The MEP is enabled to receive CCMs from the RMEP in the same MA.
l
Perform the following steps on the CE:
1.
Run:
system-view
The system view is displayed.
2.
Run:
cfm md
md-name
[
level
level
]
An MD is created and the MD view is displayed.
3.
Run:
ma
ma-name
An MA is created and the MA view is displayed.
4.
Run:
map
vlan
vlan-id
The MA is bound to a VLAN.
5.
Run:
mep mep-id
mep-id
interface-type interface-number
outward
A MEP is created.
6.
Run:
remote-mep
mep-id
mep-id
[
mac
mac-address
]
An RMEP is created in the MA.
7.
Run:
mep ccm-send
[
mep-id
mep-id
]
enable
The MEP is enabled to send CCMs.
8.
Run:
remote-mep ccm-receive
[
mep-id
mep-id
]
enable
The MEP in the MA is enabled to receive CCMs sent by the RMEP in the same MA.
----End
Configuring Ethernet CFM on the Switch and Remote PE
Run Ethernet CFM between the switch and remote PE to check connectivity by exchanging
CCMs. In addition, MAC ping and MAC trace can be performed.
Context
The detailed configuration is similar to that in
Configuring Ethernet CFM on the CE and
, and is not mentioned here.
NOTE
l
The MA configured on the remote PE must be associated with a VSI, and the type of the MEP must
be inward-facing.
l
The rule for creating the MIP needs to be configured on transit nodes.
For the rule for creating the MIP, see
.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
523