![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 889](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453889.webp)
[CE2]
cfm md md3
[CE2-md-md3]
ma ma3
[CE2-md-md3-ma-ma3]
delay-measure two-way receive mep 4
[CE2-md-md3-ma-ma3]
quit
[CE2-md-md3]
quit
3.
Enable on-demand two-way frame delay measurement.
# Configure CE1.
[CE1]
cfm md md3
[CE1-md-md3]
ma ma3
[CE1-md-md3-ma-ma3]
delay-measure two-way send mep 3 remote-mep 4 interval
1000 count 20
[CE1-md-md3-ma-ma3]
quit
[CE1-md-md3]
quit
4.
Verify the configuration.
# After completing the configuration, run the
display y1731 statistic-type twoway-delay
md md3 ma ma3
command to view actual on-demand two-way frame delay measurements
on CE2.
<CE1>
display y1731 statistic-type twoway-delay md md3 ma ma3
Latest two-way delay statistics:
------------------------------------------------------------------------------
--
Index Delay(usec) Delay variation(usec)
------------------------------------------------------------------------------
--
1 0 -
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
------------------------------------------------------------------------------
--
Average delay(usec) : 0 Average delay variation(usec) : 0
Maximum delay(usec) : 0 Maximum delay variation(usec) : 0
Minimum delay(usec) : 0 Minimum delay variation(usec) : 0
Step 2
Configure proactive two-way frame delay measurement for links between CEs.
NOTE
Proactive two-way frame delay measurement within a specified VLAN allows you to collect link
measurement statistics continuously over a long term.
1.
Enable proactive two-way frame delay measurement.
# Configure CE1.
[CE1]
cfm md md3
[CE1-md-md3]
ma ma3
[CE1-md-md3-ma-ma3]
delay-measure two-way continual send mep mep-id 3 remote-
mep 4 interval 30000
[CE1-md-md3-ma-ma3]
quit
[CE1-md-md3]
quit
2.
Verify the configuration.
# After completing the configuration, run the
display y1731 statistic-type twoway-delay
md md3 ma ma3
command to view actual proactive two-way frame delay measurements
on CE2.
<HUAWEI>
display y1731 statistic-type twoway-delay md md3 ma ma3
Latest two-way delay statistics:
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
872