![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 693](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453693.webp)
[CE1]
display efm session all
Interface EFM State Loopback Timeout
----------------------------------------------------------------------
GigabitEthernet1/0/2 detect --
If the link is working properly, perform the following operations to monitor the link in real time.
Step 7
Configure errored symbol detection, errored frame detection, and errored frame second
detection.
# Configure errored symbol detection on GE 1/0/2 of CE1.
[CE1]
interface gigabitethernet 1/0/2
[CE1-GigabitEthernet1/0/2]
efm error-frame period 5
[CE1-GigabitEthernet1/0/2]
efm error-frame threshold 5
[CE1-GigabitEthernet1/0/2]
efm error-frame notification enable
# Configure errored frame detection on GE 1/0/2 of CE1.
[CE1-GigabitEthernet1/0/2]
efm error-code period 5
[CE1-GigabitEthernet1/0/2]
efm error-code threshold 5
[CE1-GigabitEthernet1/0/2]
efm error-code notification enable
# Configure errored frame second detection on GE 1/0/1 of CE1.
[CE1-GigabitEthernet1/0/2]
efm error-frame-second period 120
[CE1-GigabitEthernet1/0/2]
efm error-frame-second threshold 5
[CE1-GigabitEthernet1/0/2]
efm error-frame-second notification enable
[CE1-GigabitEthernet1/0/2]
quit
Step 8
Verify the configuration.
If the preceding configurations are complete, GE 1/0/2 of CE1 and GE 2/0/1 of CE4 will enter
the handshake phase. Run the
display efm session
{
all
|
interface
interface-type
interface-
num
} command on CE1 or CE4. The command output shows that the EFM state is
detect
on
GE 1/0/2 or GE 2/0/1.
[CE1]
display efm session interface gigabitethernet 1/0/1
Interface EFM State Loopback Timeout
----------------------------------------------------------------------
GigabitEthernet1/0/2 detect --
After the preceding configuration is complete, run the
display efm
{
all
|
interface
interface-
type
interface-number
} command to display EFM configurations.
[CE1]
display efm interface gigabitethernet 1/0/2
Item Value
----------------------------------------------------
Interface: GigabitEthernet1/0/2
EFM Enable Flag: enable
Mode: active
Loopback IgnoreRequest: no
OAMPDU MaxSize: 128
OAMPDU Timeout: 5000
OAMPDU Interval: 1000
ErrCodeNotification: enable
ErrCodePeriod: 5
ErrCodeThreshold: 5
ErrFrameNotification: enable
ErrFramePeriod: 5
ErrFrameThreshold: 5
ErrFrameSecondNotification: enable
ErrFrameSecondPeriod: 120
ErrFrameSecondThreshold: 5
Hold Up Time: 0
ThresholdEvtTriggerErrDown: disable
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
676