Fan 1
Fan 2
Fan 3
Fan 4
Figure 40. The available fan sockets in the server
Note:
You can order the two additional fans for redundant cooling when only one microprocessor installed.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 29.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install a hot-swap fan, complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Step 2.
Touch the static-protective package that contains the hot-swap fan to any unpainted metal surface
on the server; then, remove the fan from the package.
Step 3.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 49).
Step 4.
Open the fan-locking handle on the replacement fan.
Step 5.
Insert the fan into the socket and close the fan-locking handle to the locked position.
53
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......