![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 1095](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_1694531095.webp)
[CSG-Tunnel1/0/2]
mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
3.3.3.3 tunnel-id 200
[CSG-Tunnel1/0/2]
mpls te commit
[CSG-Tunnel1/0/2]
quit
# Configure RSG1.
[RSG1]
interface tunnel 1/0/1
[RSG1-Tunnel1/0/1]
mpls te bit-error-detection
[RSG1-Tunnel1/0/1]
mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
1.1.1.1 tunnel-id 100
[RSG1-Tunnel1/0/1]
mpls te commit
[RSG1-Tunnel1/0/1]
quit
# Configure RSG2.
[RSG2]
interface tunnel 1/0/2
[RSG2-Tunnel1/0/2]
mpls te bit-error-detection
[RSG2-Tunnel1/0/2]
mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
1.1.1.1 tunnel-id 200
[RSG2-Tunnel1/0/2]
mpls te commit
[RSG2-Tunnel1/0/2]
quit
b.
Configure bit-error-triggered PW switching.
# Configure bit-error-triggered PW switching on the AC interface of the CSG.
[CSG]
interface gigabitethernet 1/0/2.10
[CSG-GigabitEthernet1/0/2.10]
mpls l2vpn pw bit-error-detection
[CSG-GigabitEthernet1/0/2.10]
quit
# Configure bit error detection to trigger PW switchovers on the AC interface of RSG1.
[RSG1]
interface eth-trunk 10.1
[RSG1-Eth-Trunk10.1]
mpls l2vpn pw bit-error-detection
# Configure bit error detection to trigger PW switchovers on the AC interface of RSG2.
[RSG2]
interface eth-trunk 10.1
[RSG2-Eth-Trunk10.1]
mpls l2vpn pw bit-error-detection
NOTE
This example shows how to configure bit-error-triggered single-segment (SS)-PW switching. To
configure bit-error-triggered multi-segment (MS)-PW switching, you also need to run the
mpls
switch-l2vc
ip-address
vc-id
between
ip-address
vc-id
encapsulation
encapsulation-type
bit-
error-detection
command to enable bit-error-triggered protection switching on superstratum
provider edges (SPEs).
8.
Verify the configuration.
# Run the
display bfd bit-error-detection session all
command on the CSG to view BFD
bit error information.
[CSG]
display bfd bit-error-detection session all
------------------------------------------------------------------------------
--
BFD Bit Error
Information:
------------------------------------------------------------------------------
--
Session MIndex :
512
Session Type :
PE
FSM Board Id :
1
Fault Type :
-
Min Tx Interval (ms) :
1000
Max Tx Interval (ms) :
30000
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
10 Bit-Error-Triggered Protection Switching Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1078