The procedure for configuring single-ended or dual-ended LM is as follows:
NOTE
All the steps must be performed on the MEP and RMEP unless otherwise specified.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
mpls-tp meg
meg-name
The maintenance entity group (MEG) view is displayed.
Step 3
Select one of the following sub-procedures as needed.
l
Configure single-ended frame LM.
1.
Run the
lost-measure single-ended receive enable
command to enable the RMEP to
receive LMMs from the MEP.
2.
Run any of the following commands:
–
Run the
loss-measure single-ended
[
interval
interval-value
|
count
count-value
|
exp
exp-value
]
*
command to enable single-ended on-demand frame LM on the
MEP.
–
Run the
lost-measure single-ended proactive
[
interval
interval-value
|
exp
exp-
value
]
*
command to enable single-ended proactive frame LM on the MEP.
–
(Optional) Run the
lost-measure single-ended loss-ratio
{
threshold1
threshold1-
value
|
sd1-continuous-period
period-length
|
sd1-period
period-value
sd1-
count
sd1-count-value
|
threshold2
threshold2-value
|
sd2-continuous-period
period-length
|
sd2-period
period-value
sd2-count
sd2-count-value
}
*
command
to set an alarm threshold for single-ended frame LM. When the number of dropped
frames reaches or exceeds the alarm threshold, an alarm is generated and an
automatic protection switching (APS) switchover is triggered.
–
(Optional) Run the
lost-measure single-ended loss-ratio revertive-period
revertive-period-value
command to set a threshold for an APS switchback. When
the number of times that the number of dropped frames falls below a specified alarm
threshold reaches or exceeds the configured threshold, an APS switchback is
triggered.
l
Configure dual-ended frame LM.
1.
(Optional) Run the
cc interval
interval-value
command to configure the interval
between CCM transmissions.
Typical CCM transmission intervals and their application scenarios are as follows:
–
3.3 ms: 300 frames are sent per second. This interval is recommended in protection
switching.
–
100 ms: 10 frames are sent per second. This interval is recommended in performance
monitoring.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
9 MPLS-TP OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
933