Goodrive100 inverters
Keypad operation procedure
IKR Aandrijven en Besturen
www.ikr-industries.nl
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
range 3
P08.15
Traverse range This function applies to the industries where traverse and
convolution function are required such as textile and
chemical fiber.
The traverse function means that the output frequency of the
inverter is fluctuated with the set frequency as its center. The
route of the running frequency is illustrated as below, of
which the traverse is set by P08.15 and when P08.15 is set
as 0, the traverse is 0 with no function.
Traverse range:The traverse running is limited by upper and
low frequency.
The traverse range relative to the center frequency: traverse
range AW
=
center frequency×traverse range P08.15.
Sudden jumping frequency
=
traverse range AW×sudden
jumping frequency range P08.16. When run at the traverse
frequency, the value which is relative to the sudden jumping
frequency.
The raising time of the traverse frequency: The time from the
lowest point to the highest one.
0.0%
○
P08.16
Sudden
jumping
frequency
range
0.0%
○
P08.17
Traverse boost
time
5.0s
○
P08.18
Traverse
declining time
5.0s
○