Step 5.
Connect one end of the battery/flash power module cable to the battery/flash power module
connector.
Step 6.
Route the remote battery/flash power module cable as shown in the following illustration.
ServeRAID adapter
Battery / flash power module
RAID adapter battery / flash
power module cable
Figure 141. Route the battery/flash power module
Attention:
Make sure that the cable is not connected and does not cover any connectors or
obstruct any components on the system board.
Step 7.
Install the battery/flash power module:
a.
Align the battery/flash power module cable to slot of the battery holder. Place the battery/flash
power module into the battery holder and make sure that the battery holder engages the
battery/flash power module securely.
1
2
Battery / flash power module
Battery holder
Retention clip
Figure 142. Align the battery/flash power module cable
Note:
The positioning of the remote battery/flash power module depends on the type of the
remote batteries/flash power module that you install.
b.
Lower and press down on the retention clip until it snaps in place to hold the battery/flash
power module firmly in place.
Step 8.
Reinstall the air baffle (see “Replacing the air baffle” on page 189).
222
System x3500 M5 Installation and Service Guide
Содержание System x3500 M5 Type 5464
Страница 1: ...System x3500 M5 Installation and Service Guide Machine Type 5464 ...
Страница 6: ...iv System x3500 M5 Installation and Service Guide ...
Страница 16: ...xiv System x3500 M5 Installation and Service Guide ...
Страница 140: ...124 System x3500 M5 Installation and Service Guide ...
Страница 194: ...178 System x3500 M5 Installation and Service Guide ...
Страница 1056: ...1040 System x3500 M5 Installation and Service Guide ...
Страница 1214: ...1198 System x3500 M5 Installation and Service Guide ...
Страница 1218: ...1202 System x3500 M5 Installation and Service Guide ...
Страница 1225: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1209 ...
Страница 1226: ...Taiwan BSMI RoHS declaration 1210 System x3500 M5 Installation and Service Guide ...
Страница 1235: ......
Страница 1236: ......