![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 560](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453560.webp)
Step 3
Verify the configuration.
Run the
display cfm remote-mep
command on the CE. The command output shows that the
remote MEP is Up.
[CE]
display cfm remote-mep
The total number of RMEPs is : 2
The status of RMEPS : 2 up, 0 down, 0 disable
--------------------------------------------------
MD Name : md
Level : 0
MA Name : ma
RMEP ID : 2
VLAN ID : 2
VSI Name : --
L2VC ID : --
MAC : 0018-82d4-04c3
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status : up
Alarm Status : none
Interface TLV : disabled
MD Name : md
Level : 0
MA Name : ma
RMEP ID : 3
VLAN ID : 2
VSI Name : --
L2VC ID : --
MAC : 0018-8267-7f7d
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status : up
Alarm Status : none
Interface TLV : disabled
Connect Status : up
Run the
display cfm remote-mep
command on PE3. The command output shows that the remote
MEP is Up.
[PE3]
display cfm remote-mep
The total number of RMEPs is : 2
The status of RMEPS : 2 up, 0 down, 0 disable
--------------------------------------------------
MD Name : md
Level : 0
MA Name : ma
RMEP ID : 1
VLAN ID : --
VSI Name : --
L2VC ID : --
MAC : --
CCM Receive : enabled
Trigger-If-Down : disabled
CFM Status : up
Alarm Status : none
Interface TLV : disabled
Connect Status : up
MD Name : md
Level : 0
MA Name : ma
RMEP ID : 3
VLAN ID : --
VSI Name : --
L2VC ID : --
MAC : --
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
543