Goodrive100 inverters
Keypad operation procedure
IKR Aandrijven en Besturen
www.ikr-industries.nl
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
selection
2:Analog AI2 setting upper-limit frequency
3:Analog AI3 setting upper-limit frequency
4:Pulse frequency HDI setting upper-limit frequency
5:Multi-stage setting upper-limit frequency
6:MODBUS communication setting upper-limit frequency
7~9: Reserved
Note:setting method 1~9, 100% corresponds to the maximum
frequency
P03.15
Torque control
reverse
rotation upper-
limit frequency
keypad defined
value
0
○
P03.16
Torque control
forward
rotation upper-
limit frequency
keypad defined
value
This function is used to set the upper limit of the frequency.
P03.16 sets the value of P03.14; P03.17 sets the value of
P03.15.
Setting range:0.00 Hz~P00.03 (the Max. output frequency)
50.00 Hz
○
P03.17
Torque control
reverse
rotation upper-
limit frequency
keypad defined
value
50.00 Hz
○
P03.18
Electromotion
torque upper-
This function code is used to select the electromotion and
0
○