To find service bulletins that are available for the Lenovo System x3500 M5 server, go to
http://www.lenovo.com/support and search for
7383
, and
retain
.
Checkout procedure
The checkout procedure is the sequence of tasks that you should follow to diagnose a problem in the server.
About the checkout procedure
Before you perform the checkout procedure for diagnosing hardware problems, review the following
information.
• Read the safety information that begins on page “Safety” on page v.
•
Dynamic System Analysis (DSA) provides the primary methods of testing the major components of the
server, such as the system board, Ethernet controller, keyboard, mouse (pointing device), serial ports, and
hard disk drives. You can also use them to test some external devices. If you are not sure whether a
problem is caused by the hardware or by the software, you can use the diagnostic programs to confirm
that the hardware is working correctly.
• When you run DSA, a single problem might cause more than one error message. When this happens,
correct the cause of the first error message. The other error messages usually will not occur the next
time you run DSA.
Important:
If multiple error codes or light path diagnostics LEDs indicate a microprocessor error, the
error might be in the microprocessor or in the microprocessor socket. See “Microprocessor problems” on
page 150 for information about diagnosing microprocessor problems.
• Before you run DSA, you must determine whether the failing server is part of a shared hard disk drive
cluster (two or more servers sharing external storage devices). If it is part of a cluster, you can run all
diagnostic programs except the ones that test the storage unit (that is, a hard disk drive in the storage
unit) or the storage adapter that is attached to the storage unit. The failing server might be part of a
cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers sharing external storage
devices).
– One or more external storage units are attached to the failing server and at least one of the attached
storage units is also attached to another server or unidentifiable device.
– One or more servers are located near the failing server.
Important:
If the server is part of a shared hard disk drive cluster, run one test at a time. Do not run
any suite of tests, such as “quick” or “normal” tests, because this might enable the hard disk drive
diagnostic tests.
• If the server is halted and a POST error code is displayed, see Appendix B “UEFI (POST) error codes” on
page 1017. If the server is halted and no error message is displayed, see “Troubleshooting by symptom”
on page 145 and “Solving undetermined problems” on page 158.
• For information about power-supply problems, see “Solving power problems” on page 157, “Power
problems” on page 153, and “Power-supply LEDs” on page 137.
• For intermittent problems, check the event log; see “Event logs” on page 139 and Appendix C “DSA
diagnostic test results” on page 1041.
Performing the checkout procedure
Use this information to perform the checkout procedure.
To perform the checkout procedure, complete the following steps:
128
System x3500 M5 Installation and Service Guide
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......