![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 688](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453688.webp)
l
Configure basic BFD functions.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
oam-mgr
The OAM management view is displayed.
Step 3
Perform either of the following configurations as required.
l
Unidirectional association
Run the
oam-bind ingress efm interface
interface-type
interface-number
egress
bfd-
session
bfd-session-id
command to configure EFM to notify BFD of faults.
Run the
oam-bind ingress bfd-session
bfd-session-id
egress
efm
interface
interface-type
interface-number
command to configure BFD to notify EFM of faults.
l
Bidirectional association
Run the
oam-bind efm interface
interface-type
interface-number
bfd-session
bfd-session-
id
command to configure EFM and BFD to notify each other of faults.
NOTE
The functions of two commands used to configure association functions in opposite directions are the same
as those of one command used to configure the bidirectional association function.
If the
oam-bind efm interface
interface-type
interface-number
bfd-session
bfd-session-id
command is
run, the
oam-bind ingress efm interface
interface-type
interface-number
egress
bfd-session
bfd-session-
id
and
oam-bind ingress bfd-session
bfd-session-id
egress
efm
interface
interface-type
interface-
number
commands will be displayed in the configuration file.
----End
Configuring Association Between EFM and MPLS OAM
If EFM is deployed at the user side and MPLS OAM is deployed at the network side of a device,
association between EFM and MPLS OAM can be configured. This allows EFM and MPLS
OAM to notify each other of faults and ensures reliable service transmission.
Context
For details on the principles and usage scenarios of association between EFM and MPLS OAM,
see
Association Between EFM and Detection Protocols
.
Association between EFM and MPLS OAM is bidirectional. The details are as follows:
l
When EFM detects a link fault, it will notify MPLS OAM of the fault.
l
When MPLS OAM detects a link fault, it will notify EFM of the fault.
Pre-configuration Tasks
Before configuring association between EFM and MPLS OAM, complete the following tasks:
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
671