Function
code
Name
Detailed instruction of parameters
Default
value
Modify
0: Input phase loss protection disable
1: Input phase loss protection enable
LED tens:
0: Input phase loss protection disable
1: Input phase loss protection enable
P11.01
Sudden power
loss frequency
decreasing
function
selection
0: Enabled
1: Disabled
0
○
P11.02
frequency
decreasing
ratio of sudden
power loss
Setting range: 0.00Hz/s~P00.03 (the Max. frequency)
After the power loss of the grid, the bus voltage drops to the
sudden frequency-decreasing point, the inverter begin to
decrease the running frequency at P11.02, to make the
inverter generate power again. The returning power can
maintain the bus voltage to ensure a rated running of the
inverter until the recovery of power.
Voltage degree
230V
400V
660V
Frequency-decreasing
point of sudden power
loss
260V
460V
800V
10.00Hz/s
○