Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix:
PLAT
ID:
0186
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
•
806f0113-0301xxxx : A bus timeout has occurred on system [ComputerSystemElementName].
(CPU 1 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130301xxxx or 0x806f01130301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0224
User Response
1. (Trained technician only)Reseat the microprocessor, and then restart the server.
2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
Appendix A. Integrated Management Module II (IMM2) error messages
501
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......