Goodrive100 inverters
Keypad operation procedure
IKR Aandrijven en Besturen
www.ikr-industries.nl
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
threshold
P04.26
Energy-saving
operation
selection
0:No operation
1:Automatic energy-saving operation
Motor on the light load conditions, automatically adjusts the
output voltage to save energy
0
◎
P04.27
Voltage Setting
Channel
selection
Select the output setting channel at V/F curve separation.
0: Keypad setting voltage: the output voltage is determined
by P04.28.
1:AI1 setting voltage
;
2:AI2 setting voltage
;
3:AI3 setting voltage
;
4:HDI1 setting voltage
;
5:Multi-stage speed setting voltage
;
6:PID setting voltage
;
7:MODBUS communication setting voltage
;
8~10: Reversed
Note: 100% corresponds to the rated voltage of the motor.
0
○