44263
Minimum delay(usec) : -1803127 Minimum delay variation(usec) : 0
----End
Configuration Files
l
Configuration file of CE1
#
sysname CE1
#
vlan batch 2
#
cfm version standard
cfm enable
#
interface GigabitEthernet1/0/1
portswitch
undo shutdown
port trunk allow-pass vlan 2
#
cfm md md3
ma ma3
map vlan 2
mep mep-id 3 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 3 enable
remote-mep mep-id 4
remote-mep ccm-receive mep-id 4 enable
delay-measure one-way continual send mep 3 remote-mep 4 interval 1000
#
return
l
Configuration file of CE2
#
sysname CE2
#
vlan 2
#
cfm version standard
cfm enable
#
interface GigabitEthernet1/0/1
portswitch
undo shutdown
port trunk allow-pass vlan 2
#
cfm md md3
ma ma3
map vlan 2
mep mep-id 4 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 4 enable
remote-mep mep-id 3
remote-mep ccm-receive mep-id 3 enable
delay-measure one-way receive mep 4
delay-measure one-way continual receive mep 4
#
return
Example for Configuring Two-way Frame Delay Measurement in VLL Networking
This section provides an example showing how to configure two-way frame delay measurement
in VLL networking.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
858