless auto assignment method is disabled by user May also be shown as 4000003600000000 or 0x4000003600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0054 User Response Information only no action is required 40000037 00000000 ENET arg1 IPv6 LinkLocal HstName arg2 IP arg3 Pref arg4 IPv6 Link L...

Страница 348: ...dress is active May also be shown as 4000003800000000 or 0x4000003800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0056 User Response Information only no action is required 40000039 00000000 ENET arg1 DHCPv6 HSTN arg2 DN arg3 IP arg4 Pref arg5 IPv6 DHCP assigned address is active May also be shown as 4000003900000...

Страница 349: ...gement Controller May also be shown as 4000003a00000000 or 0x4000003a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0058 User Response Information only no action is required 4000003b 00000000 DHCPv6 failure no IP address assigned S DHCP6 server fails to assign an IP address to a Management Controller May also be ...

Страница 350: ...Watchdog Timer Expired May also be shown as 4000003c00000000 or 0x4000003c00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Loader timeout SNMP Trap ID 26 CIM Information Prefix IMM ID 0060 User Response 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether dev...

Страница 351: ... by user arg3 A user has modified the SSH port number May also be shown as 4000003e00000000 or 0x4000003e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0062 User Response Information only no action is required 4000003f 00000000 Web HTTP port number changed from arg1 to arg2 by user arg3 A user has modified the We...

Страница 352: ...rt number May also be shown as 4000004000000000 or 0x4000004000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0064 User Response Information only no action is required 40000041 00000000 CIM XML HTTP port number changed from arg1 to arg2 by user arg3 A user has modified the CIM HTTP port number May also be shown as ...

Страница 353: ...be shown as 4000004200000000 or 0x4000004200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0066 User Response Information only no action is required 40000043 00000000 SNMP Agent port number changed from arg1 to arg2 by user arg3 A user has modified the SNMP Agent port number May also be shown as 4000004300000000 or...

Страница 354: ...4400000000 or 0x4000004400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0068 User Response Information only no action is required 40000045 00000000 Syslog port number changed from arg1 to arg2 by user arg3 A user has modified the Syslog receiver port number May also be shown as 4000004500000000 or 0x40000045000000...

Страница 355: ...r 0x4000004600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0070 User Response Information only no action is required 40000047 00000000 LED arg1 state changed to arg2 by arg3 A user has modified the state of an LED May also be shown as 4000004700000000 or 0x4000004700000000 Severity Info Serviceable No Automatical...

Страница 356: ...04800000000 or 0x4000004800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0072 User Response Information only no action is required 40000049 00000000 SNMP arg1 enabled by user arg2 A user enabled SNMPv1 or SNMPv3 or Traps May also be shown as 4000004900000000 or 0x4000004900000000 Severity Info Serviceable No Autom...

Страница 357: ...cally notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0074 User Response Information only no action is required 4000004b 00000000 SNMPv1 arg1 set by user arg2 Name arg3 AccessType arg4 Address arg5 A user changed the SNMP community string May also be shown as 4000004b00000000 or 0x4000004b00000000 Severity Info Serviceable No Automatically notify support No Alert C...

Страница 358: ...cally notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0076 User Response Information only no action is required 4000004d 00000000 LDAP set by user arg1 RootDN arg2 UIDSearchAttribute arg3 BindingMethod arg4 EnhancedRBS arg5 TargetName arg6 GroupFilter arg7 GroupAttribute arg8 LoginAttribute arg9 A user configured an LDAP Miscellaneous setting May also be shown as 4...

Страница 359: ...ble No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0078 User Response Information only no action is required 4000004f 00000000 Date and Time set by user arg1 Date arg2 Time arg3 DST Auto adjust arg4 Timezone arg5 A user configured the Date and Time settings May also be shown as 4000004f00000000 or 0x4000004f00000000 Severity Info Serviceable No Au...

Страница 360: ...nfo Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0080 User Response Information only no action is required 40000051 00000000 Server Power Off Delay set to arg1 by user arg2 A user configured the Server Power Off Delay May also be shown as 4000005100000000 or 0x4000005100000000 Severity Info Serviceable No Automatically notify support...

Страница 361: ...Trap ID CIM Information Prefix IMM ID 0082 User Response Information only no action is required 40000053 00000000 Server arg1 scheduled for every arg2 at arg3 by user arg4 A user configured a recurring Server Power Action May also be shown as 4000005300000000 or 0x4000005300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix I...

Страница 362: ...quired 40000055 00000000 Synchronize time setting by user arg1 Mode arg2 NTPServerHost arg3 arg4 NTPUpdateFrequency arg5 A user configured the Date and Time synchronize settings May also be shown as 4000005500000000 or 0x4000005500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0085 User Response Information only no...

Страница 363: ...et services May also be shown as 4000005700000000 or 0x4000005700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0087 User Response Information only no action is required 40000058 00000000 DNS servers set by user arg1 UseAdditionalServers arg2 PreferredDNStype arg3 IPv4Server1 arg4 IPv4Server2 arg5 IPv4Server3 arg6 ...

Страница 364: ...red USB LAN May also be shown as 4000005900000000 or 0x4000005900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0089 User Response Information only no action is required 4000005a 00000000 LAN over USB Port Forwarding set by user arg1 ExternalPort arg2 USB LAN port arg3 A user configured USB LAN port forwarding May ...

Страница 365: ...ces May also be shown as 4000005b00000000 or 0x4000005b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0091 User Response Information only no action is required 4000005c 00000000 Secure CIM XML HTTPS arg1 by user arg2 A user enables or disables Secure CIM XML services May also be shown as 4000005c00000000 or 0x400...

Страница 366: ...vices May also be shown as 4000005d00000000 or 0x4000005d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0093 User Response Information only no action is required 4000005e 00000000 SSH arg1 by user arg2 A user enables or disables SSH services May also be shown as 4000005e00000000 or 0x4000005e00000000 Severity Inf...

Страница 367: ...figures Server Timeouts May also be shown as 4000005f00000000 or 0x4000005f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0095 User Response Information only no action is required 40000060 00000000 License key for arg1 added by user arg2 A user installs License Key May also be shown as 4000006000000000 or 0x40000...

Страница 368: ... Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0097 User Response Information only no action is required 40000062 00000000 Global Login General Settings set by user arg1 AuthenticationMethod arg2 LockoutPeriod arg3 SessionTimeout arg4 A user changes the Global Login General Settings May also be shown as 4000006200000000 or 0x400000620...

Страница 369: ...erentCharacters arg9 DefaultIDExpired arg10 ChangePasswordFirstAccess arg11 A user changes the Global Login Account Security Settings to Legacy May also be shown as 4000006300000000 or 0x4000006300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0099 User Response Information only no action is required 40000064 00000...

Страница 370: ...000000 or 0x4000006500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0101 User Response Information only no action is required 40000066 00000000 User arg1 password modified A user account was changed May also be shown as 4000006600000000 or 0x4000006600000000 Severity Info Serviceable No Automatically notify suppor...

Страница 371: ...ty Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0103 User Response Information only no action is required 40000068 00000000 User arg1 custom privileges set arg2 User account privileges assigned May also be shown as 4000006800000000 or 0x4000006800000000 Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 372: ...6900000000 or 0x4000006900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0105 User Response Information only no action is required 4000006a 00000000 SSH Client key added for user arg1 User locally defined an SSH Client key May also be shown as 4000006a00000000 or 0x4000006a00000000 Severity Info Serviceable No Auto...

Страница 373: ...Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0107 User Response Information only no action is required 4000006c 00000000 SSH Client key removed from user arg1 User removed an SSH Client key May also be shown as 4000006c00000000 or 0x4000006c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP...

Страница 374: ...t No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0109 User Response Information only no action is required 4000006e 00000000 Alert Configuration Global Event Notification set by user arg1 RetryLimit arg2 RetryInterval arg3 EntryInterval arg4 A user changes the Global Event Notification settings May also be shown as 4000006e00000000 or 0x4000006e00000000 Severity Info Serviceable...

Страница 375: ...tomatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0111 User Response Information only no action is required 40000070 00000000 SNMP Traps enabled by user arg1 EnabledAlerts arg2 AllowedFilters arg3 A user enabled the SNMP Traps configuration May also be shown as 4000007000000000 or 0x4000007000000000 Severity Info Serviceable No Automatically notify suppor...

Страница 376: ...P Trap ID CIM Information Prefix IMM ID 0113 User Response Information only no action is required 40000072 00000000 The minimum power cap value changed from arg1 watts to arg2 watts Minimum Power Cap value changed May also be shown as 4000007200000000 or 0x4000007200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 01...

Страница 377: ...only no action is required 40000074 00000000 The soft minimum power cap value changed from arg1 watts to arg2 watts Soft Minimum Power Cap value changed May also be shown as 4000007400000000 or 0x4000007400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0116 User Response Information only no action is required 40000...

Страница 378: ...e exceeded the power cap value Minimum Power Cap exceeds Power Cap May also be shown as 4000007600000000 or 0x4000007600000000 Severity Warning Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0118 User Response Information only no action is required 40000077 00000000 Power capping was activated by user arg1 Power capping ac...

Страница 379: ...be shown as 4000007800000000 or 0x4000007800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0120 User Response Information only no action is required 40000079 00000000 Static Power Savings mode has been turned on by user arg1 Static Power Savings mode turned on by user May also be shown as 4000007900000000 or 0x4000...

Страница 380: ...y also be shown as 4000007a00000000 or 0x4000007a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0122 User Response Information only no action is required 4000007b 00000000 Dynamic Power Savings mode has been turned on by user arg1 Dynamic Power Savings mode turned on by user May also be shown as 4000007b00000000 ...

Страница 381: ...0007c00000000 or 0x4000007c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0124 User Response Information only no action is required 4000007d 00000000 Power cap and external throttling occurred Power cap and external throttling occurred May also be shown as 4000007d00000000 or 0x4000007d00000000 Severity Info Serv...

Страница 382: ...0000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0126 User Response Information only no action is required 4000007f 00000000 Power cap throttling occurred Power cap throttling occurred May also be shown as 4000007f00000000 or 0x4000007f00000000 Severity Info Serviceable No Automatically notify support No Alert Categ...

Страница 383: ... Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0128 User Response Information only no action is required 40000081 00000000 PXE boot requested by user arg1 PXE boot requested May also be shown as 4000008100000000 or 0x4000008100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Tr...

Страница 384: ...notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0130 User Response Information only no action is required 40000083 00000000 The new minimum power cap value has returned below the power cap value Minimum Power Cap exceeds Power Cap recovered May also be shown as 4000008300000000 or 0x4000008300000000 Severity Info Serviceable No Automatically notify sup...

Страница 385: ... Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0132 User Response Attempt to flash the IMM firmware to the same level on all nodes 40000085 00000000 FPGA firmware mismatch between nodes arg1 and arg2 Please attempt to flash the FPGA firmware to the same level on all nodes A mismatch of FPGA firmware has been detected between nodes May also be shown as 4000008500000000 o...

Страница 386: ...matically notify support Yes Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0134 User Response Information only no action is required 40000087 00000000 Manual Call Home by user arg1 arg2 Manual Call Home by user May also be shown as 4000008700000000 or 0x4000008700000000 Severity Info Serviceable No Automatically notify support Yes Alert Category none SNMP Trap ID CIM Information P...

Страница 387: ...p ID CIM Information Prefix IMM ID 0136 User Response Information only no action is required 40000089 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 failed to complete This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to complete May also be shown as 4000008900000000 or 0x400000...

Страница 388: ...0000000 or 0x4000008a00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0138 User Response 1 Turn off the server and disconnect it from the power source You must disconnect the server from ac power to reset the IMM 2 After 45 seconds reconnect the server to the power source and turn on the server 3 Retry ...

Страница 389: ... be shown as 800100020701xxxx or 0x800100020701xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Voltage SNMP Trap ID 13 CIM Information Prefix PLAT ID 0476 User Response Replace the system battery 80010202 0701xxxx Numeric sensor NumericSensorElementName going low lower critical has asserted CMOS Battery This message is for the use case when an implement...

Страница 390: ...chnician only Replace the system board n power supply number SysBrd 12V SysBrd 3 3V SysBrd 5V 80010204 1d01xxxx Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 1 Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d01xxxx or 0x800102041d01xxxx Severity Error Servicea...

Страница 391: ... User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d03xxxx Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 3 Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as ...

Страница 392: ...r Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010701 1401xxxx Numeric sensor NumericSensorElementName going high upper non critical has asserted CPU1 V...

Страница 393: ...lementName going high upper non critical has asserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011402xxxx or 0x800107011402xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490...

Страница 394: ... there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician...

Страница 395: ...mentName going high upper non critical has asserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011405xxxx or 0x800107011405xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 049...

Страница 396: ...that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained techni...

Страница 397: ...lementName going high upper non critical has asserted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107013701xxxx or 0x800107013701xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490...

Страница 398: ... there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician...

Страница 399: ...orElementName going high upper critical has asserted DIMM AB VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011403xxxx or 0x800109011403xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 Use...

Страница 400: ... there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician...

Страница 401: ...orElementName going high upper critical has asserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011406xxxx or 0x800109011406xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 Use...

Страница 402: ...here are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician o...

Страница 403: ...or NumericSensorElementName going high upper critical has asserted SysBrd 12V This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109020701xxxx or 0x800109020701xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 04...

Страница 404: ...hat the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 1402xxxx Numeric sensor NumericSenso...

Страница 405: ... message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011403xxxx or 0x80010b011403xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that there are ...

Страница 406: ...hat the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 1405xxxx Numeric sensor NumericSenso...

Страница 407: ... message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011406xxxx or 0x80010b011406xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that there are ...

Страница 408: ...t the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 3701xxxx Numeric sensor NumericSensorE...

Страница 409: ...y Replace system board 80030006 2101xxxx Sensor SensorElementName has deasserted Sig Verify Fail This message is for the use case when an implementation has detected a Sensor has deasserted May also be shown as 800300062101xxxx or 0x800300062101xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Respons...

Страница 410: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response 1 Replace the power supply with higher rated power 2 Reduce the total power consumption by removing newly added or unused option like drives or adapters 8003010c 2581xxxx Sensor SensorElementName has asserted Non Auth DIMMs This message is for the...

Страница 411: ...n has detected a Sensor has asserted May also be shown as 8003010f2101xxxx or 0x8003010f2101xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response 1 Replace the power supply with higher rated power 2 Reduce the total power consumption by removing newly added or unused option like drives or adapter...

Страница 412: ...option like drives or adapters SMM Monitor 8007000d 2582xxxx Sensor SensorElementName has transitioned to normal state RAID Vol State This message is for the use case when an implementation has detected a Sensor transition to the normal state May also be shown as 8007000d2582xxxx or 0x8007000d2582xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Tr...

Страница 413: ...r SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response None 8007010f 2201xxxx Sensor SensorElementName has transitioned from normal to non critical state GPT Status This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010f2201xxxx or 0x8007010f2201xxxx Severity Warning Serviceable Yes Automatica...

Страница 414: ...ceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response 1 Check the Lenovo support site for service bulletins or firmware updates that apply to this GPT error 2 Set the UEFI setting DISK GPT Recovery to Automatic 3 Replace the corrupt disk 80070114 2201xxxx Sensor SensorElementName has transitioned from normal to non...

Страница 415: ...ssage is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 800701282e01xxxx or 0x800701282e01xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response None 80070201 0301xxxx Sensor SensorElementName has transitioned to ...

Страница 416: ...d specifications for more information 3 Make sure that the heat sink for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 80070201 0302xxxx Sensor SensorElementName has transitioned to critical from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected a Sensor transitioned to critic...

Страница 417: ...2020701xxxx or 0x800702020701xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0522 User Response 1 Check the system event log 2 Check for an error LED on the system board 3 Replace any failing device 4 Check for a server firmware update Important Some cluster solutions require specific code levels or c...

Страница 418: ...l from a less severe state PS 2 Fan Fault This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702040a02xxxx or 0x800702040a02xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure t...

Страница 419: ...r supply fan 2 Use the Lenovo Power Configurator utility to ensure current system power consumption is under limitation For more information and to download the utility go to https www ibm com support entry myportal docdisplay lndocid LNVO PWRCONF 3 Replace power supply n n power supply number 80070208 0a02xxxx Sensor SensorElementName has transitioned to critical from a less severe state PS 2 The...

Страница 420: ... a less severe state RAID Vol State This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 8007020d2582xxxx or 0x8007020d2582xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response None 8007020f 2201xxxx Se...

Страница 421: ...s severe state I O Resources This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 8007020f2582xxxx or 0x8007020f2582xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response 1 If enabling TXT is not require...

Страница 422: ...irmware see Recovering the server firmware 2 If the problem persists trained technician only replace the system board see Removing the system board and Installing the system board 80070219 0701xxxx Sensor SensorElementName has transitioned to critical from a less severe state SysBrd Fault This message is for the use case when an implementation has detected a Sensor transitioned to critical from le...

Страница 423: ...detected a Sensor transitioned to critical from less severe May also be shown as 8007021b0301xxxx or 0x8007021b0301xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response 1 Check for a server firmware update 2 Make sure that the installed microprocessors are compatible 3 Make sure the microp...

Страница 424: ...ssor 2 expansion board 4 Trained technician only Replace microprocessor 5 Trained technician only Replace microprocessor 2 expansion board 80070228 2e01xxxx Sensor SensorElementName has transitioned to critical from a less severe state ME Error This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702282e01xx...

Страница 425: ...ar of the server that the air baffle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number...

Страница 426: ...he heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 8007030d 2582xxxx Sensor SensorElementName has transitioned to non recoverable from a less severe state RAID Vol State This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from less severe May also be shown as 8007030d2582xxxx or 0x80...

Страница 427: ... is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12V UV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Follow actions in Power Problems and Solving Power Problems 4 Trained technician only Repl...

Страница 428: ...chnician only Replace the system board n power supply number If the specified sensor is PS n 12V UV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Follow actions in Power Problems and Solving Power Problems 4 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12Vaux Fa...

Страница 429: ...This message is for the use case when an implementation has detected a Device was removed May also be shown as 800800171001xxxx or 0x800800171001xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0537 User Response No action information only 80080017 1002xxxx Device LogicalDeviceElementName has been removed from...

Страница 430: ...tected a Device was removed May also be shown as 800800171003xxxx or 0x800800171003xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0537 User Response No action information only 8008010f 2101xxxx Device LogicalDeviceElementName has been added Phy Presence Jmp This message is for the use case when an implementa...

Страница 431: ...wn as 800801282101xxxx or 0x800801282101xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0536 User Response No action information only 800b0008 1301xxxx Redundancy RedundancySetElementName has been restored Power Unit This message is for the use case when an implementation has detected Redundancy was Restored ...

Страница 432: ...xx or 0x800b01081301xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0802 User Response 1 Check the LEDs for both power supplies 2 Follow the actions in Power supply LEDs 800b010a 1e81xxxx Redundancy Lost for RedundancySetElementName has asserted Fan Zone 1 This message is for the use ca...

Страница 433: ...00b010c 2581xxxx Redundancy Lost for RedundancySetElementName has asserted Backup Memory This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010c2581xxxx or 0x800b010c2581xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0802 User Response 1 Check the system event...

Страница 434: ...nt sufficient Power load will be handled by remaining power supply though the system may throttle to avoid a power supply over current condition 2 Replace the power supply with higher rated power 800b030c 2581xxxx Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has asserted Backup Memory This message is for the use case when a Redundancy ...

Страница 435: ...he system will attempt to throttle to avoid a power supply over current condition But a system shutdown may happen anyway if the power load is too great 2 Reduce the total power consumption by removing newly added or unused options like drives or adaptors 3 Use the Lenovo Power Configurator utility to determine current system power consumption For more information and to download the utility go to...

Страница 436: ...er 800b050c 2581xxxx Non redundant Insufficient Resources for RedundancySetElementName has asserted Backup Memory This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050c2581xxxx or 0x800b050c2581xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM ...

Страница 437: ... Information Prefix PLAT ID 0004 User Response 1 Open side cover to check airbuffle be instsalled well 2 Close side cover and lock the latch 3 Power On the system 806f0007 0301xxxx ProcessorElementName has Failed with IERR CPU 1 This message is for the use case when an implementation has detected a Processor Failed IERR Condition May also be shown as 806f00070301xxxx or 0x806f00070301xxxx Severity...

Страница 438: ...his message is for the use case when an implementation has detected a Processor Failed IERR Condition May also be shown as 806f00070302xxxx or 0x806f00070302xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0042 User Response 1 Update the latest level of system firmware and device drivers are installed for...

Страница 439: ...ory System Other SNMP Trap ID CIM Information Prefix PLAT ID 0084 User Response No action information only 806f0008 0a02xxxx PowerSupplyElementName has been added to container PhysicalPackageElementName Power Supply 2 This message is for the use case when an implementation has detected a Power Supply has been added May also be shown as 806f00080a02xxxx or 0x806f00080a02xxxx Severity Info Serviceab...

Страница 440: ...P Trap ID 23 CIM Information Prefix PLAT ID 0106 User Response No action information only 806f000d 0400xxxx The Drive StorageVolumeElementName has been added Drive 0 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0400xxxx or 0x806f000d0400xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critic...

Страница 441: ...se No action information only 806f000d 0402xxxx The Drive StorageVolumeElementName has been added Drive 2 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0402xxxx or 0x806f000d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLA...

Страница 442: ...This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0404xxxx or 0x806f000d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0405xxxx The Drive StorageVolumeElementName ha...

Страница 443: ...ed May also be shown as 806f000d0406xxxx or 0x806f000d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0407xxxx The Drive StorageVolumeElementName has been added Drive 7 This message is for the use case when an implementation has detected...

Страница 444: ...y also be shown as 806f000d0408xxxx or 0x806f000d0408xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0409xxxx The Drive StorageVolumeElementName has been added Drive 9 This message is for the use case when an implementation has detected a Dr...

Страница 445: ...xxx or 0x806f000d040axxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040bxxxx The Drive StorageVolumeElementName has been added Drive 11 This message is for the use case when an implementation has detected a Drive has been Added May also be ...

Страница 446: ...040cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040dxxxx The Drive StorageVolumeElementName has been added Drive 13 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d...

Страница 447: ...o Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040fxxxx The Drive StorageVolumeElementName has been added Drive 15 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d040fxxxx or 0x806f000d040fxxxx Sever...

Страница 448: ...fy support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0411xxxx The Drive StorageVolumeElementName has been added Drive 17 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0411xxxx or 0x806f000d0411xxxx Severity Info Serviceable...

Страница 449: ...cal Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0413xxxx The Drive StorageVolumeElementName has been added Drive 19 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0413xxxx or 0x806f000d0413xxxx Severity Info Serviceable No Automatically notify support N...

Страница 450: ...P Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0415xxxx The Drive StorageVolumeElementName has been added Drive 21 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0415xxxx or 0x806f000d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critic...

Страница 451: ...se No action information only 806f000d 0417xxxx The Drive StorageVolumeElementName has been added Drive 23 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0417xxxx or 0x806f000d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PL...

Страница 452: ...This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0419xxxx or 0x806f000d0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041axxxx The Drive StorageVolumeElementName ha...

Страница 453: ...ed May also be shown as 806f000d041bxxxx or 0x806f000d041bxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041cxxxx The Drive StorageVolumeElementName has been added Drive 28 This message is for the use case when an implementation has detecte...

Страница 454: ...y also be shown as 806f000d041dxxxx or 0x806f000d041dxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041exxxx The Drive StorageVolumeElementName has been added Drive 30 This message is for the use case when an implementation has detected a D...

Страница 455: ... or 0x806f000d041fxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0420xxxx The Drive StorageVolumeElementName has been added SDRAID Drive 1 This message is for the use case when an implementation has detected a Drive has been Added May also ...

Страница 456: ...0421xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0422xxxx The Drive StorageVolumeElementName has been added SDRAID Drive 3 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 80...

Страница 457: ...o Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0424xxxx The Drive StorageVolumeElementName has been added SDRAID Drive 5 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0424xxxx or 0x806f000d0424xxxx...

Страница 458: ...fy support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0426xxxx The Drive StorageVolumeElementName has been added SDRAID Drive 7 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0426xxxx or 0x806f000d0426xxxx Severity Info Servi...

Страница 459: ...cal Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0428xxxx The Drive StorageVolumeElementName has been added SDRAID Drive 9 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0428xxxx or 0x806f000d0428xxxx Severity Info Serviceable No Automatically notify sup...

Страница 460: ...P Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 042axxxx The Drive StorageVolumeElementName has been added SDRAID Drive 11 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d042axxxx or 0x806f000d042axxxx Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 461: ...o action information only 806f000d 042cxxxx The Drive StorageVolumeElementName has been added SDRAID Drive 13 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d042cxxxx or 0x806f000d042cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix...

Страница 462: ...ID Drive 15 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d042exxxx or 0x806f000d042exxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000f 220101xx The System ComputerSystem...

Страница 463: ...Name has insufficient memory for operation ABR Status This message is for the use case when an implementation has detected that the usable Memory is insufficient for operation May also be shown as 806f000f220102xx or 0x806f000f220102xx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0132 User Response This...

Страница 464: ...EFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response Firmware Error Sys Boot Status 806f000f 220104xx The System ComputerSystemElementName has encountered a motherboard failure ABR Status This message is for the use case when an implemen...

Страница 465: ... No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0764 User Response This is a UEFI detected event The UEFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response Firmware Error Sys Boot Status 806f000f 22010axx ...

Страница 466: ...server meets the minimum configuration to start see Power supply LEDs 2 Recover the server firmware from the backup page a Restart the server b At the prompt press F3 to recover the firmware 3 Update the server firmware to the latest level see Updating the firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution ...

Страница 467: ...e System ComputerSystemElementName encountered a POST Error ABR Status This message is for the use case when an implementation has detected a Post Error May also be shown as 806f000f2201ffff or 0x806f000f2201ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0184 User Response This is a UEFI detected even...

Страница 468: ... button has not been pressed complete the following steps 1 Make sure that the NMI button is not pressed 2 Replace the operator information panel cable 3 Replace the operator information panel 806f001e 2201xxxx No bootable media available for system ComputerSystemElementName No Boot Device This message is for the use case when an implementation has detected a System with No Bootable Media May also...

Страница 469: ...irmware UEFI and IMM and adapter firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Replace the affected adapters 5 Replace the riser card 6 Trained service technicians only Replace the system board 806f0...

Страница 470: ...date the code 4 Replace the affected adapters 5 Replace the riser card 6 Trained service technicians only Replace the system board One of PCI Errors 806f0021 3001xxxx Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName PCI 1 This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00213001xxxx or 0x806f00213001...

Страница 471: ... use case when an implementation has detected a Watchdog Timer Expired May also be shown as 806f00232101xxxx or 0x806f00232101xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0368 User Response No action information only 806f0028 2101xxxx Sensor SensorElementName is unavailable or degraded on management system...

Страница 472: ...tomatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0036 User Response 1 Make sure that the fans are operating There are no obstructions to the airflow front and rear of the server the air baffles are in place and correctly installed and the server cover is installed and completely closed 2 Make sure that the heat sink for microprocessor ...

Страница 473: ...tely closed 2 Make sure that the heat sink for microprocessor n is installed correctly 3 Trained technician only Replace microprocessor n n microprocessor number 806f0108 0a01xxxx PowerSupplyElementName has Failed Power Supply 1 This message is for the use case when an implementation has detected a Power Supply has failed May also be shown as 806f01080a01xxxx or 0x806f01080a01xxxx Severity Error S...

Страница 474: ...ategory Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Response 1 Reseat power supply n 2 If the power on LED is not lit and the power supply error LED is lit replace power supply n 3 If both the power on LED and the power supply error LED are not lit see Power problems for more information n power supply number 806f0109 1301xxxx PowerSupplyElementName has been Power Cycled...

Страница 475: ...lies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the...

Страница 476: ... the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the sys...

Страница 477: ...ins any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the se...

Страница 478: ...Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconn...

Страница 479: ...ed microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 2006xxxx Uncorrectable error detected for PhysicalMemoryElementName on Sub...

Страница 480: ... error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2007xxxx or 0x806f010c2007xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Respon...

Страница 481: ... remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory ch...

Страница 482: ... event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socke...

Страница 483: ... check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server fir...

Страница 484: ...is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEF...

Страница 485: ...aged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affecte...

Страница 486: ...nect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 200exxxx Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c200exxxx or 0x...

Страница 487: ...x806f010c200fxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support w...

Страница 488: ...or minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same...

Страница 489: ...blem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system boar...

Страница 490: ...r contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If...

Страница 491: ...technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the ...

Страница 492: ... affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f010c 2015xxxx Uncorrectable error detected for PhysicalMemoryElementName...

Страница 493: ...tected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2016xxxx or 0x806f010c2016xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note ...

Страница 494: ...stall or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different m...

Страница 495: ...gs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins fo...

Страница 496: ...connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the s...

Страница 497: ... backplane n hard disk drive number 806f010d 0401xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 1 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0401xxxx or 0x806f010d0401xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk ...

Страница 498: ...LAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Har...

Страница 499: ...ive 4 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0404xxxx or 0x806f010d0404xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat ...

Страница 500: ...1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0406xxxx The Drive StorageVolumeElementName has been disabled due to a detected...

Страница 501: ...407xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 502: ...ach time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0409xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 9 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0409xxxx or 0x806f010d0409xxxx Severit...

Страница 503: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 504: ...e to a detected fault Drive 12 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040cxxxx or 0x806f010d040cxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic ...

Страница 505: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 040exxxx The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 506: ...06f010d040fxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace t...

Страница 507: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0411xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 17 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0411xxxx or 0x806f010d0411xxxx Severity Error...

Страница 508: ... support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting...

Страница 509: ...etected fault Drive 20 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0414xxxx or 0x806f010d0414xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 510: ...1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0416xxxx The Drive StorageVolumeElementName has been disabled due to a detected...

Страница 511: ...417xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 512: ...ach time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0419xxxx The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 25 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0419xxxx or 0x806f010d0419xxxx Severi...

Страница 513: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 514: ...e to a detected fault Drive 28 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041cxxxx or 0x806f010d041cxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic ...

Страница 515: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 041exxxx The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 516: ...xx or 0x806f010d041fxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 ...

Страница 517: ...olution before you update the code 3 Trained technician only Replace the system board 806f0113 0301xxxx A bus timeout has occurred on system ComputerSystemElementName CPU 1 PECI This message is for the use case when an implementation has detected a Bus Timeout May also be shown as 806f01130301xxxx or 0x806f01130301xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category C...

Страница 518: ...ician only Reseat the microprocessor and then restart the server 2 Trained technician only Replace microprocessor n n microprocessor number 806f0123 2101xxxx Reboot of system ComputerSystemElementName initiated by WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred May also be shown as 806f01232101xxxx or 0x806f0123...

Страница 519: ...on Prefix PLAT ID 0392 User Response Please ensure the PCI riser 1 has been installed correctly 806f0207 0301xxxx ProcessorElementName has Failed with FRB1 BIST condition CPU 1 This message is for the use case when an implementation has detected a Processor Failed FRB1 BIST condition May also be shown as 806f02070301xxxx or 0x806f02070301xxxx Severity Error Serviceable Yes Automatically notify sup...

Страница 520: ...RB1 BIST condition May also be shown as 806f02070302xxxx or 0x806f02070302xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0044 User Response 1 Update the latest level of system firmware and device drivers are installed for all adapters and standard devices such as UEFI IMM Ethernet and SAS Important Som...

Страница 521: ...ates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA program 3 Reseat the adapter 4 Replace the adapter 5 Trained technician only Replace microprocessor n n microprocessor number 6 Trained technician only Replace the system board One of the CPUs 806f020d 0400xxxx Failure Predicted on dri...

Страница 522: ...ElementName Drive 1 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0401xxxx or 0x806f020d0401xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on driv...

Страница 523: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0403xxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 524: ...6f020d0404xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace...

Страница 525: ...Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0406xxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0406xxxx or 0x806f020d0406xxxx Severity Wa...

Страница 526: ... support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restartin...

Страница 527: ...terSystemElementName Drive 9 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0409xxxx or 0x806f020d0409xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 528: ...1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 040bxxxx Failure Predicted on drive StorageVolumeElementName for array Computer...

Страница 529: ...0cxxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 530: ...time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 040exxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040exxxx or 0x806f020d040exxxx Sev...

Страница 531: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the se...

Страница 532: ...y ComputerSystemElementName Drive 17 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0411xxxx or 0x806f020d0411xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagno...

Страница 533: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0413xxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemEl...

Страница 534: ...6f020d0414xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace...

Страница 535: ...ard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0416xxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0416xxxx or 0x806f020d0416xxxx Severity Wa...

Страница 536: ... support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restartin...

Страница 537: ...erSystemElementName Drive 25 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0419xxxx or 0x806f020d0419xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 538: ...1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 041bxxxx Failure Predicted on drive StorageVolumeElementName for array Computer...

Страница 539: ...1cxxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fol...

Страница 540: ...time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 041exxxx Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041exxxx or 0x806f020d041exxxx Sev...

Страница 541: ...rt Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ...

Страница 542: ...6f03080a01xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response 1 Reconnect the power cords 2 Check power supply n LED 3 See Power supply LEDs for more information n power supply number 806f0308 0a02xxxx PowerSupplyElementName has lost input Power Supply 2 This message is for the use case when an...

Страница 543: ...y Scrub failure May also be shown as 806f030c2001xxxx or 0x806f030c2001xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H2...

Страница 544: ...upport No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to t...

Страница 545: ...DIMMs 4 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem follows the DIMM replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trai...

Страница 546: ...M replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technici...

Страница 547: ...ed microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician only Replace the affected microprocessor 806f030c 2006xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as...

Страница 548: ...upport No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to t...

Страница 549: ...DIMMs 4 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem follows the DIMM replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trai...

Страница 550: ... replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technicia...

Страница 551: ...ed microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician only Replace the affected microprocessor 806f030c 200bxxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown a...

Страница 552: ...upport No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to t...

Страница 553: ...DIMMs 4 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem follows the DIMM replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trai...

Страница 554: ... replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technicia...

Страница 555: ...ed microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician only Replace the affected microprocessor 806f030c 2010xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown a...

Страница 556: ...upport No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to t...

Страница 557: ...DIMMs 4 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem follows the DIMM replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trai...

Страница 558: ... replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technicia...

Страница 559: ...ed microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician only Replace the affected microprocessor 806f030c 2015xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown a...

Страница 560: ...upport No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to t...

Страница 561: ...DIMMs 4 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 5 If the problem follows the DIMM replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trai...

Страница 562: ...replace the failing DIMM 6 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician...

Страница 563: ...m board 7 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 8 Trained technician only Replace the affected microprocessor One of the DIMMs 806f030d 0400xxxx Hot Spare enabled for ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected a...

Страница 564: ...en Enabled May also be shown as 806f030d0402xxxx or 0x806f030d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0403xxxx Hot Spare enabled for ComputerSystemElementName Drive 3 This message is for the use case when an implementation has detected a Hot S...

Страница 565: ...e shown as 806f030d0404xxxx or 0x806f030d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0405xxxx Hot Spare enabled for ComputerSystemElementName Drive 5 This message is for the use case when an implementation has detected a Hot Spare has been Enabled...

Страница 566: ...30d0406xxxx or 0x806f030d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0407xxxx Hot Spare enabled for ComputerSystemElementName Drive 7 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be sho...

Страница 567: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0409xxxx Hot Spare enabled for ComputerSystemElementName Drive 9 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0409xxxx or 0x806f0...

Страница 568: ... Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 040bxxxx Hot Spare enabled for ComputerSystemElementName Drive 11 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d040bxxxx or 0x806f030d040bxxxx S...

Страница 569: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 040dxxxx Hot Spare enabled for ComputerSystemElementName Drive 13 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d040dxxxx or 0x806f030d040dxxxx Severity Info Serviceable No A...

Страница 570: ...o Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 040fxxxx Hot Spare enabled for ComputerSystemElementName Drive 15 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d040fxxxx or 0x806f030d040fxxxx Severity Info Serviceable No Automatically noti...

Страница 571: ... ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0411xxxx Hot Spare enabled for ComputerSystemElementName Drive 17 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0411xxxx or 0x806f030d0411xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Oth...

Страница 572: ...er Response No action information only 806f030d 0413xxxx Hot Spare enabled for ComputerSystemElementName Drive 19 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0413xxxx or 0x806f030d0413xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLA...

Страница 573: ...e is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d0415xxxx or 0x806f030d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0416xxxx Hot Spare enabled for ComputerSystemElementName Drive 22...

Страница 574: ...en Enabled May also be shown as 806f030d0417xxxx or 0x806f030d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 0418xxxx Hot Spare enabled for ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected a Hot ...

Страница 575: ...e shown as 806f030d0419xxxx or 0x806f030d0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 041axxxx Hot Spare enabled for ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected a Hot Spare has been Enable...

Страница 576: ...30d041bxxxx or 0x806f030d041bxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 041cxxxx Hot Spare enabled for ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be sh...

Страница 577: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f030d 041exxxx Hot Spare enabled for ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected a Hot Spare has been Enabled May also be shown as 806f030d041exxxx or 0x806f...

Страница 578: ...nfo Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0170 User Response No action information only 806f0313 1701xxxx A software NMI has occurred on system ComputerSystemElementName NMI State This message is for the use case when an implementation has detected a Software NMI May also be shown as 806f03131701xxxx or 0x806f03131701...

Страница 579: ...ycle by Watchdog occurred May also be shown as 806f03232101xxxx or 0x806f03232101xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0374 User Response No action information only 806f040c 2001xxxx PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 1 This message is for the use case when an imp...

Страница 580: ...tem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2002xxxx or 0x806f040c2002xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM wa...

Страница 581: ... the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2004xxxx PhysicalMemoryElementName Disabled...

Страница 582: ...xx or 0x806f040c2005xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the s...

Страница 583: ...emory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2007xxxx PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2007x...

Страница 584: ...cally notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable ret...

Страница 585: ...ElementName DIMM 10 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200axxxx or 0x806f040c200axxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disable...

Страница 586: ...d follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 200cxxxx PhysicalMemoryElementName ...

Страница 587: ...806f040c200dxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 ...

Страница 588: ... this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 200fxxxx PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f0...

Страница 589: ...tify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip ...

Страница 590: ...m MemoryElementName DIMM 18 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2012xxxx or 0x806f040c2012xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was...

Страница 591: ... the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2014xxxx PhysicalMemoryElementName Disabled...

Страница 592: ...xx or 0x806f040c2015xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the s...

Страница 593: ...mory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 806f040c 2017xxxx PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2017x...

Страница 594: ...ally notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the Lenovo support website for an applicable reta...

Страница 595: ... DIMMs 806f0413 2582xxxx A PCI PERR has occurred on system ComputerSystemElementName PCIs This message is for the use case when an implementation has detected a PCI PERR May also be shown as 806f04132582xxxx or 0x806f04132582xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0232 User Response 1 Check the...

Страница 596: ...PLAT ID 0062 User Response 1 Make sure that the installed microprocessors are compatible with each other 2 Trained technician only Reseat microprocessor n 3 Trained technician only Replace microprocessor n n microprocessor number 806f0507 0302xxxx ProcessorElementName has a Configuration Mismatch CPU 2 This message is for the use case when an implementation has detected a Processor Configuration M...

Страница 597: ...Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response 1 Make sure that the installed microprocessors are compatible with each other 2 Trained technician only Reseat microprocessor n 3 Trained technician only Replace microprocessor n n microprocessor number One of the CPUs 806f050c 2001xxxx Memory Logging Limit ...

Страница 598: ...y foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server f...

Страница 599: ...technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the ...

Страница 600: ...place the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f050c 2004xxx...

Страница 601: ...er source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f050c 2005xxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2005xxxx or 0x806f050c2005xxxx Severi...

Страница 602: ...50c2006xxxx or 0x806f050c2006xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the...

Страница 603: ...for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the sam...

Страница 604: ...channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a d...

Страница 605: ...ck the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmwar...

Страница 606: ...terial or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware vers...

Страница 607: ...move the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the powe...

Страница 608: ... microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f050c 200dxxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsy...

Страница 609: ...r PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200exxxx or 0x806f050c200exxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Resp...

Страница 610: ...ime you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a d...

Страница 611: ...icated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affecte...

Страница 612: ...rained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected m...

Страница 613: ...foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server fir...

Страница 614: ...m board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect ...

Страница 615: ...f a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 8 Manually re enable all affected DIMMs if the server firmware version is older than UEFI v1 10 If the server firmware version is UEFI v1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microproc...

Страница 616: ...1 10 or newer disconnect and reconnect the server to the power source and restart the server 9 Trained Service technician only Replace the affected microprocessor 806f050c 2016xxxx Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May a...

Страница 617: ...ing Limit has been Reached May also be shown as 806f050c2017xxxx or 0x806f050c2017xxxx Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Re...

Страница 618: ...ting the server 1 Refer to TIP H212293 for minimum code level 2 Check the Lenovo support website for an applicable retain tip or firmware update that applies to this memory error 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technicia...

Страница 619: ...ocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found rep...

Страница 620: ...ce the hard disk drive that is indicated by a lit status LED 806f050d 0401xxxx Array ComputerSystemElementName is in critical condition Drive 1 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0401xxxx or 0x806f050d0401xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk driv...

Страница 621: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 622: ...tical condition Drive 4 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0404xxxx or 0x806f050d0404xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard d...

Страница 623: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0406xxxx Array ComputerSystemElementName is in critical condition Drive 6 This message is for the use case when an implementation has detected tha...

Страница 624: ...806f050d0407xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Repl...

Страница 625: ...ard disk drive that is indicated by a lit status LED 806f050d 0409xxxx Array ComputerSystemElementName is in critical condition Drive 9 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0409xxxx or 0x806f050d0409xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 626: ...egory Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED ...

Страница 627: ...ndition Drive 12 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040cxxxx or 0x806f050d040cxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 628: ... disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 040exxxx Array ComputerSystemElementName is in critical condition Drive 14 This message is for the use case when an implementation has det...

Страница 629: ...040fxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 630: ...e the hard disk drive that is indicated by a lit status LED 806f050d 0411xxxx Array ComputerSystemElementName is in critical condition Drive 17 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0411xxxx or 0x806f050d0411xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk driv...

Страница 631: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 632: ...tical condition Drive 20 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0414xxxx or 0x806f050d0414xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard ...

Страница 633: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0416xxxx Array ComputerSystemElementName is in critical condition Drive 22 This message is for the use case when an implementation has detected th...

Страница 634: ...806f050d0417xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Repl...

Страница 635: ...rd disk drive that is indicated by a lit status LED 806f050d 0419xxxx Array ComputerSystemElementName is in critical condition Drive 25 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0419xxxx or 0x806f050d0419xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 636: ...egory Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED ...

Страница 637: ...ndition Drive 28 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041cxxxx or 0x806f050d041cxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 638: ... disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 041exxxx Array ComputerSystemElementName is in critical condition Drive 30 This message is for the use case when an implementation has det...

Страница 639: ...806f050d041fxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Repl...

Страница 640: ...lution before you update the code 4 Make sure that the adapter is supported For a list of supported optional devices see http www lenovo com serverproven 5 Remove both adapters 6 Replace the PCIe adapters 7 Replace the riser card 806f052b 2101xxxx Invalid or Unsupported firmware or software was detected on system ComputerSystemElementName IMM2 FW Failover This message is for the use case when an i...

Страница 641: ...x error for ProcessorElementName has asserted CPU 1 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted May also be shown as 806f06070301xxxx or 0x806f06070301xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0816 User Response 1 Update the latest level of system f...

Страница 642: ...UEFI IMM Ethernet and SAS Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA program 3 Reseat the adapter 4 Replace the adapter 5 Trained technician only Replace microprocessor n n microprocessor numbe...

Страница 643: ...date the code 2 Run the DSA program 3 Reseat the adapter 4 Replace the adapter 5 Trained technician only Replace microprocessor n n microprocessor number 6 Trained technician only Replace the system board One of the CPUs 806f0608 1301xxxx PowerSupplyElementName has a Configuration Mismatch PS Configuration This message is for the use case when an implementation has detected a Power Supply with a C...

Страница 644: ...Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0401xxxx Array ComputerSystemElementName has failed Drive 1 This message is ...

Страница 645: ...06f060d0402xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the ...

Страница 646: ...cated by a lit status LED 806f060d 0404xxxx Array ComputerSystemElementName has failed Drive 4 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0404xxxx or 0x806f060d0404xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 ...

Страница 647: ...ion Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0406xxxx Array ComputerSystemElementName has failed Drive 6 This message is for the ...

Страница 648: ...f060d0407xxxx or 0x806f060d0407xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID ad...

Страница 649: ... a lit status LED 806f060d 0409xxxx Array ComputerSystemElementName has failed Drive 9 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0409xxxx or 0x806f060d0409xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Res...

Страница 650: ...Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 040bxxxx Array ComputerSystemElementName has failed Drive 11 This message is...

Страница 651: ...cxxxx or 0x806f060d040cxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 ...

Страница 652: ...ated by a lit status LED 806f060d 040exxxx Array ComputerSystemElementName has failed Drive 14 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040exxxx or 0x806f060d040exxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 ...

Страница 653: ...ion Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0410xxxx Array ComputerSystemElementName has failed Drive 16 This message is for the...

Страница 654: ...f060d0411xxxx or 0x806f060d0411xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID ad...

Страница 655: ...a lit status LED 806f060d 0413xxxx Array ComputerSystemElementName has failed Drive 19 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0413xxxx or 0x806f060d0413xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Res...

Страница 656: ...Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0415xxxx Array ComputerSystemElementName has failed Drive 21 This message is...

Страница 657: ...6xxxx or 0x806f060d0416xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 ...

Страница 658: ...ated by a lit status LED 806f060d 0418xxxx Array ComputerSystemElementName has failed Drive 24 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0418xxxx or 0x806f060d0418xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 ...

Страница 659: ...ion Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 041axxxx Array ComputerSystemElementName has failed Drive 26 This message is for the...

Страница 660: ...f060d041bxxxx or 0x806f060d041bxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID ad...

Страница 661: ...a lit status LED 806f060d 041dxxxx Array ComputerSystemElementName has failed Drive 29 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041dxxxx or 0x806f060d041dxxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Res...

Страница 662: ...Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 041fxxxx Array ComputerSystemElementName has failed Drive 31 This message is...

Страница 663: ...ed a Memory DIMM configuration error has been corrected May also be shown as 806f070c2001xxxx or 0x806f070c2001xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2002xxxx Con...

Страница 664: ...y DIMM configuration error has been corrected May also be shown as 806f070c2003xxxx or 0x806f070c2003xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2004xxxx Configuration...

Страница 665: ...DIMM 5 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2005xxxx or 0x806f070c2005xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following th...

Страница 666: ...the system publication 806f070c 2007xxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2007xxxx or 0x806f070c2007xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Me...

Страница 667: ...26 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2009xxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2009xxxx or 0x806f070c2...

Страница 668: ... No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 200bxxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected a Memory DIMM config...

Страница 669: ...omatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 200dxxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has dete...

Страница 670: ...erity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 200fxxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case ...

Страница 671: ...r 0x806f070c2010xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2011xxxx Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This mess...

Страница 672: ...o be shown as 806f070c2012xxxx or 0x806f070c2012xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2013xxxx Configuration Error for PhysicalMemoryElementName on Subsystem Mem...

Страница 673: ...May also be shown as 806f070c2014xxxx or 0x806f070c2014xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2015xxxx Configuration Error for PhysicalMemoryElementName on Subsys...

Страница 674: ...y DIMM configuration error has been corrected May also be shown as 806f070c2016xxxx or 0x806f070c2016xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2017xxxx Configuration...

Страница 675: ...MM 24 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2018xxxx or 0x806f070c2018xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the...

Страница 676: ...ed and following the memory population chart in the system publication One of the DIMMs 806f070d 0400xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0400xxxx or 0x806f070d0400xxxx Severity Info Serviceable No Automatically notify supp...

Страница 677: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0402xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0402xxxx or 0x806f070d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Categor...

Страница 678: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0404xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0404xxxx or 0x806f070d0404xxxx Severity Info Serviceable No Automatically notify support No Alert...

Страница 679: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0406xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0406xxxx or 0x806f070d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Categor...

Страница 680: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0408xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0408xxxx or 0x806f070d0408xxxx Severity Info Serviceable No Automatically notify support No Alert...

Страница 681: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 040axxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d040axxxx or 0x806f070d040axxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 682: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040cxxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d040cxxxx or 0x806f070d040cxxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 683: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 040exxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d040exxxx or 0x806f070d040exxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 684: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0410xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0410xxxx or 0x806f070d0410xxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 685: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0412xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0412xxxx or 0x806f070d0412xxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 686: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0414xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0414xxxx or 0x806f070d0414xxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 687: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0416xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0416xxxx or 0x806f070d0416xxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 688: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0418xxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0418xxxx or 0x806f070d0418xxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 689: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 041axxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d041axxxx or 0x806f070d041axxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 690: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041cxxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d041cxxxx or 0x806f070d041cxxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 691: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 041exxxx Rebuild in progress for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d041exxxx or 0x806f070d041exxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 692: ...Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0420xxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 1 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0420xxxx or 0x806f070d0420xxxx Severity Info Serviceable No Automatically notify support No A...

Страница 693: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0422xxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 3 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0422xxxx or 0x806f070d0422xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 694: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0424xxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 5 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0424xxxx or 0x806f070d0424xxxx Severity Info Serviceable No Automatically notify support N...

Страница 695: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 0426xxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 7 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0426xxxx or 0x806f070d0426xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 696: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0428xxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 9 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0428xxxx or 0x806f070d0428xxxx Severity Info Serviceable No Automatically notify support N...

Страница 697: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 042axxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 11 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d042axxxx or 0x806f070d042axxxx Severity Info Serviceable No Automatically notify support No Alert...

Страница 698: ...IM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 042cxxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 13 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d042cxxxx or 0x806f070d042cxxxx Severity Info Serviceable No Automatically notify support ...

Страница 699: ...mation Prefix PLAT ID 0178 User Response No action information only 806f070d 042exxxx Rebuild in progress for Array in system ComputerSystemElementName SDRAID Drive 15 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d042exxxx or 0x806f070d042exxxx Severity Info Serviceable No Automatically notify support No Alert...

Страница 700: ... Prefix PLAT ID 0450 User Response No action information only IMM Recovery 806f072b 2201xxxx A successful software or firmware change was detected on system ComputerSystemElementName Bkup Auto Update This message is for the use case when an implementation has detected a Successful Software or Firmware Change May also be shown as 806f072b2201xxxx or 0x806f072b2201xxxx Severity Info Serviceable No A...

Страница 701: ...esponse No action information only 806f0807 0302xxxx ProcessorElementName has been Disabled CPU 2 This message is for the use case when an implementation has detected a Processor has been Disabled May also be shown as 806f08070302xxxx or 0x806f08070302xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User ...

Страница 702: ...le Bus Error has occurred on system ComputerSystemElementName DIMMs This message is for the use case when an implementation has detected a Bus Uncorrectable Error May also be shown as 806f08132581xxxx or 0x806f08132581xxxx Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response 1 Check the syste...

Страница 703: ...P Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response 1 Check the system event log 2 Trained technician only Remove the failing microprocessor from the system board see Removing a microprocessor and heat sink 3 Check for a server firmware update Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that...

Страница 704: ...at the latest level of code is supported for the cluster solution before you update the code 4 Make sure that the two microprocessors are matching 5 Trained technician only Replace the system board 806f0823 2101xxxx Watchdog Timer interrupt occurred for WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Watchdog Timer interrupt occurred May als...

Страница 705: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2002xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 2 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2002xxxx or 0x806f090c2002xxxx Severity Warning Serviceable Yes Automatically...

Страница 706: ...ort No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2004xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 4 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2004xx...

Страница 707: ...rviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2006xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 6 This message is for the use case when an implementation has detected Memory has been Thrott...

Страница 708: ...090c2007xxxx or 0x806f090c2007xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2008xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 8 This message is for the use case when...

Страница 709: ...ay also be shown as 806f090c2009xxxx or 0x806f090c2009xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200axxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 10 This message...

Страница 710: ...ubsystem MemoryElementName Throttled DIMM 11 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200bxxxx or 0x806f090c200bxxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the se...

Страница 711: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200dxxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 13 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200dxxxx or 0x806f090c200dxxxx Severity Warning Serviceable Yes Automaticall...

Страница 712: ...ort No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200fxxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 15 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200fx...

Страница 713: ...rviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2011xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 17 This message is for the use case when an implementation has detected Memory has been Throt...

Страница 714: ...090c2012xxxx or 0x806f090c2012xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2013xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 19 This message is for the use case whe...

Страница 715: ...ay also be shown as 806f090c2014xxxx or 0x806f090c2014xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2015xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 21 This message...

Страница 716: ...ubsystem MemoryElementName Throttled DIMM 22 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2016xxxx or 0x806f090c2016xxxx Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the se...

Страница 717: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2018xxxx PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 24 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2018xxxx or 0x806f090c2018xxxx Severity Warning Serviceable Yes Automaticall...

Страница 718: ...to the airflow front and rear of the server that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications 3 Make sure that the heat sink for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 806f0a0...

Страница 719: ...emoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2001xxxx or 0x806f0a0c2001xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 Us...

Страница 720: ...o the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2003xxxx An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsyste...

Страница 721: ...emperature Condition for Memory that has been Detected May also be shown as 806f0a0c2004xxxx or 0x806f0a0c2004xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place a...

Страница 722: ...hat the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2006xxxx An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implement...

Страница 723: ...s 806f0a0c2007xxxx or 0x806f0a0c2007xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and complete...

Страница 724: ...perature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2009xxxx An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected M...

Страница 725: ...y Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature i...

Страница 726: ...3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200cxxxx An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200cxxxx ...

Страница 727: ...iceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the...

Страница 728: ...x An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200fxxxx or 0x806f0a0c200fxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critica...

Страница 729: ...Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f...

Страница 730: ...lementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2012xxxx or 0x806f0a0c2012xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Re...

Страница 731: ...ere are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2014xxxx An Over Temperature Condition has been detected on the PhysicalMemo...

Страница 732: ...mentName DIMM 21 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2015xxxx or 0x806f0a0c2015xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans ...

Страница 733: ...rflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2017xxxx An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem Memory...

Страница 734: ...tation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2018xxxx or 0x806f0a0c2018xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that t...

Страница 735: ...croprocessor number 806f0a13 0302xxxx A Fatal Bus Error has occurred on system ComputerSystemElementName CPU 2 PECI This message is for the use case when an implementation has detected a Bus Fatal Error May also be shown as 806f0a130302xxxx or 0x806f0a130302xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ...

Страница 736: ...on Prefix PLAT ID 0477 User Response No action information only 81010202 0701xxxx Numeric sensor NumericSensorElementName going low lower critical has deasserted CMOS Battery This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102020701xxxx or 0x810102020701xxxx Severity Info Serviceable No Automatically noti...

Страница 737: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d02xxxx Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 2 Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d02xxxx or 0x810102041d02xxxx Severity Info Serviceable No Automatically no...

Страница 738: ...IM Information Prefix PLAT ID 0481 User Response No action information only 81010204 1d04xxxx Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 4 Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d04xxxx or 0x810102041d04xxxx Severity Info Serviceable No Automati...

Страница 739: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1402xxxx Numeric sensor NumericSensorElementName going high upper non critical has deasserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011402xxxx or 0x810107011402xxxx Severity Info Serviceable No Aut...

Страница 740: ...IM Information Prefix PLAT ID 0491 User Response No action information only 81010701 1404xxxx Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM CD VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011404xxxx or 0x810107011404xxxx Severity Info Service...

Страница 741: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1406xxxx Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011406xxxx or 0x810107011406xxxx Severity Info Serviceable No ...

Страница 742: ... Information Prefix PLAT ID 0491 User Response No action information only 81010701 3701xxxx Numeric sensor NumericSensorElementName going high upper non critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107013701xxxx or 0x810107013701xxxx Severity Info Serviceable ...

Страница 743: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1402xxxx Numeric sensor NumericSensorElementName going high upper critical has deasserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011402xxxx or 0x810109011402xxxx Severity Info Serviceable No Automatical...

Страница 744: ...IM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1404xxxx Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM CD VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011404xxxx or 0x810109011404xxxx Severity Info Serviceable No ...

Страница 745: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1406xxxx Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM GH VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011406xxxx or 0x810109011406xxxx Severity Info Serviceable No Automati...

Страница 746: ... Information Prefix PLAT ID 0495 User Response No action information only 81010901 3701xxxx Numeric sensor NumericSensorElementName going high upper critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109013701xxxx or 0x810109013701xxxx Severity Info Serviceable No Autom...

Страница 747: ... 0495 User Response No action information only SysBrd 3 3V SysBrd 5V 81010b01 1401xxxx Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011401xxxx or 0x81010b011401xxxx Severity Info Serviceable...

Страница 748: ...M Information Prefix PLAT ID 0499 User Response No action information only 81010b01 1403xxxx Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM AB VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011403xxxx or 0x81010b011403xxxx Severity Info Se...

Страница 749: ...mation Prefix PLAT ID 0499 User Response No action information only 81010b01 1405xxxx Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011405xxxx or 0x81010b011405xxxx Severity Info Serviceab...

Страница 750: ... 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81010b01 2d01xxxx Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted PCH Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b012d01xxxx or 0x81010b012d01xxxx Severity Info Serv...

Страница 751: ...y Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81030006 2101xxxx Sensor SensorElementName has asserted Sig Verify Fail This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300062101xxxx or 0x810300062101xxxx Severity Info Serviceable No Automatically notify support No A...

Страница 752: ...12 2301xxxx Sensor SensorElementName has asserted OS RealTime Mod This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300122301xxxx or 0x810300122301xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Response No action information only 8103...

Страница 753: ...ion has detected a Sensor has deasserted May also be shown as 8103010c2581xxxx or 0x8103010c2581xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 81030112 0601xxxx Sensor SensorElementName has deasserted SMM Mode This message is for the use case when an implementati...

Страница 754: ... critical from normal May also be shown as 8107010d2582xxxx or 0x8107010d2582xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response No action information only 8107010f 2201xxxx Sensor SensorElementName has deasserted the transition from normal to non critical state GPT Status This message is f...

Страница 755: ...m normal May also be shown as 8107010f2582xxxx or 0x8107010f2582xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0521 User Response No action information only 81070128 2e01xxxx Sensor SensorElementName has deasserted the transition from normal to non critical state ME Recovery This message is for the use c...

Страница 756: ...rom critical May also be shown as 810702010301xxxx or 0x810702010301xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070201 0302xxxx Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 OverTemp This message is for the us...

Страница 757: ...m critical May also be shown as 810702020701xxxx or 0x810702020701xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070204 0a01xxxx Sensor SensorElementName has transitioned to a less severe state from critical PS 1 Fan Fault This message is for the use case...

Страница 758: ... from critical May also be shown as 810702040a02xxxx or 0x810702040a02xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070208 0a01xxxx Sensor SensorElementName has transitioned to a less severe state from critical PS 1 Therm Fault This message is for t...

Страница 759: ...critical May also be shown as 810702080a02xxxx or 0x810702080a02xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107020d 2582xxxx Sensor SensorElementName has transitioned to a less severe state from critical RAID Vol State This message is for the use case whe...

Страница 760: ...e from critical May also be shown as 8107020f2201xxxx or 0x8107020f2201xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107020f 2582xxxx Sensor SensorElementName has transitioned to a less severe state from critical I O Resources This message is for the use c...

Страница 761: ...tical May also be shown as 810702142201xxxx or 0x810702142201xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 81070219 0701xxxx Sensor SensorElementName has transitioned to a less severe state from critical SysBrd Fault This message is for the use case when an...

Страница 762: ...e from critical May also be shown as 8107021b0301xxxx or 0x8107021b0301xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only 8107021b 0302xxxx Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 QPILinkErr This message is for the us...

Страница 763: ...282e01xxxx or 0x810702282e01xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0523 User Response No action information only ME Flash Error 81070301 0301xxxx Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state CPU 1 OverTemp This message is for the use case whe...

Страница 764: ... has deasserted May also be shown as 810703010302xxxx or 0x810703010302xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0525 User Response No action information only 8107030d 2582xxxx Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state RAID Vol State Thi...

Страница 765: ... as 810706080a01xxxx or 0x810706080a01xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0531 User Response No action information only PS1 12V OV Fault PS1 12V UV Fault PS1 12Vaux Fault 81070608 0a02xxxx Sensor SensorElementName has deasserted the transition to non recoverable PS2 12V OC Fault This message i...

Страница 766: ...ion has detected a Device was removed May also be shown as 810801171001xxxx or 0x810801171001xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0537 User Response No action information only 81080117 1002xxxx Device LogicalDeviceElementName has been removed from unit PhysicalPackageElementName SDCard1 Presence Th...

Страница 767: ...d a Device was removed May also be shown as 810801171003xxxx or 0x810801171003xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0537 User Response No action information only 810b010a 1e81xxxx Redundancy Lost for RedundancySetElementName has deasserted Fan Zone 1 This message is for the use case when Redundancy ...

Страница 768: ...0c2581xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0803 User Response No action information only 810b0309 1301xxxx Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has deasserted Power Resource This message is for the use case when a Redundan...

Страница 769: ...nt Sufficient Resources May also be shown as 810b030c2581xxxx or 0x810b030c2581xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0807 User Response No action information only 810b0509 1301xxxx Non redundant Insufficient Resources for RedundancySetElementName has deasserted Power Resource This message is fo...

Страница 770: ...ient Resources May also be shown as 810b050a1e81xxxx or 0x810b050a1e81xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050c 2581xxxx Non redundant Insufficient Resources for RedundancySetElementName has deasserted Backup Memory This message is for th...

Страница 771: ...hown as 816f00051701xxxx or 0x816f00051701xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0005 User Response No action information only 816f0007 0301xxxx ProcessorElementName has Recovered from IERR CPU 1 This message is for the use case when an implementation has detected a Processor Recovered IERR Condi...

Страница 772: ...s 816f00070302xxxx or 0x816f00070302xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0043 User Response No action information only 816f0008 0a01xxxx PowerSupplyElementName has been removed from container PhysicalPackageElementName Power Supply 1 This message is for the use case when an implementation has de...

Страница 773: ... been removed May also be shown as 816f00080a02xxxx or 0x816f00080a02xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0085 User Response No action information only 816f0009 1301xxxx PowerSupplyElementName has been turned on Host Power This message is for the use case when an implementation has detected a Power...

Страница 774: ...able Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk dr...

Страница 775: ...kplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0402xxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 2 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0402xxxx or 0x816f000d0402xxxx Severity Error Serviceable Yes Automati...

Страница 776: ...r Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the har...

Страница 777: ...drive 816f000d 0405xxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 5 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0405xxxx or 0x816f000d0405xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Inf...

Страница 778: ...y Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0407xxxx The Drive StorageVolumeElementNa...

Страница 779: ...ysicalPackageElementName Drive 8 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0408xxxx or 0x816f000d0408xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive ...

Страница 780: ...n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 040axxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 10 This message is for the use case when an implementati...

Страница 781: ... 816f000d040bxxxx or 0x816f000d040bxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the...

Страница 782: ... and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 040dxxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 13 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040dxxxx or 0x816f000d040dxxxx Severity Error Serviceable Yes...

Страница 783: ...eable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk d...

Страница 784: ...d disk drive 816f000d 0410xxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 16 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0410xxxx or 0x816f000d0410xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5...

Страница 785: ...al Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0412xxxx The Drive StorageVolumeElementName has b...

Страница 786: ...unit PhysicalPackageElementName Drive 19 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0413xxxx or 0x816f000d0413xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard dis...

Страница 787: ...isk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0415xxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 21 This message is for the use case when an implementation has d...

Страница 788: ...shown as 816f000d0416xxxx or 0x816f000d0416xxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware ar...

Страница 789: ...kplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0418xxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 24 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0418xxxx or 0x816f000d0418xxxx Severity Error Serviceable Yes Automat...

Страница 790: ...r Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the har...

Страница 791: ...rive 816f000d 041bxxxx The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 27 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041bxxxx or 0x816f000d041bxxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Inf...

Страница 792: ...y Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 041dxxxx The Drive StorageVolumeElementNa...

Страница 793: ...sicalPackageElementName Drive 30 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041exxxx or 0x816f000d041exxxx Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive ...

Страница 794: ... drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000f 2201ffff The System ComputerSystemElementName has detected a POST Error deassertion ABR Status This message is for the use case when an implementation ...

Страница 795: ...le No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0223 User Response No action information only 816f0021 2201xxxx Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName No Op ROM Space This message is for the use case when an implementation has detected a Fault condition in a slot has been re...

Страница 796: ...o Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only One of PCI Error 816f0021 3001xxxx Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName PCI 1 This message is for the use case when an implementation has detected a Fault condition in ...

Страница 797: ...2101xxxx or 0x816f00282101xxxx Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0399 User Response No action information only 816f0107 0301xxxx An Over Temperature Condition has been removed on ProcessorElementName CPU 1 This message is for the use case when an implementation has detected a Over Temperature Con...

Страница 798: ...xxx or 0x816f01070302xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response No action information only 816f0108 0a01xxxx PowerSupplyElementName has returned to OK status Power Supply 1 This message is for the use case when an implementation has detected a Power Supply return to normal op...

Страница 799: ... Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response No action information only 816f010c 2001xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory uncorrectable error rec...

Страница 800: ...16f010c2002xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2003xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected a Memo...

Страница 801: ...x or 0x816f010c2004xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2005xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detecte...

Страница 802: ...shown as 816f010c2006xxxx or 0x816f010c2006xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2007xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an im...

Страница 803: ...shown as 816f010c2008xxxx or 0x816f010c2008xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2009xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an im...

Страница 804: ...ery May also be shown as 816f010c200axxxx or 0x816f010c200axxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200bxxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the us...

Страница 805: ...ry May also be shown as 816f010c200cxxxx or 0x816f010c200cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200dxxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use...

Страница 806: ... error recovery May also be shown as 816f010c200exxxx or 0x816f010c200exxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200fxxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message i...

Страница 807: ...ecovery May also be shown as 816f010c2010xxxx or 0x816f010c2010xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2011xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for th...

Страница 808: ... error recovery May also be shown as 816f010c2012xxxx or 0x816f010c2012xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2013xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message i...

Страница 809: ...ecovery May also be shown as 816f010c2014xxxx or 0x816f010c2014xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2015xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for th...

Страница 810: ... error recovery May also be shown as 816f010c2016xxxx or 0x816f010c2016xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2017xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message i...

Страница 811: ...covery May also be shown as 816f010c2018xxxx or 0x816f010c2018xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2581xxxx Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is for t...

Страница 812: ... was Enabled May also be shown as 816f010d0400xxxx or 0x816f010d0400xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0401xxxx The Drive StorageVolumeElementName has been enabled Drive 1 This message is for the use case when an implementation ...

Страница 813: ...own as 816f010d0402xxxx or 0x816f010d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0403xxxx The Drive StorageVolumeElementName has been enabled Drive 3 This message is for the use case when an implementation has detected a Drive was En...

Страница 814: ...0404xxxx or 0x816f010d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0405xxxx The Drive StorageVolumeElementName has been enabled Drive 5 This message is for the use case when an implementation has detected a Drive was Enabled May also ...

Страница 815: ... Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0407xxxx The Drive StorageVolumeElementName has been enabled Drive 7 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0407xxxx or 0x816f010d04...

Страница 816: ...matically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0409xxxx The Drive StorageVolumeElementName has been enabled Drive 9 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0409xxxx or 0x816f010d0409xxxx Severity Info...

Страница 817: ... Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040bxxxx The Drive StorageVolumeElementName has been enabled Drive 11 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040bxxxx or 0x816f010d040bxxxx Severity Info Serviceable No Automatically no...

Страница 818: ...ive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040dxxxx The Drive StorageVolumeElementName has been enabled Drive 13 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040dxxxx or 0x816f010d040dxxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 819: ...e No action information only 816f010d 040fxxxx The Drive StorageVolumeElementName has been enabled Drive 15 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040fxxxx or 0x816f010d040fxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT...

Страница 820: ... This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0411xxxx or 0x816f010d0411xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0412xxxx The Drive StorageVolumeElementName has ...

Страница 821: ...ed May also be shown as 816f010d0413xxxx or 0x816f010d0413xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0414xxxx The Drive StorageVolumeElementName has been enabled Drive 20 This message is for the use case when an implementation has detec...

Страница 822: ...y also be shown as 816f010d0415xxxx or 0x816f010d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0416xxxx The Drive StorageVolumeElementName has been enabled Drive 22 This message is for the use case when an implementation has detected a...

Страница 823: ...xxx or 0x816f010d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0418xxxx The Drive StorageVolumeElementName has been enabled Drive 24 This message is for the use case when an implementation has detected a Drive was Enabled May also be s...

Страница 824: ...0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041axxxx The Drive StorageVolumeElementName has been enabled Drive 26 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0...

Страница 825: ...o Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041cxxxx The Drive StorageVolumeElementName has been enabled Drive 28 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041cxxxx or 0x816f010d041cxxxx Severi...

Страница 826: ...fy support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041exxxx The Drive StorageVolumeElementName has been enabled Drive 30 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041exxxx or 0x816f010d041exxxx Severity Info Serviceable ...

Страница 827: ... Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0420xxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 1 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0420xxxx or 0x816f010d0420xxxx Severity Info Serviceable No Automatically notify support...

Страница 828: ...P Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0422xxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 3 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0422xxxx or 0x816f010d0422xxxx Severity Info Serviceable No Automatically notify support No Alert Category C...

Страница 829: ...o action information only 816f010d 0424xxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 5 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0424xxxx or 0x816f010d0424xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix P...

Страница 830: ... This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0426xxxx or 0x816f010d0426xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0427xxxx The Drive StorageVolumeElementName has ...

Страница 831: ...nabled May also be shown as 816f010d0428xxxx or 0x816f010d0428xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0429xxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 10 This message is for the use case when an implementatio...

Страница 832: ...as Enabled May also be shown as 816f010d042axxxx or 0x816f010d042axxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 042bxxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 12 This message is for the use case when an implement...

Страница 833: ...also be shown as 816f010d042cxxxx or 0x816f010d042cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 042dxxxx The Drive StorageVolumeElementName has been enabled SDRAID Drive 14 This message is for the use case when an implementation has detec...

Страница 834: ...as 816f010d042exxxx or 0x816f010d042exxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010f 2201xxxx The System ComputerSystemElementName has recovered from a firmware hang Firmware Error This message is for the use case when an implementation has ...

Страница 835: ...ically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0225 User Response 1 Trained technician only Replace microprocessor n see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Repla...

Страница 836: ... sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 816f0125 0c01xxxx ManagedElementName detected as present Front Panel This message is for the use case when an implementation has detected a Managed El...

Страница 837: ...ical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response No action information only 816f0207 0302xxxx ProcessorElementName has Recovered from FRB1 BIST condition CPU 2 This message is for the use case when an implementation has detected a Processor Recovered FRB1 BIST condition May also be shown as 816f02070302xxxx or 0x816f02070302xxxx Severity Info Serviceable No Automatically ...

Страница 838: ... CIM Information Prefix PLAT ID 0045 User Response No action information only One of the CPUs 816f020d 0400xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected an Array Failure is no longer Predicted May also be shown as 816f020d0400xxxx or 0x816f020d0400xxxx Severity Info...

Страница 839: ... System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0402xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected an Array Failure is no longer Predicted May also be shown as 816f020d0402xxxx or 0x816f0...

Страница 840: ... support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0404xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected an Array Failure is no longer Predicted May also be shown as 8...

Страница 841: ...y support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0406xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected an Array Failure is no longer Predicted May also be shown as ...

Страница 842: ...omatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0408xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected an Array Failure is no longer Predicted May a...

Страница 843: ...able No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040axxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected an Array Failure is no longer Pre...

Страница 844: ...0bxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040cxxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected an Ar...

Страница 845: ...40dxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040exxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected an A...

Страница 846: ...d040fxxxx or 0x816f020d040fxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0410xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 16 This message is for the use case when an implemen...

Страница 847: ... 816f020d0411xxxx or 0x816f020d0411xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0412xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 18 This message is for the use case when an ...

Страница 848: ...also be shown as 816f020d0413xxxx or 0x816f020d0413xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0414xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 20 This message is for the u...

Страница 849: ...also be shown as 816f020d0415xxxx or 0x816f020d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0416xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 22 This message is for the u...

Страница 850: ... Predicted May also be shown as 816f020d0417xxxx or 0x816f020d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0418xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 24 This messa...

Страница 851: ...edicted May also be shown as 816f020d0419xxxx or 0x816f020d0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041axxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 26 This message ...

Страница 852: ...onger Predicted May also be shown as 816f020d041bxxxx or 0x816f020d041bxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041cxxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 28 This ...

Страница 853: ...edicted May also be shown as 816f020d041dxxxx or 0x816f020d041dxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041exxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 30 This message ...

Страница 854: ...er Predicted May also be shown as 816f020d041fxxxx or 0x816f020d041fxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0420xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 1 Th...

Страница 855: ...edicted May also be shown as 816f020d0421xxxx or 0x816f020d0421xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0422xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 3 This me...

Страница 856: ...onger Predicted May also be shown as 816f020d0423xxxx or 0x816f020d0423xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0424xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 5...

Страница 857: ...edicted May also be shown as 816f020d0425xxxx or 0x816f020d0425xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0426xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 7 This me...

Страница 858: ...onger Predicted May also be shown as 816f020d0427xxxx or 0x816f020d0427xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0428xxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 9...

Страница 859: ...edicted May also be shown as 816f020d0429xxxx or 0x816f020d0429xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 042axxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 11 This m...

Страница 860: ...onger Predicted May also be shown as 816f020d042bxxxx or 0x816f020d042bxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 042cxxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 1...

Страница 861: ...edicted May also be shown as 816f020d042dxxxx or 0x816f020d042dxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 042exxxx Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName SDRAID Drive 15 This m...

Страница 862: ...has returned to normal May also be shown as 816f03080a01xxxx or 0x816f03080a01xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0099 User Response No action information only 816f0308 0a02xxxx PowerSupplyElementName has returned to a Normal Input State Power Supply 2 This message is for the use case when an impl...

Страница 863: ...May also be shown as 816f030c2001xxxx or 0x816f030c2001xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2002xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 2 This message is for the use case when an ...

Страница 864: ...ery May also be shown as 816f030c2003xxxx or 0x816f030c2003xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2004xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 4 This message is for the use case when...

Страница 865: ...shown as 816f030c2005xxxx or 0x816f030c2005xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2006xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 6 This message is for the use case when an implementati...

Страница 866: ...shown as 816f030c2007xxxx or 0x816f030c2007xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2008xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 8 This message is for the use case when an implementati...

Страница 867: ...x or 0x816f030c2009xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200axxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 10 This message is for the use case when an implementation has detected a Memor...

Страница 868: ...16f030c200bxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200cxxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 12 This message is for the use case when an implementation has detected a Memory Scrub ...

Страница 869: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200exxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 14 This message is for the use case when an implementation has detected a Memory Scrub failure recovery ...

Страница 870: ... Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2010xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 16 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May als...

Страница 871: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2012xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 18 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2...

Страница 872: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2014xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 20 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2...

Страница 873: ...y support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2016xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 22 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2016xxxx or 0x816f...

Страница 874: ...No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2018xxxx Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 24 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2018xxxx or 0x816f030c2018xx...

Страница 875: ...ical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only One of the DIMMs 816f030d 0400xxxx Hot spare disabled for ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0400xxxx or 0x816f030d0400xxxx Severity Info Serviceable No Automatically n...

Страница 876: ...er Response No action information only 816f030d 0402xxxx Hot spare disabled for ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0402xxxx or 0x816f030d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PL...

Страница 877: ... is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0404xxxx or 0x816f030d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0405xxxx Hot spare disabled for ComputerSystemElementName Drive 5...

Страница 878: ...n Disabled May also be shown as 816f030d0406xxxx or 0x816f030d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0407xxxx Hot spare disabled for ComputerSystemElementName Drive 7 This message is for the use case when an implementation has detected a Hot ...

Страница 879: ...e shown as 816f030d0408xxxx or 0x816f030d0408xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0409xxxx Hot spare disabled for ComputerSystemElementName Drive 9 This message is for the use case when an implementation has detected a Hot Spare has been Disabl...

Страница 880: ...30d040axxxx or 0x816f030d040axxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040bxxxx Hot spare disabled for ComputerSystemElementName Drive 11 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be ...

Страница 881: ... Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040dxxxx Hot spare disabled for ComputerSystemElementName Drive 13 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d040dxxxx or 0x81...

Страница 882: ... Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 040fxxxx Hot spare disabled for ComputerSystemElementName Drive 15 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d040fxxxx or 0x816f030d040fxxxx...

Страница 883: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0411xxxx Hot spare disabled for ComputerSystemElementName Drive 17 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0411xxxx or 0x816f030d0411xxxx Severity Info Serviceable No...

Страница 884: ...o Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0413xxxx Hot spare disabled for ComputerSystemElementName Drive 19 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0413xxxx or 0x816f030d0413xxxx Severity Info Serviceable No Automatically no...

Страница 885: ... ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 0415xxxx Hot spare disabled for ComputerSystemElementName Drive 21 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0415xxxx or 0x816f030d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category System O...

Страница 886: ...r Response No action information only 816f030d 0417xxxx Hot spare disabled for ComputerSystemElementName Drive 23 This message is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0417xxxx or 0x816f030d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PL...

Страница 887: ... is for the use case when an implementation has detected a Hot Spare has been Disabled May also be shown as 816f030d0419xxxx or 0x816f030d0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041axxxx Hot spare disabled for ComputerSystemElementName Drive 2...

Страница 888: ...n Disabled May also be shown as 816f030d041bxxxx or 0x816f030d041bxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041cxxxx Hot spare disabled for ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected a Hot...

Страница 889: ...e shown as 816f030d041dxxxx or 0x816f030d041dxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f030d 041exxxx Hot spare disabled for ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected a Hot Spare has been Disab...

Страница 890: ...16f030d041fxxxx or 0x816f030d041fxxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0171 User Response No action information only 816f0313 1701xxxx System ComputerSystemElementName has recovered from an NMI NMI State This message is for the use case when an implementation has detected a Software NMI has been Rec...

Страница 891: ...xxxx or 0x816f040c2001xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2002xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that Memory has been Enabled May al...

Страница 892: ...16f040c2003xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2004xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown...

Страница 893: ...everity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2006xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2006x...

Страница 894: ...y Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2008xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2008xxxx or...

Страница 895: ... Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200axxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200axxxx or 0x816f040c200axxxx ...

Страница 896: ...No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200cxxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200cxxxx or 0x816f040c200cxxx...

Страница 897: ... notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200exxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200exxxx or 0x816f040c200exxxx Severity Info ...

Страница 898: ...pport No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2010xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2010xxxx or 0x816f040c2010xxxx Severity Info Serviceabl...

Страница 899: ...ystem Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2012xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2012xxxx or 0x816f040c2012xxxx Severity Info Serviceable No Automatically notify...

Страница 900: ...NMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2014xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2014xxxx or 0x816f040c2014xxxx Severity Info Serviceable No Automatically notify support No A...

Страница 901: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2016xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2016xxxx or 0x816f040c2016xxxx Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 902: ...IM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2018xxxx PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2018xxxx or 0x816f040c2018xxxx Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 903: ... Prefix PLAT ID 0130 User Response No action information only One of the DIMMs 816f0413 2582xxxx A PCI PERR recovery has occurred on system ComputerSystemElementName PCIs This message is for the use case when an implementation has detected a PCI PERR recovered May also be shown as 816f04132582xxxx or 0x816f04132582xxxx Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Страница 904: ...IM Information Prefix PLAT ID 0063 User Response No action information only 816f0507 0302xxxx ProcessorElementName has Recovered from a Configuration Mismatch CPU 2 This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05070302xxxx or 0x816f05070302xxxx Severity Info Serviceable No Automatically notify support No Aler...

Страница 905: ...063 User Response No action information only One of the CPUs 816f050c 2001xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2001xxxx or 0x816f050c2001xxxx Severity Info Serviceable No Automatically notif...

Страница 906: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2003xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2003xxxx or 0x816f050c2003xxxx Severity Info Serviceable No Auto...

Страница 907: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2005xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2005xxxx or 0x816f050c2005xxxx Severity Info Serviceable No Automaticall...

Страница 908: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2007xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2007xxxx or 0x816f050c2007xxxx Severity Info Serviceable No Auto...

Страница 909: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2009xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2009xxxx or 0x816f050c2009xxxx Severity Info Serviceable No Automaticall...

Страница 910: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 200bxxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200bxxxx or 0x816f050c200bxxxx Severity Info Serviceable No Aut...

Страница 911: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 200dxxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200dxxxx or 0x816f050c200dxxxx Severity Info Serviceable No Automatical...

Страница 912: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 200fxxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200fxxxx or 0x816f050c200fxxxx Severity Info Serviceable No Aut...

Страница 913: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2011xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2011xxxx or 0x816f050c2011xxxx Severity Info Serviceable No Automatical...

Страница 914: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2013xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2013xxxx or 0x816f050c2013xxxx Severity Info Serviceable No Aut...

Страница 915: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2015xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2015xxxx or 0x816f050c2015xxxx Severity Info Serviceable No Automatical...

Страница 916: ...IM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2017xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2017xxxx or 0x816f050c2017xxxx Severity Info Serviceable No Aut...

Страница 917: ...efix PLAT ID 0145 User Response No action information only 816f050c 2581xxxx Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2581xxxx or 0x816f050c2581xxxx Severity Info Serviceable No Automatically noti...

Страница 918: ...IM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0401xxxx Critical Array ComputerSystemElementName has deasserted Drive 1 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0401xxxx or 0x816f050d0401xxxx Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 919: ...No action information only 816f050d 0403xxxx Critical Array ComputerSystemElementName has deasserted Drive 3 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0403xxxx or 0x816f050d0403xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Info...

Страница 920: ...0d 0405xxxx Critical Array ComputerSystemElementName has deasserted Drive 5 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0405xxxx or 0x816f050d0405xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 921: ...xxx Critical Array ComputerSystemElementName has deasserted Drive 7 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0407xxxx or 0x816f050d0407xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 922: ...d 0409xxxx Critical Array ComputerSystemElementName has deasserted Drive 9 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0409xxxx or 0x816f050d0409xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User R...

Страница 923: ...xx Critical Array ComputerSystemElementName has deasserted Drive 11 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d040bxxxx or 0x816f050d040bxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 924: ...d 040dxxxx Critical Array ComputerSystemElementName has deasserted Drive 13 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d040dxxxx or 0x816f050d040dxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 925: ...xx Critical Array ComputerSystemElementName has deasserted Drive 15 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d040fxxxx or 0x816f050d040fxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 926: ...d 0411xxxx Critical Array ComputerSystemElementName has deasserted Drive 17 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0411xxxx or 0x816f050d0411xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 927: ...xx Critical Array ComputerSystemElementName has deasserted Drive 19 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0413xxxx or 0x816f050d0413xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 928: ...d 0415xxxx Critical Array ComputerSystemElementName has deasserted Drive 21 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0415xxxx or 0x816f050d0415xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 929: ...xx Critical Array ComputerSystemElementName has deasserted Drive 23 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0417xxxx or 0x816f050d0417xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 930: ...d 0419xxxx Critical Array ComputerSystemElementName has deasserted Drive 25 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0419xxxx or 0x816f050d0419xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 931: ...xx Critical Array ComputerSystemElementName has deasserted Drive 27 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d041bxxxx or 0x816f050d041bxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response...

Страница 932: ...d 041dxxxx Critical Array ComputerSystemElementName has deasserted Drive 29 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d041dxxxx or 0x816f050d041dxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User ...

Страница 933: ...Critical Array ComputerSystemElementName has deasserted Drive 31 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d041fxxxx or 0x816f050d041fxxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response No...

Страница 934: ...nse No action information only 816f050d 0421xxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 2 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0421xxxx or 0x816f050d0421xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID...

Страница 935: ...mation Prefix PLAT ID 0175 User Response No action information only 816f050d 0423xxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 4 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0423xxxx or 0x816f050d0423xxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 936: ...IM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0425xxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 6 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0425xxxx or 0x816f050d0425xxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 937: ...mation Prefix PLAT ID 0175 User Response No action information only 816f050d 0427xxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 8 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0427xxxx or 0x816f050d0427xxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 938: ...IM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0429xxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 10 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d0429xxxx or 0x816f050d0429xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 939: ...mation Prefix PLAT ID 0175 User Response No action information only 816f050d 042bxxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 12 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d042bxxxx or 0x816f050d042bxxxx Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 940: ...IM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 042dxxxx Critical Array ComputerSystemElementName has deasserted SDRAID Drive 14 This message is for the use case when an implementation has detected that an Critical Array has deasserted May also be shown as 816f050d042dxxxx or 0x816f050d042dxxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 941: ...formation Prefix PLAT ID 0175 User Response No action information only 816f0607 0301xxxx An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted CPU 1 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06070301xxxx or 0x816f06070301xxxx Severity Info Serviceable No Automatically notify support No Alert...

Страница 942: ...ation Prefix PLAT ID 0817 User Response No action information only 816f0607 2584xxxx An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted All CPUs This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06072584xxxx or 0x816f06072584xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 943: ...ation only 816f060d 0400xxxx Array in system ComputerSystemElementName has been restored Drive 0 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0400xxxx or 0x816f060d0400xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Pref...

Страница 944: ...402xxxx Array in system ComputerSystemElementName has been restored Drive 2 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0402xxxx or 0x816f060d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User ...

Страница 945: ...Array in system ComputerSystemElementName has been restored Drive 4 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0404xxxx or 0x816f060d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response...

Страница 946: ...406xxxx Array in system ComputerSystemElementName has been restored Drive 6 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0406xxxx or 0x816f060d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User ...

Страница 947: ...Array in system ComputerSystemElementName has been restored Drive 8 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0408xxxx or 0x816f060d0408xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response...

Страница 948: ...onse No action information only 816f060d 040axxxx Array in system ComputerSystemElementName has been restored Drive 10 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d040axxxx or 0x816f060d040axxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID ...

Страница 949: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 040cxxxx Array in system ComputerSystemElementName has been restored Drive 12 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d040cxxxx or 0x816f060d040cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 950: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040exxxx Array in system ComputerSystemElementName has been restored Drive 14 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d040exxxx or 0x816f060d040exxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 951: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0410xxxx Array in system ComputerSystemElementName has been restored Drive 16 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0410xxxx or 0x816f060d0410xxxx Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 952: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0412xxxx Array in system ComputerSystemElementName has been restored Drive 18 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0412xxxx or 0x816f060d0412xxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 953: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0414xxxx Array in system ComputerSystemElementName has been restored Drive 20 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0414xxxx or 0x816f060d0414xxxx Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 954: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0416xxxx Array in system ComputerSystemElementName has been restored Drive 22 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0416xxxx or 0x816f060d0416xxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 955: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0418xxxx Array in system ComputerSystemElementName has been restored Drive 24 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0418xxxx or 0x816f060d0418xxxx Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 956: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041axxxx Array in system ComputerSystemElementName has been restored Drive 26 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041axxxx or 0x816f060d041axxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 957: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 041cxxxx Array in system ComputerSystemElementName has been restored Drive 28 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041cxxxx or 0x816f060d041cxxxx Severity Info Serviceable No Automatically notify support No Alert Category Cr...

Страница 958: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041exxxx Array in system ComputerSystemElementName has been restored Drive 30 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041exxxx or 0x816f060d041exxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 959: ...ion Prefix PLAT ID 0177 User Response No action information only 816f060d 0420xxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 1 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0420xxxx or 0x816f060d0420xxxx Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 960: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0422xxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 3 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0422xxxx or 0x816f060d0422xxxx Severity Info Serviceable No Automatically notify support No Ale...

Страница 961: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0424xxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 5 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0424xxxx or 0x816f060d0424xxxx Severity Info Serviceable No Automatically notify support No Alert Categ...

Страница 962: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0426xxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 7 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0426xxxx or 0x816f060d0426xxxx Severity Info Serviceable No Automatically notify support No Ale...

Страница 963: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0428xxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 9 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0428xxxx or 0x816f060d0428xxxx Severity Info Serviceable No Automatically notify support No Alert Categ...

Страница 964: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 042axxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 11 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d042axxxx or 0x816f060d042axxxx Severity Info Serviceable No Automatically notify support No Al...

Страница 965: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 042cxxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 13 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d042cxxxx or 0x816f060d042cxxxx Severity Info Serviceable No Automatically notify support No Alert Cate...

Страница 966: ...IM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 042exxxx Array in system ComputerSystemElementName has been restored SDRAID Drive 15 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d042exxxx or 0x816f060d042exxxx Severity Info Serviceable No Automatically notify support No Al...

Страница 967: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2002xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 2 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2002xxxx or 0x816f070c2002xxxx Severity Info Serviceable No Auto...

Страница 968: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2004xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 4 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2004xxxx or 0x816f070c2004xxxx Severity Info Serviceable...

Страница 969: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2006xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 6 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2006xxxx or 0x816f070c2006xxxx Severity Info Serviceable No Auto...

Страница 970: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2008xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 8 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2008xxxx or 0x816f070c2008xxxx Severity Info Serviceable...

Страница 971: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200axxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 10 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200axxxx or 0x816f070c200axxxx Severity Info Serviceable No Aut...

Страница 972: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 200cxxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 12 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200cxxxx or 0x816f070c200cxxxx Severity Info Serviceabl...

Страница 973: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200exxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 14 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200exxxx or 0x816f070c200exxxx Severity Info Serviceable No Aut...

Страница 974: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2010xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 16 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2010xxxx or 0x816f070c2010xxxx Severity Info Serviceabl...

Страница 975: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2012xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 18 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2012xxxx or 0x816f070c2012xxxx Severity Info Serviceable No Aut...

Страница 976: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2014xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 20 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2014xxxx or 0x816f070c2014xxxx Severity Info Serviceabl...

Страница 977: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2016xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 22 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2016xxxx or 0x816f070c2016xxxx Severity Info Serviceable No Aut...

Страница 978: ...IM Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2018xxxx Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 24 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2018xxxx or 0x816f070c2018xxxx Severity Info Serviceabl...

Страница 979: ...ap ID 41 CIM Information Prefix PLAT ID 0127 User Response No action information only One of the DIMMs 816f070d 0400xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0400xxxx or 0x816f070d0400xxxx Severity Info Serviceable No Automatically...

Страница 980: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0402xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0402xxxx or 0x816f070d0402xxxx Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 981: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0404xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0404xxxx or 0x816f070d0404xxxx Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 982: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0406xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0406xxxx or 0x816f070d0406xxxx Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 983: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0408xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0408xxxx or 0x816f070d0408xxxx Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 984: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 040axxxx Rebuild completed for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040axxxx or 0x816f070d040axxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 985: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040cxxxx Rebuild completed for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040cxxxx or 0x816f070d040cxxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 986: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 040exxxx Rebuild completed for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040exxxx or 0x816f070d040exxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 987: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0410xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0410xxxx or 0x816f070d0410xxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 988: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0412xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0412xxxx or 0x816f070d0412xxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 989: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0414xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0414xxxx or 0x816f070d0414xxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 990: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0416xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0416xxxx or 0x816f070d0416xxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 991: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0418xxxx Rebuild completed for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0418xxxx or 0x816f070d0418xxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 992: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 041axxxx Rebuild completed for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041axxxx or 0x816f070d041axxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 993: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041cxxxx Rebuild completed for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041cxxxx or 0x816f070d041cxxxx Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 994: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 041exxxx Rebuild completed for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041exxxx or 0x816f070d041exxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 995: ...ion Prefix PLAT ID 0179 User Response No action information only 816f070d 0420xxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 1 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0420xxxx or 0x816f070d0420xxxx Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 996: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0422xxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 3 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0422xxxx or 0x816f070d0422xxxx Severity Info Serviceable No Automatically notify support No A...

Страница 997: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0424xxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 5 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0424xxxx or 0x816f070d0424xxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 998: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0426xxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 7 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0426xxxx or 0x816f070d0426xxxx Severity Info Serviceable No Automatically notify support No A...

Страница 999: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0428xxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 9 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0428xxxx or 0x816f070d0428xxxx Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 1000: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 042axxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 11 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d042axxxx or 0x816f070d042axxxx Severity Info Serviceable No Automatically notify support No ...

Страница 1001: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 042cxxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 13 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d042cxxxx or 0x816f070d042cxxxx Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 1002: ...IM Information Prefix PLAT ID 0179 User Response No action information only 816f070d 042exxxx Rebuild completed for Array in system ComputerSystemElementName SDRAID Drive 15 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d042exxxx or 0x816f070d042exxxx Severity Info Serviceable No Automatically notify support No ...

Страница 1003: ...Response No action information only 816f0807 0302xxxx ProcessorElementName has been Enabled CPU 2 This message is for the use case when an implementation has detected a Processor has been Enabled May also be shown as 816f08070302xxxx or 0x816f08070302xxxx Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User R...

Страница 1004: ...emElementName has recovered from an Uncorrectable Bus Error DIMMs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132581xxxx or 0x816f08132581xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0241 U...

Страница 1005: ...information only 816f0813 2584xxxx System ComputerSystemElementName has recovered from an Uncorrectable Bus Error CPUs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132584xxxx or 0x816f08132584xxxx Severity Info Serviceable No Automatically notify support No Alert Category Critical Other ...

Страница 1006: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2002xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 2 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2002xxxx or 0x816f090c2002xxxx Severity Info Serviceable No Automatically notify support No...

Страница 1007: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2004xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 4 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2004xxxx or 0x816f090c2004xxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1008: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2006xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 6 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2006xxxx or 0x816f090c2006xxxx Severity Info Serviceable No Automatically notify support No...

Страница 1009: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2008xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 8 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2008xxxx or 0x816f090c2008xxxx Severity Info Serviceable No Automatically notify support No Alert C...

Страница 1010: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 200axxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 10 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200axxxx or 0x816f090c200axxxx Severity Info Serviceable No Automatically notify support N...

Страница 1011: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 200cxxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 12 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200cxxxx or 0x816f090c200cxxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1012: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 200exxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 14 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200exxxx or 0x816f090c200exxxx Severity Info Serviceable No Automatically notify support N...

Страница 1013: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2010xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 16 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2010xxxx or 0x816f090c2010xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1014: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2012xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 18 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2012xxxx or 0x816f090c2012xxxx Severity Info Serviceable No Automatically notify support N...

Страница 1015: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2014xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 20 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2014xxxx or 0x816f090c2014xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1016: ...IM Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2016xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 22 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2016xxxx or 0x816f090c2016xxxx Severity Info Serviceable No Automatically notify support N...

Страница 1017: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2018xxxx PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 24 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2018xxxx or 0x816f090c2018xxxx Severity Info Serviceable No Automatically notify support No Alert ...

Страница 1018: ...IM Information Prefix PLAT ID 0039 User Response No action information only 816f0a07 0302xxxx The Processor ProcessorElementName is no longer operating in a Degraded State CPU 2 This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state May also be shown as 816f0a070302xxxx or 0x816f0a070302xxxx Severity Info Serviceable No Automatic...

Страница 1019: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2002xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2002xxxx or 0x816f0a0c2002xxxx Seve...

Страница 1020: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2004xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2004xxxx or 0x816f0a0c2004x...

Страница 1021: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2006xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2006xxxx or 0x816f0a0c2006xxxx Seve...

Страница 1022: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2008xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2008xxxx or 0x816f0a0c2008x...

Страница 1023: ...ation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200axxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200axxxx or 0x816f0a0c200axxxx Seve...

Страница 1024: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200cxxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200cxxxx or 0x816f0a0c200c...

Страница 1025: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200exxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200exxxx or 0x816f0a0c200exxxx Sev...

Страница 1026: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2010xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2010xxxx or 0x816f0a0c2010...

Страница 1027: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2012xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2012xxxx or 0x816f0a0c2012xxxx Sev...

Страница 1028: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2014xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2014xxxx or 0x816f0a0c2014...

Страница 1029: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2016xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2016xxxx or 0x816f0a0c2016xxxx Sev...

Страница 1030: ...IM Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2018xxxx An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2018xxxx or 0x816f0a0c2018...

Страница 1031: ...ink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 816f0a13 0302xxxx System ComputerSystemElementName has recovered from a Fatal Bus Error CPU 2 PECI This mes...

Страница 1032: ... heat sink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 1016 System x3500 M5 Installation and Service Guide ...

Страница 1033: ...ser action or a change of states that is normal behavior Warning A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response Indicate the ...

Страница 1034: ...lowing steps 1 Verify that the processor is a valid option that is listed as a Server Proven device for this system If not remove the Processor and install one listed on the Server Proven website 2 Verify that matching processors are installed in the correct processor sockets Correct any mismatch found 3 Check the Lenovo support site for an applicable service bulletin or firmware update that appli...

Страница 1035: ...on Severity Error User Response Complete the following steps 1 Verify that matching processors are installed in the correct processor sockets Correct any mismatch found 2 Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Trained technician only Replace the system board I 1800F A processor family mismatch has been detected for...

Страница 1036: ... any applicable service bulletin or UEFI or adapter firmware update that applies to this error NOTE It may be necessary to disable unused option ROMs from UEFI F1 setup or ToolsCenter Suite CLI or using adapter manufacturer utilities so that adapter firmware can be updated 3 Move the adapter to a different slot If a slot is not available or error recurs replace the adapter 4 If the adapter was mov...

Страница 1037: ...Event Log and Restart Server I 3818001 The firmware image capsule signature for the currently booted flash bank is invalid Current Bank CRTM Capsule Update Signature Invalid Explanation Severity Info User Response Complete the following steps 1 Reboot the system Will come up on backup UEFI image Update the primary UEFI image 2 If error does not persist no additional recovery action is required 3 I...

Страница 1038: ...initialized TPMINIT Fail to initialize TPM chip Explanation Severity Info User Response Complete the following steps 1 Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this error 2 Reboot the system 3 If the error continues replace the system board assembly see Removing the system board assembly and Installing the system board assembly I 3868000 I...

Страница 1039: ... Local Sales Representative or Authorized Business Partner to order qualified memory to replace the unqualified DIMM s 5 After you install qualified memory and power up the server check to make sure this informational event is not logged again I 58015 Memory spare copy initiated Spare Copy Started Explanation Severity Info User Response Complete the following steps 1 Information only no action is ...

Страница 1040: ... CATERR IERR has asserted Explanation Severity Error User Response Complete the following steps 1 Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to this Processor error 2 Trained service technician only If there are multiple Processor s swap Processor s to move affected Processor to another Processor socket and retry If problem follows the affecte...

Страница 1041: ...ce is not recognized reconfiguring slot to Gen1 or Gen2 may be required Gen1 Gen2 settings can be configured via F1 Setup System Settings Devices and I O Ports PCIe Gen1 Gen2 Gen3 Speed Selection or the ToolsCenter Suite CLI Utility 3 If problem persists then remove Adapter Card If system reboots successfully without the adapter replace that card 4 Trained Service technician only Replace the syste...

Страница 1042: ...e the UEFI image 3 Trained service technician only Replace the system board S 3028002 Boot permission timeout detected Boot Permission Negotiation Timeout Explanation Severity Error User Response Complete the following steps 1 Check CMM IMM logs for communication errors and resolve 2 Reseat the system 3 If problem persists contact support S 3030007 A firmware fault has been detected in the UEFI im...

Страница 1043: ...e system has booted with default UEFI settings POST failure has occurred System booted with default settings Explanation Severity Error User Response Complete the following steps 1 This event resets UEFI to the default settings for the next boot If successful the Setup Utility is displayed The original UEFI settings are still present 2 If you did not intentionally trigger the reboots check logs fo...

Страница 1044: ...ed System halted Explanation Severity Error User Response Complete the following steps 1 Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error 2 Update the UEFI image 3 Replace the system board S 3108007 The default system settings have been restored System Configuration Restored to Defaults Explanation Severity Error User Response Complete the ...

Страница 1045: ...lot arg1 on rank arg2 An uncorrectable memory error was detected on processor arg3 channel arg4 The failing DIMM within the channel could not be determined An uncorrectable memory error has been detected Fatal Memory Error Occurred Explanation Severity Error User Response Complete the following steps 1 Check Lenovo support site for an applicable service bulletin or firmware update that applies to ...

Страница 1046: ...sabled by other errors or actions could cause this event 2 Verify that the DIMMs are installed in the correct population sequence 3 Disable memory mirroring and sparing If this action eliminates the mismatch check the Lenovo Support site for information related to this problem 4 Update UEFI firmware 5 Replace the DIMM 6 Replace the processor S 51009 No system memory has been detected No Memory Det...

Страница 1047: ...r and inspect Processor socket pins for damaged or mis aligned pins If damage is found or this is an upgrade Processor replace the system board If there are multiple Processor s swap Processor s to move affected Processor to another Processor socket and retry If problem follows the affected Processor or there is only one Processor replace the affected Processor 7 If problem stays with the original...

Страница 1048: ...in the system has failed the BIST Processor Self Test Failure Detected Explanation Severity Error User Response Complete the following steps 1 If the processor or firmware was just updated check the Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error 2 Trained service technician only If there are multiple Processor s swap Processor s to mo...

Страница 1049: ...vo support site for an applicable service bulletin or firmware update that applies to this error 4 Trained service technician only Replace the system board W 3058009 DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 DRIVER HEALTH PROTOCOL Missing Configuration Requires Change Settings From F1 Explanation Severity Warning User Response Complete the following steps 1 Go t...

Страница 1050: ...Required Controller DRIVER HEALTH PROTOCOL Reports System Shutdown Required Controller Explanation Severity Warning User Response Complete the following steps 1 No action required The system will reboot at the end of POST 2 If the problem persists switch to the backup UEFI image or update the current UEFI image 3 Replace the system board W 305800D DRIVER HEALTH PROTOCOL Disconnect Controller Faile...

Страница 1051: ... Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this error 4 Update the UEFI Firmware 5 Trained service technician only Replace the system board W 3808002 An error occurred while saving UEFI settings to the IMM Error Updating System Configuration to IMM Explanation Severity Warning User Response Complete the following steps 1 Use the Setup Utili...

Страница 1052: ...M flash driver could not successfully flash the staging area The update was aborted CRTM Update Aborted Explanation Severity Warning User Response Complete the following steps 1 Continue booting the system If system does not reset manually reset the system 2 If the error is not reported on the subsequent boot no additional recovery action is required 3 If the event persists continue booting system...

Страница 1053: ... Info User Response Complete the following steps 1 If the DIMM was disabled because of a memory fault follow the procedure for that event 2 If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit re enable the DIMM through the Setup utility or the ToolsCenter Suite CLI 3 If the problem persists Power cycle the compute node from the management console 4 Reset the IMM to ...

Страница 1054: ... channels one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing paring modes If problem follows a moved DIMM to a different memory channel replace that DIMM 6 Trained service technician only Remove affected Processor and inspect Processor socket pins for damaged or mis aligned pins If damage is foun...

Страница 1055: ...r error LED is lit resolve the failure 2 Make sure that the DIMM connectors are correctly populated for sparing mode according to the service information for this product W 68002 A CMOS battery error has been detected CMOS Battery Fault Explanation Severity Error User Response Complete the following steps 1 If the system was recently installed moved or serviced make sure the battery is properly se...

Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...

Страница 1057: ...ult when you run the DSA Broadcom network test 405 000 000 BRCM TestControlRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 001 000 BRCM TestMIIRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify s...

Страница 1058: ...IMM 405 003 000 BRCM TestInternalMemory Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 004 000 BRCM TestInterrupt Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No 1042 System x3500 M5 Installation and ...

Страница 1059: ...o Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 006 000 BRCM TestLoopbackPhysical Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 007 000 BRCM TestLEDs Test Passed The test passed Recoverable No Appendix C DSA diagnosti...

Страница 1060: ...le No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 801 000 BRCM TestMIIRegisters Test Aborted The MII register test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 1044 Sy...

Страница 1061: ...3 000 BRCM TestInternalMemory Test Aborted The internal memory test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 804 000 BRCM TestInterrupt Test Aborted The interrupt test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Appe...

Страница 1062: ...vo Support website Latest level of DSA Latest level of BMC IMM 405 806 000 BRCM TestLoopbackPhysical Test Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 405 807 000 BRCM TestLEDs Test Aborted Verification of status LEDs was can...

Страница 1063: ...t firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 40...

Страница 1064: ...ected while testing non volatile RAM Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshoot...

Страница 1065: ...TestInterrupt Test Failed A failure was detected while testing interrupts Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If ...

Страница 1066: ...vel of BMC IMM 405 906 000 BRCM TestLoopbackPhysical Test Failed A failure was detected during the loopback test at the physical layer Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the F...

Страница 1067: ...onent 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA Brocade test results The following messages can result when you run the Brocade test Test results for the DSA Brocade test The following messages can result wh...

Страница 1068: ...elated links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 002 000 Brocade SerdesLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 003 000 Brocade PCILoopbackTest Passed The test passed Recoverable No 1052 System x3500 M5 Insta...

Страница 1069: ...rable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 005 000 Brocade SerdesEthLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic...

Страница 1070: ... 218 800 000 Brocade MemoryTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 801 000 Brocade ExternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No 1054 System x3500 M5 Install...

Страница 1071: ...ted links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 803 000 Brocade PCILoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 804 000 Brocade ExternalEthLoopbackTest Aborted The test was canceled Recoverable No Appendix...

Страница 1072: ...No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 806 000 Brocade InternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 1056 System x3500 M5 ...

Страница 1073: ...rt representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 901 000 Brocade ExternalLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at prope...

Страница 1074: ...the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 903 000 Brocade PCILoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the...

Страница 1075: ... cable 2 Rerun the test 3 Verify whether the firmware is at proper level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 218 905 000 Brocade SerdesEthLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatical...

Страница 1076: ...ete the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA checkpoint panel test results The following messages can result when you run the checkpoint panel test Test results for the DSA check...

Страница 1077: ... No User Response Complete the following steps 1 Inspect and reseat operator information panel cable at both ends 2 Verify that the Baseboard Management Controller BMC is working 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest lev...

Страница 1078: ...ymptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA CPU stress test results The following messages can result when you run the CPU stress test Test results for the DSA CPU stress test The following messages can result when you run the DSA CPU stress test 089 000 000 CPU Stress Test P...

Страница 1079: ...ion for this component The latest level firmware for this component can be found in reference to this system type at the IBM Support website 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Relate...

Страница 1080: ...ubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 089 803 000 CPU Stress Test Aborted CPU Stress Test Aborted Memory size is insufficient to run the test At least 1GB is required Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related li...

Страница 1081: ...found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA L...

Страница 1082: ...opBackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 516 002 000 ELXUCNA ELXUCNA NIC LED Beacon Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links 1066 System x3500 M5 Installation and Service ...

Страница 1083: ...e Latest level of DSA Latest level of BMC IMM 516 801 000 ELXUCNA NIC PHY LoopBackTest Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 516 802 000 ELXUCNA ELXUCNA NIC LED Beacon Test Aborted Verification of status LEDs was cance...

Страница 1084: ...ecessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 516 901 000 ELXUCNA NIC PHY LoopBac...

Страница 1085: ...ble No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and...

Страница 1086: ... notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Make sure that DSA and BIOS uEFI are at the latest level 4 If the problem remains contact your technical service representative Related links Lenovo Support website Latest level of DSA Late...

Страница 1087: ...st level of BMC IMM 401 901 001 EXA Port Ping Test Failed EXA Port Ping Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Check scalability cables for loose connections...

Страница 1088: ...upport No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 217 800 000 HDD Test Aborted HDD Test Aborted The test was canceled Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify that Hard drive supports self test and self test logging 4 If the ...

Страница 1089: ...e is at the latest level 4 Rerun the test 5 If the problem remains contact your technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA Intel network test results The following messages can result when you run the Intel network test Test results for the DSA Intel network test The following messages can result when you run the DSA Intel ...

Страница 1090: ...ble No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 406 002 000 IANet FIFO Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 406 003 000 IANet Interrupts Test Passed 1074 System x3500 M5 Installat...

Страница 1091: ...pback Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 406 800 000 IANet Registers Test Aborted Registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Appendix C DSA diagnostic test results 1075 ...

Страница 1092: ...Support website Latest level of DSA Latest level of BMC IMM 406 802 000 IANet FIFO Test Aborted FIFO test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 406 803 000 IANet Interrupts Test Aborted Interrupt test was canceled Recoverable No Severity Warning 1076 System x3500 M...

Страница 1093: ...et Registers Test Failed A failure was detected during the Registers test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If ...

Страница 1094: ...t 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 406 902 000 IANet FIFO Test Failed A failure was detected during the FIFO test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Respo...

Страница 1095: ...und in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log If the ethernet device is sharing interrupts if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the device 4 Rerun the test 5 If failure remains refer to Troubleshooting b...

Страница 1096: ...or the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA LSI hard drive test results The following messages can result when you run the LSI hard drive test Test results for the DSA LSI hard drive test The following messages can result when you run the DSA LSI hard drive test 407 000 000 LSIESG DiskDefaultDiagnostic Test Passed The test pass...

Страница 1097: ...Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA Mellanox adapter test results The fo...

Страница 1098: ...ed links Lenovo Support website Latest level of DSA Latest level of BMC IMM 408 001 000 MLNX MLNX_DiagnosticTestIBPort Test Passed Port Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 408 800 000 MLNX MLNX_DiagnosticTestEthernetPort Test Aborted Port Test was canceled Recoverab...

Страница 1099: ... DSA Latest level of BMC IMM 408 900 000 MLNX MLNX_DiagnosticTestEthernetPort Test Failed Port Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that the physical link of the port under test in the active state 2 If these condition was met but the test keeps failing the port s adapter might be faulty 3 T...

Страница 1100: ... was met but the test keeps failing the port s adapter might be faulty 3 Try replacing the adapter and repeating the test Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA memory isolation test results The following messages can result when you run the memory isolation test Test results for the DSA memory isolation test The following messages can result when you ...

Страница 1101: ...tify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 000 002 Standalone Memory Test Passed Quick Full Memory Test CPU 2 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 000 003 Standalone Memory Test Passed Quick Full Memory Test CP...

Страница 1102: ...vent Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 811 000 Standalone Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after ...

Страница 1103: ... notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo...

Страница 1104: ...te SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power ...

Страница 1105: ...e Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for...

Страница 1106: ...of DSA Latest level of BMC IMM 201 812 003 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn ...

Страница 1107: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 813 001 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test a...

Страница 1108: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 813 003 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notif...

Страница 1109: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1110: ...ing feature for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1111: ... Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1112: ...SA Latest level of BMC IMM 201 815 002 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 ...

Страница 1113: ...IOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 816 000 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after...

Страница 1114: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 816 002 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify sup...

Страница 1115: ...ponse Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest lev...

Страница 1116: ...ate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1117: ... Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat D...

Страница 1118: ...est level of BMC IMM 201 819 001 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representat...

Страница 1119: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 819 003 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try th...

Страница 1120: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 820 001 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No Use...

Страница 1121: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1122: ...ange MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1123: ...ange MTRR registers are larger than fixed range MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1124: ...t level of DSA Latest level of BMC IMM 201 822 000 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the ...

Страница 1125: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 822 002 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the pro...

Страница 1126: ...t for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 824 000 Standalone Memory Test Aborted Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatic...

Страница 1127: ...plete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA...

Страница 1128: ...Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM ...

Страница 1129: ...Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off th...

Страница 1130: ...enovo Support website Latest level of DSA Latest level of BMC IMM 201 826 003 Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If t...

Страница 1131: ...ure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 827 001 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions...

Страница 1132: ...ff the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 827 003 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serv...

Страница 1133: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1134: ...trol MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1135: ...set Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1136: ...st level of BMC IMM 201 845 002 Standalone Memory Test Aborted Chipset Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representat...

Страница 1137: ...ke sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 859 000 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Страница 1138: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 859 002 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete ...

Страница 1139: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1140: ...o OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1141: ...01 860 003 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1142: ...atest level of DSA Latest level of BMC IMM 201 861 001 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the syst...

Страница 1143: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 861 003 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rem...

Страница 1144: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 862 001 Standalone Memory Test Aborted No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complet...

Страница 1145: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1146: ...y in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1147: ...andalone Memory Test Aborted No IBMERROR key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1148: ...test level of DSA Latest level of BMC IMM 201 864 000 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the sys...

Страница 1149: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 864 002 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem r...

Страница 1150: ...m and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 865 000 Standalone Memory Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Com...

Страница 1151: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1152: ...structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make su...

Страница 1153: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1154: ...SA Latest level of BMC IMM 201 866 003 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 T...

Страница 1155: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 867 001 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the pro...

Страница 1156: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 867 003 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Co...

Страница 1157: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1158: ...MemoryMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1159: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1160: ...SA Latest level of BMC IMM 201 869 002 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 T...

Страница 1161: ...t DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 870 000 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action ...

Страница 1162: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 870 002 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Co...

Страница 1163: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1164: ...compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1165: ...t Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Re...

Страница 1166: ...vel of BMC IMM 201 877 001 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repres...

Страница 1167: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 877 003 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time...

Страница 1168: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 878 001 Standalone Memory Test Aborted Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Recoverable No Severity Warning Serviceable ...

Страница 1169: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA ...

Страница 1170: ...emory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power...

Страница 1171: ...RR register manipulation Can not write to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1172: ...l of DSA Latest level of BMC IMM 201 886 000 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn o...

Страница 1173: ...OS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 886 002 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action...

Страница 1174: ...ntact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 899 000 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Wa...

Страница 1175: ...01 899 002 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 201 899 003 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support...

Страница 1176: ... power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related lin...

Страница 1177: ...IMM 201 901 002 Standalone Memory Test Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power...

Страница 1178: ...atest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA memory stress test results The follo...

Страница 1179: ...un the test again 4 If the system has stopped responding turn off and restart the system 5 Check the system firmware level and upgrade if necessary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level...

Страница 1180: ...SA Latest level of BMC IMM 202 901 000 MemStr Test Failed Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Execute the standard DSA memory diagnostics to validate all memory 2 Make sure that the DSA Diagnostic code is at the latest level 3 Turn off the system and disconnect it from power 4 Reseat the memory cards...

Страница 1181: ...ed by checking the Available System Memory in the Resource Utilization section of the DSA Diagnostic Event log 2 If necessary access the Configuration Setup Utility program by pressing F1 during system boot and enable all memory 3 Make sure that the DSA Diagnostic code is at the latest level 4 Run the test again 5 Execute the standard DSA memory diagnostics to validate all memory 6 If the failure ...

Страница 1182: ...rt website Latest level of DSA Latest level of BMC IMM 409 003 000 Nvidia DiagnosticServiceProvider Bandwidth Test Passed Nvidia GPU Bandwidth test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 004 000 Nvidia DiagnosticServiceProvider Query Test Passed Nvidia GPU Query test pa...

Страница 1183: ...upport No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 006 000 Nvidia DiagnosticServiceProvider Binomial Test Passed Nvidia GPU Binomial test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 800 000 NVIDIA User Diagnostic Test Aborted NVIDI...

Страница 1184: ... canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 804 000 Nvidia DiagnosticServiceProvider Query Test Aborted Nvidia GPU Query test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of...

Страница 1185: ...A Latest level of BMC IMM 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Nvidia GPU Binomial test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 900 000 NVIDIA User Diagnostic Test Failed NVIDIA User Diagnostic Test Failed Recoverable No Severity Eve...

Страница 1186: ...ServiceProvider Bandwidth Test Failed Nvidia GPU Bandwidth Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run...

Страница 1187: ...ative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 409 905 000 Nvidia DiagnosticServiceProvider Matrix Test Failed Nvidia GPU Matrix Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle t...

Страница 1188: ...idia smi q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same GPU on system that is known to be working A variety of system issues can cause diagnostic failure 5 If the problem remains contact your IBM technical support representative Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA optical drive test results The...

Страница 1189: ...atest level 2 Run the test again 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 Check system firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 6 Run the test again Related link...

Страница 1190: ...n the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 215 803 000 Optical Drive Test Failed Optical Drive Test Failed Disk may be in use by the operating system Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Wait for the s...

Страница 1191: ...Run the test again 5 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 215 901 000 Optical Drive Test Aborted Optical Drive Test Aborted Drive media is not detected Recoverable No Severity Warning Serviceable Yes Automatically notify supp...

Страница 1192: ... wait for 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest le...

Страница 1193: ...remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM DSA system management test results The following messages can result when you run the system management test Test results for the DSA system management test The following messages can result when you...

Страница 1194: ...f DSA Latest level of BMC IMM 166 802 001 IMM I2C Test Aborted Test cannot be completed for unknown reason Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BM...

Страница 1195: ...evel of BMC IMM 166 804 001 IMM I2C Test Aborted Invalid Command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related link...

Страница 1196: ...806 001 IMM I2C Test Aborted Timeout while processing command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links L...

Страница 1197: ...ted Reservation Canceled or Invalid Reservation ID Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Suppo...

Страница 1198: ...alid Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of...

Страница 1199: ...lly notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 813 001 IMM I2C Test Aborted Cannot return number ...

Страница 1200: ...action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 815 001 IMM I2C Test Aborted Invalid data field in Request Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perfo...

Страница 1201: ...Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 817 001 IMM I2C Test Aborted Command response could not be provided Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each ac...

Страница 1202: ...re at the latest level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 819 001 IMM I2C Test Aborted Command response could not be provided SDR Repository in update mode Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system...

Страница 1203: ...test level Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 821 001 IMM I2C Test Aborted Command response could not be provided BMC initialization in progress Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and discon...

Страница 1204: ... Latest level of DSA Latest level of BMC IMM 166 823 001 IMM I2C Test Aborted Cannot execute command Insufficient privilege level Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Ma...

Страница 1205: ...est Failed IMM Indicates failure in RTMM bus BUS 0 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level 3 Run the test again 4 If fa...

Страница 1206: ... Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 905 001 IMM I2C Test Failed IMM Indicates failure in PSU 1 bus BUS 4 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect ...

Страница 1207: ...gain 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 166 908 001 IMM I2C Test Failed IMM Indicates failure in the PCA9557 bus BUS 7 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform th...

Страница 1208: ...st results for the DSA tape drive test The following messages can result when you run the DSA tape drive test 264 000 000 Tape Test Passed Tape Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 264 901 000 Tape Test Failed An error was found in the tape alert log Recoverable No S...

Страница 1209: ...2 000 Tape Test Failed Tape Test Failed Media is not detected Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at the latest level 4 Rerun the test after upgrading to the latest firmware...

Страница 1210: ...l of BMC IMM 264 904 000 Tape Test Failed Tape Test Failed Drive hardware error Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check the tape drive cabling for loose or broken connections or damage to the cable Replace the cable if damage is present 2 Clean the tape drive using the appropriate cleaning media and install ne...

Страница 1211: ... Diagnostic Event Log within the Firmware VPD section for this component 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Make sure that the drive firmware is at the latest level 6 Run the test again 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links Leno...

Страница 1212: ...g by symptom in the system Installation and Service Guide for the next corrective action Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM 264 907 000 Tape Test Failed An error was found in the block address somewhere Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using t...

Страница 1213: ...Complete the following steps 1 Make sure that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related links Lenovo Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic test results 1197 ...

Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...

Страница 1215: ...have installed new hardware or software in your environment check http www lenovo com serverproven to make sure that the hardware and software is supported by your product Go to http www lenovo com support to check for information to help you solve the problem Gather the following information to provide to the service technician This data will help the service technician quickly provide a solution...

Страница 1216: ...ovo com support The most current version of the product documentation is available in the following product specific Information Centers Flex System products http pic dhe ibm com infocenter flexsys information index jsp System x products http publib boulder ibm com infocenter systemx documentation index jsp NeXtScale System products http pic dhe ibm com infocenter nxtscale documentation index jsp ...

Страница 1217: ...anada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support IBM is Lenovo s preferred service provider for the System x Flex System and NeXtScale System products You can receive hardware service through your Lenovo reseller or from IBM To locate a reseller authorized by Lenovo to provide warranty service go to http www ibm com partnerworld and click Business Partner Locator For IBM suppo...

Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...

Страница 1219: ...ublication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo...

Страница 1220: ... all hard disk drive bays with the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to expresse...

Страница 1221: ...tered to 99 97 efficiency or greater using high efficiency particulate air HEPA filters that meet MIL STD 282 The deliquescent relative humidity of the particulate contamination must be more than 60 2 The room must be free of conductive contamination such as zinc whiskers Gaseous Copper Class G1 as per ANSI ISA 71 04 19853 Silver Corrosion rate of less than 300 Å in 30 days 1 ASHRAE 52 2 2008 Meth...

Страница 1222: ...the user may be required to take adequate measures European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2014 30 EU on the approximation of the laws of the Member States relating to electromagnetic compatibility Lenovo cannot accept responsibility for any failure to satisfy the protection requirements resulting fro...

Страница 1223: ...rmitätszeichen CE zu führen Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo Deutschland GmbH Meitnerstr 9 D 70563 Stuttgart Informationen in Hinsicht EMVG Paragraf 4 Abs 1 4 Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55032 Klasse A Nach der EN 55032 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkstörungen ve...

Страница 1224: ...rmonics guideline Japanese Statement of Compliance for Products More than 20A Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement 1208 System x3500 M5 Installation and Service Guide ...

Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...

Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...

Страница 1227: ...anager program 104 Business Partners instructions 23 button presence detection 17 C cable internal routing 33 cable connection 100 cache 3 call home feature Electronic Service Agent 144 call home tools 144 Canada Class A electronic emission statement 1206 caution statements 3 checkout procedure 128 performing 128 China Class A electronic emission statement 1209 Class A electronic emission notice 1...

Страница 1228: ...iagnostic program 9 DSA sending data 1200 DVD drive activity LED 16 drive DVD LED 16 eject button 16 DVD drive problems 145 DVD drive installation 54 207 DVD drive removal 207 Dynamic System Analysis 23 Dynamic System Analysis DSA Preboot diagnostics program 9 E electrical equipment servicing vii electrical input 3 electronic emission Class A notice 1206 Electronic Service Agent 144 embedded hyper...

Страница 1229: ...backplane 32 hot swap SAS or SATA removing 202 problems 147 status LED 16 types 68 199 200 hard disk drive installation 68 200 hard disk drive removal 199 202 hard disk drives hot swap SAS or SATA installation 70 203 hardware service and support telephone numbers 1201 hardware configuring 104 head output 3 heat sink retention module installation 286 heat sink retention module removal 285 heat sink...

Страница 1230: ...n 1 IP address for the IMM2 1 114 IPMI event log 9 139 140 IPMItool 140 J Japanese electromagnetic compatibility statements 1207 jumper UEFI boot recovery 160 jumpers system board 27 K Korea Class A electronic emission statement 1208 L LED ac power 19 dc power 19 DVD drive activity 16 Ethernet activity 17 19 Ethernet link status 19 hard disk drive activity 16 hard disk drive status 16 IMM2 heartbe...

Страница 1231: ...223 options installing 23 options installation completing 97 out of band 161 P particulate contamination 3 1205 parts listing 163 parts structural 174 PCI slot 1 19 slot 2 19 slot 3 19 slot 4 19 slot 5 19 slot 6 19 slot 7 19 slot 8 19 PCI expansion slots 3 People s Republic of China Class A electronic emission statement 1209 policy option 112 POST error codes 1017 event log 140 POST event log 139 ...

Страница 1232: ...e 207 fan 224 fan cage assembly 51 261 flash power module 220 flash power module holder 190 heat sink 270 heat sink retention module 285 hot swap hard disk drive 199 hot swap power supply 243 hypervisor flash device 259 left side cover 49 182 light path diagnostics assembly 230 memory modules 250 operator information panel assembly 248 optional ServeRAID adapter memory module 223 power cut off swi...

Страница 1233: ...are 111 statements and notices 3 static sensitive devices handling guidelines 31 structural parts 174 support web page custom 1201 SW4 switch block description 27 switch block 27 switches system board 27 symmetric multiprocessing 9 system error LED front 17 information LED 17 locator LED front 17 system board external connectors 26 internal connectors 25 LEDs 28 switches and jumpers 27 system boar...

Страница 1234: ...102 Systems Director 117 Systems Director IBM 117 Universal Unique Identifier UUID 119 USB connector 16 19 USB cable assembly installation 233 removal 232 using embedded hypervisor 115 integrated management module 112 Setup utility 107 the remote presence feature 113 using best practices to apply firmware and device driver updates 23 utility Setup 104 starting 107 using 107 V video connector rear ...

Страница 1235: ......

Страница 1236: ......

Отзывы: